Delete Master Users

5

Activate the lock;

a

Input 0 and #;

b

1

2

3

4

5

6

7

8

9

0

#

1

2

3

4

5

6

7

8

9

0

#

0

#

+

Input the master user 
for authorization;

c

1

2

3

4

5

6

7

8

9

0

#

***

Master

Input 1 for master user setting

d

1

2

3

4

5

6

7

8

9

0

#

1

Input 3 to delete master user

e

1

2

3

4

5

6

7

8

9

0

#

3

Input the ID number, and then 
press # to confirm to delete it.  

f

ID

#

+

Please try to use the deleted user to unlock and make sure 
the operations are successful. 

Содержание M600

Страница 1: ...M600 FINGERPRINT DOOR LOCK ...

Страница 2: ...en Keypad Mechanical Key Battery Knob 1 There are 4 kinds of unlocking methods available in this lock 2 The password can be 6 to 10 digits combination among 0 to 9 Fingerprint Unlocking 100 users Password Unlocking 50 users RF Card Unlocking 200 users Mechanical keys are used for emergency access ...

Страница 3: ...ew Install the connection rods on the front panel There are marks on the spindle hole for Left handle put the L mark on the right side for Right handle put the R mark on the right side 5 take down the battery case and install the batteries 4 Install the front panel on the door 2 1 5V 1 5V 1 5V 1 5V 6 Install the back panel and fasten the screws with the front panel After that test the installation...

Страница 4: ...k a Input 0 and b 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 3 0 Input the default master password and press to confirm c 1 2 3 4 5 6 7 8 9 0 Master Input 1 for master user setting d 1 2 3 4 5 6 7 8 9 0 1 Input 1 to add master user e 1 2 3 4 5 6 7 8 9 0 1 ...

Страница 5: ...er The default master password is 01234 56789 once a new master user is registered in the lock it will be replaced by the new master user and cannot be used any more The password can be 6 to 10 digits Once the registration is finished please try to use the registered user to unlock and confirm the registration is successful It is suggested to make a record list for the user ID and manager them bette...

Страница 6: ...2 3 4 5 6 7 8 9 0 1 1 Fingerprint User place the fingerprint on the sensor 3 times to register X3 2 Password User input the password and press to confirm in 2 times X2 3 Card User place the card on the card reader to register The password can be 6 to 10 digits Once the registration is finished please try to use the registered user to unlock and confirm the registration is successful It is suggested to...

Страница 7: ...n c 1 2 3 4 5 6 7 8 9 0 Master Input 1 for master user setting d 1 2 3 4 5 6 7 8 9 0 1 Input 2 to modify master user e 1 2 3 4 5 6 7 8 9 0 2 Once the registration is finished please try to use the registered user to unlock and confirm the registration is successful Input the new password and confirm with f NEW Input the new password and confirm with again to finish NEW g ...

Страница 8: ...4 5 6 7 8 9 0 Master Input 2 for normal user setting d 1 2 3 4 5 6 7 8 9 0 2 Input 2 to modify normal user e 1 2 3 4 5 6 7 8 9 0 2 Input the new password and confirm with f NEW 1 2 3 4 5 6 7 8 9 0 Input the new password and confirm with again to finish g NEW Once the registration is finished please try to use the registered user to unlock and confirm the registration is successful ...

Страница 9: ...t the master user for authorization c 1 2 3 4 5 6 7 8 9 0 Master Input 1 for master user setting d 1 2 3 4 5 6 7 8 9 0 1 Input 3 to delete master user e 1 2 3 4 5 6 7 8 9 0 3 Input the ID number and then press to confirm to delete it f ID Please try to use the deleted user to unlock and make sure the operations are successful ...

Страница 10: ...t the master user for authorization c 1 2 3 4 5 6 7 8 9 0 Master Input 2 for normal user setting d 1 2 3 4 5 6 7 8 9 0 2 Input 3 to delete normal user e 1 2 3 4 5 6 7 8 9 0 3 Input the ID number and then press to confirm to delete it f ID Please try to use the deleted user to unlock and make sure the operations are successful ...

Страница 11: ... 4 Input 1 for date and time setting e 1 2 3 4 5 6 7 8 9 0 Input the date and time by Year Month Day HH MM f 1 YY MM DD HH MM There are 2 digits available for the date which means you only can input 2 digits for the year month and day For example 2019 will be 19 March will be 03 first day will be 01 The time is 24 hours format For example 2 00 PM will be 14 00 Please update the time to the current ...

Страница 12: ...7 8 9 0 0 Input the master user for authorization c 1 2 3 4 5 6 7 8 9 0 Input 4 for system setting d 1 2 3 4 5 6 7 8 9 0 4 Input 2 for sound volume setting e 1 2 3 4 5 6 7 8 9 0 Use number 1 to turn down the volume and use number 3 to turn up the volume and press to confirm f 2 1 3 11 Master ...

Страница 13: ...3 4 5 6 7 8 9 0 Enable input 2 and confirm with f 4 If you need a higher security to protect the password you can activate the random password protection Under this protection you can input some number before and behind the real password however during you are inputting the real password you have to input the full correct password 1 2 3 4 5 6 7 8 9 0 2 Disable input 1 and confirm with g 1 2 3 4 5 6 ...

Страница 14: ... system setting d 1 2 3 4 5 6 7 8 9 0 4 If you need a higher security for unlocking you can switch the lock into double unlocking mode which the lock requires 2 registered users to unlock every time Input 3 for double unlocking mode e 1 2 3 4 5 6 7 8 9 0 Enable input 2 and confirm with f 1 2 3 4 5 6 7 8 9 0 2 Disable input 1 and confirm with g 1 2 3 4 5 6 7 8 9 0 1 3 13 Master ...

Страница 15: ...b 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 Use the register user to unlock and it will cancel the passage mode a 1 2 3 4 5 6 7 8 9 0 When the lock is requested for unlocking frequently you can activate the passage mode and let the people unlocking without identifications Enable 2 8 Disable 14 Register ...

Страница 16: ...5 6 7 8 9 0 Input 4 for system setting d 1 2 3 4 5 6 7 8 9 0 4 Input 5 to reset the lock e 1 2 3 4 5 6 7 8 9 0 Input 1 to confirm and the lock start to reset to factory default f 5 1 2 3 4 5 6 7 8 9 0 1 Make sure the lock has enough power before operation Please register the master user for the lock as soon as possible after the lock is restored 15 Master ...