Avenger 110009 Скачать руководство пользователя страница 32

200288-01

Rev. D

10/17

WARRANTY

KEEP THIS WARRANTY

Model 

 _______________________________

Serial No.  ____________________________

Date Purchased 

 _______________________

Keep receipt for warranty verification.

REGISTER YOUR PRODUCT AT WWW.FACTORYBUYSDIRECT.COM

FACTORY BUYS DIRECT LIMITED WARRANTIES

New Products

Standard Warranty:

 Factory Buys Direct warrants this new product and any parts thereof to be free from 

defects in material and workmanship for a period of one (1) year from the date of first purchase from an 

authorized dealer provided the product has been installed, maintained and operated in accordance with 

Factory Buys Direct’s warnings and instructions.
For products purchased for commercial, industrial or rental usage, this warranty is limited to 90 days from 

the date of first purchase.

Factory Reconditioned Products

Limited Warranty:

 Factory Buys Direct warrants factory reconditioned products and any parts thereof to be 

free from defects in material and workmanship for a period 30 days from the date of first purchase from an 

authorized dealer provided the product has been installed, maintained and operated in accordance with Factory 

Buys Direct’s warnings and instructions. No return will be authorized. Parts will be provided to repair the product.

Terms Common to All Warranties

The following terms apply to all of the above warranties:
Always specify model number and serial number when contacting the manufacturer. To make a claim under 

this warranty, the bill of sale or other proof of purchase must be presented.
This warranty is extended only to the original retail purchaser when purchased from an authorized dealer, 

and only when installed by a qualified installer in accordance with all local codes and instructions furnished 

with this product.
This warranty covers the cost of part(s) required to restore this product to proper operating condition and 

an allowance for labor when provided by a Factory Buys Direct Authorized Service Center or a provider ap-

proved by Factory Buys Direct. Warranty parts must be obtained through authorized dealers of this product 

and/or Factory Buys Direct who will provide original factory replacement parts. Failure to use original factory 

replacement parts will void this warranty.
Traveling, handling, transportation, diagnostic, material, labor and incidental costs associated with warranty 

repairs, unless expressly covered by this warranty, are not reimbursable under this warranty and are the 

responsibility of the owner.
Excluded from this warranty are products or parts that fail or become damaged due to misuse, accidents, 

improper installation, lack of proper maintenance, tampering or alteration(s).
This is Factory Buys Direct’s exclusive warranty, and to the full extent allowed by law; this express warranty 

excludes any and all other warranties, express or implied, written or verbal and limits the duration of any 

and all implied warranties, including warranties of merchantability and fitness for a particular purpose to one 

(1) year on new products and 30 days on factory reconditioned products from the date of first purchase. 
Factory Buys Direct makes no other warranties regarding this product.
Factory Buys Direct’s liability is limited to the purchase price of the product and Factory Buys Direct shall not 

be liable for any other damages whatsoever under any circumstances including direct, indirect, incidental, 

or consequential damages.
Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of 

incidental or consequential damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. 

Factory Buys Direct.com

2701 Industial Drive

Bowling Green, KY 42101

1-855-607-6557

Содержание 110009

Страница 1: ...plier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied installer service agency or the gas supplier WARNING This...

Страница 2: ...this manual WARNING Improper installation adjustment al teration service or maintenance can cause injury or property damage Refer to this manual for correct in stallation and operational procedures F...

Страница 3: ...ve heater serviced Some people are more af fected by carbon monoxide than others These include pregnant women people with heart or lung disease or anemia those under the influ ence of alcohol and thos...

Страница 4: ...ing Only a qualified service person should service and repair heater 10 Operating heater above elevations of 4 500 feet could cause pilot outage 11 To prevent performance problems do not use propane f...

Страница 5: ...VAC 60 Hz Note Dimensions listed are outer most points on the heater includes control knobs and grill For purposes of input adjustment LOCAL CODES Install and use heater with care Follow all local cod...

Страница 6: ...PRODUCT OF UNVENTED ROOM HEATERS Water vapor is a by product of gas combus tion An unvented room heater produces ap proximately one 1 ounce 30 mL of water for every 1 000 BTUs 0 3 KWs of gas input per...

Страница 7: ...o breathe Fresh air must enter your home All fuel burning ap pliances need fresh air for proper combustion and ventilation Exhaust fans fireplaces clothes dryers and fuel burning appliances draw air f...

Страница 8: ...ation grills or ducts You must provide two perma nent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directly to the outdoors or spaces open to the outdoors T...

Страница 9: ...arances as Viewed From Front of Heater CAUTION This heater cre ates warm air currents These currents move heat to wall sur faces next to heater Installing heater next to vinyl or cloth wall coverings...

Страница 10: ...mounting bracket is located on back panel of heater It has been taped there for shipping Remove mounting bracket from back panel Methods For Attaching Mounting Bracket To Wall Use only the last hole...

