The unit pulls air out for 70 seconds, then it pushes air in for the same time.

When heated air is pulled (extracted) from inside the room, it warms up the heat exchanger; 

when the cold air is pushed (supplied) in the room, it gets preheated, recovering most of 

thermal energy which would be otherwise lost in the ventilation process.

The unit runs at the speed selected by activating the switches “S1”, “S2” and “S3” of the 

441001K3RC, 442001K3RC,443001K3RC (accessory Fig. 57). The same functionality 

can be achieved with 441001K3RC, 442001K3RC,443001K3RC or with 3 switches NO.

VERSIONS

OPERATION

STANDARD

External grille in high quality, impact and UV-resistant ABS colour RAL 9010 with anti-

insect net.

• If the environment in which the product is installed also houses a fuel-operating device 

(water heater, methane stove etc., that is not a “sealed chamber” type), it is essential 

to  ensure  adequate  air  intake,  to  ensure  good  combustion  and  proper  equipment 

operation.

• Inner ventilation unit material: high quality, impact and UV-resistant ABS colour RAL 9010.

• Design front cover removable for cleaning without the use of tools.

•Easy maintenance installation plate, for easy access to the heat exchanger from inside 

the room.

• Anti-dust filter, easily removable for washing by the user without tools.

• Regenerative honeycombs ceramic heat exchanger.

• External grille in high quality, impact and UV-resistant ABS colour RAL 9010 with anti-

insect net.

• High efficiency aerodynamic fan with “winglet” blades to optimise quietness and efficiency.

• Single phase EC reversible Brushless motor with integral thermal protection.

• Motor mounted on high quality ball bearings.

• The unit is double insulated: no earth connection is required.

• Trickle speed selectable. 

• Free-cooling (Bypass) mode.

• IPX4 degree of protection.

• Power supply 220V to 240V~ 50Hz.

TECHNICAL SPECIFICATIONS

The unit should operate continuously, and only stopped for maintenance or service.

When  heat  exchange  is  not  useful  (for  example  in  mid-seasons  when  indoor  and 

outdoor temperatures are similar), or when heat exchange is not recommended (for 

example with the option “summer free cooling”), it is recommended to set the unit in 

“extract-only” or “intake-only” mode and NOT to switch it off.

INTRODUCTION

Solitair is a single alternate flow decentralized (single point) residential heat recovery unit, 

also  called  «push&pull»  unit,  designed  to  ensure  adequate  ventilation  in  enclosed 

environments without energy losses and designed to be installed in ambients like living 

room and bedrooms.

It is recommended that two units are installed in pair: when one unit is pulling, the other 

is pushing. Pair of units can be installed in the same room or in different rooms (i.e. 

livingroom and bedroom). The unit is suitable for installation on an outside wall.

Model

Airflow m

3

/h 

Power W 

Weight Kg

VNRD100EC

10/15/25

1,2/1,7/2,6

2,3

VNRD150EC

20/40/60

1,4/2,3/3,8

4,2

Содержание VNRD100EC

Страница 1: ...to il prodotto deve essere conforme alle normative vigenti Prima di collegare il prodotto alla rete di alimentazione o alla presa elettrica accertarsi che i dati di targa tensione e frequenza siano ri...

Страница 2: ...iatore di calore dall interno della stanza Filtro anti polvere lavabile removibile dall interno da parte dell utente senza l ausilio di utensili Scambiatore di calore rigenerativo con pacco ceramico G...

Страница 3: ...42079 443079 441068RL 442068RL 443068RL o Sensore RG1 CO2 connettendolo in parallelo al devitatore S2 Schema di collegamento singola unit Fig 18A Schema di collegamento con sensori ambiente Fig 18B 18...

Страница 4: ...onformit alle norme e regolamenti locali in vigore assicurandosi che l interruttore generale dell impianto sia spento Pag 15 La pulizia dello scambiatore pu essere effettuata anche dall esterno MANUTE...

Страница 5: ...ontact a quali ed technician The device should not be used as an activator for water heaters stoves etc nor should it discharge into hot air fume vent ducts deriving from any type of combustion unit I...

Страница 6: ...le in high quality impact and UV resistant ABS colour RAL 9010 with anti insect net High ef ciency aerodynamic fan with winglet blades to optimise quietness and ef ciency Single phase EC reversible Br...

Страница 7: ...ntegral jumper set in position A Fig 20A means extract mode Intergal jumper set in position B Fig 20B means intake mode The jumper position defines both the air flow direction when the unit is activat...

Страница 8: ...xternal grille Versione standard Standard version 270 510 164 q 164 q 108 O mm B VNRD100EC VNRD150EC A 164 218 B 46 51 C 164 218 D 270 510 300 560 E 108 158 DIMENSIONI DIMENSIONS mm INSTALLAZIONE INST...

Страница 9: ...9 4 5 schiuma d isolamento insulation foam 6 7 8 9 5x40mm 8x10mm 10 11 100mm VNRD100EC 115mm VNRD150EC...

Страница 10: ...10 12 13 14 15 16 17 18A 18A...

Страница 11: ...CO2 0 2 1 3 L L L 1 1 1 18B S 3 S 2 S 1 G N D N L CTRL S S1 S2 S3 II I L L L 1 1 1 N L HY CO2 0 1 2 3 18C 18D UNIT 1 UNIT 2 18E 18F VELOCITA FISSA 1 SPEED 1 FIXED VELOCITA FISSA 2 SPEED 2 FIXED S 3 S...

Страница 12: ...12 JUMPER POSITION A 20A ESTRAZIONE EXTRACT 23 CLICK 21 JUMPER POSITION B 20B IMMISSIONE INTAKE 22 24 25 26...

Страница 13: ...13 27 5x40mm 3 5mm 29 28 30B GRIGLIA ESTERNA EXTERNAL GRILLE 30A RESET DELLA SINCRONIZZAZIONE DELLE UNITA OPZIONE 1 31 TO RESET OF THE SYNCHRONIZATION OF THE UNITS OPTION 1...

Страница 14: ...LIZIA FILTRO MANUTENZIONE ORDINARIA Pu essere eseguita dall utente Can be carried out by the user RESET DELLA SINCRONIZZAZIONE DELLE UNITA OPZIONE 2 TO RESET OF THE SYNCHRONIZATION OF THE UNITS OPTION...

Страница 15: ...45 42 43 PULIZIA SCAMBIATORE MANUTENZIONE STRAORDINARIA HEAT EXCHANGER CLEANING SERVICE Deve essere eseguita unicamente da personale tecnicamente qualificato Must be carried out only by technically q...

Страница 16: ...16 71 48 49 46 47 71 52 50 53 51 100mm VNRD100EC 115mm VNRD150EC...

Страница 17: ...17 56 54 55 Fig 57 441001K3RC 442001K3RC 443001K3RC I II COMANDO ESTERNO su richiesta ALTAMENTE RACCOMANDATO REMOTE CONTROLLER on request HIGHLY RECOMMENDED...

Страница 18: ...out dustbin indicates that this product