Страница 11: ...nsert mounting screws through bracket and into wall studs 4 Tighten screws until mounting bracket is firmly fastened to wall studs Attaching to Wall Anchor Method For attaching mounting bracket to hol...

Страница 12: ...s firmly secured to wall Do not over tighten Note Do not replace front panel at this time Replace front panel after making gas connec tions and checking for leaks Figure 10 Mounting Heater Onto Mounti...

Страница 13: ...tion fitting is inserted and tightened this plunger will be pushed back by the fitting making all of the adjustments for the gas being supplied DO NOT REMOVE THE PLUNGER The regulator will not work Th...

Страница 14: ...he connection fitting While pushing in rotate the fitting clockwise until the threads engage the regulator After the fitting has been hand tightened into the regulator use a wrench to complete tighten...

Страница 15: ...r between the heater and gassupply Gassupplierprovides externalregulatorfornaturalgas Theinstallerprovidestheexternal regulator for propane gas CAUTION Avoid damage to regulator Hold gas regulator wit...

Страница 16: ...al Regulator with Vent Pointing Down Propane Supply Tank Equipment Shutoff Valve Ground Joint Union 3 8 NPT Pipe Nipple Tee Joint Reducer Bushing to 1 8 NPT 1 8 NPT Plug Tap Test Gauge Connection Sedi...

Страница 17: ...once 6 Light heater see Lighting Instructions on page 18 Check all other internal joints for leaks 7 Turn off heater see To Turn Off Gas Ap pliance page 19 8 Replace front panel 1 Open equipment shut...

Страница 18: ...ation above 2 Make sure equipment shutoff valve is fully open 3 Turn control knob clockwise to the OFF position 4 Wait five 5 minutes to clear out any air Then smell for gas including near the floor I...

Страница 19: ...ons page 18 3 With control knob pressed in strike match Hold match to pilot until pilot lights 7 Keep control knob pressed in for 30 sec onds after lighting pilot After 30 seconds release control knob...

Страница 20: ...ectrical Code and for US instal lations the National Electrical Code ANSI NFPA NO 70 WARNING If repairing or replacing any electrical compo nent or wiring the original wire routing colorcodingandsecur...

Страница 21: ...uple to cool which shuts the heater off If pilot flame pattern is incorrect as shown in Figure 25 turn heater off see To Turn Off Gas to Ap pliance page 19 see Troubleshooting pages 23 through 26 WARN...

Страница 22: ...minutes 2 Remove four screws securing front panel 3 Pull front panel forward 4 Inspect burner and pilot for dust and dirt 5 Blow air through the ports slots and holes in the burner 6 Replace front pa...

Страница 23: ...ar ing life and require no further lubrication However periodic cleaning vacuuming of the appliance around the air intake and exhaust as well as the fan heater is recommended For heavy or continuous u...

Страница 24: ...utoff valve 2 Fully press in control knob while pressing ignitor button 3 Continue holding down con trol knob Repeat igniting op eration until air is removed 4 Clean ODS pilot see Care and Maintenance...

Страница 25: ...is lit 1 Burner orifice is clogged 2 Inlet gas pressure is too low 1 Clean burner orifice see Care and Maintenance page 22 2 Contact local gas supplier Delayed ignition of burner s 1 Manifold pressure...

Страница 26: ...similar products Heater produces un wanted odors 1 Heater is burning vapors from paint hair spray glues etc See IMPORTANTstatement page23 2 Gas leak See Warning State ment at the top of page 23 3 Low...

Страница 27: ...at 1 855 607 6557 for referral information When calling Customer Service or your dealer have ready Your name Your address Model and serial number of your heater How heater was malfunctioning Type of g...

Страница 28: ...www factorybuysdirect com 200288 01D 28 PARTS MODEL FDT10BFA 110009 2 11 3 9 8 7 1 15 10 5 6 14 13 4 12...

Страница 29: ...1132 01 Mounting Bracket 1 3 161133 01 Piezo Ignitor 1 4 161130 01 Thermostat Valve Assembly 1 5 Burner Assembly 1 6 161139 02 ODS Pilot 1 7 Safety Dual Fuel Regulator 1 8 161200 01 Inlet Cover Plug 1...

Страница 30: ...factorybuysdirect com 200288 01D 30 PARTS MODELS FDT20BFA 110010 AND FDT30BFA 110011 2 11 3 9 8 7 1 12 10 5 6 14 13 12 4 16 15 FDT20BFA Shown Available as an accessory only Available as an accessory o...

Страница 31: ...01 161133 01 Piezo Ignitor 1 4 161130 01 161130 01 Thermostat Valve Assy 1 5 Burner Assembly 1 6 161139 01 161139 01 ODS Pilot 1 7 Dual Fuel Regulator 1 8 161200 01 161200 01 Inlet Cover Plug 1 9 160...

Страница 32: ...of part s required to restore this product to proper operating condition and an allowance for labor when provided by a Factory Buys Direct Authorized Service Center or a provider ap proved by Factory...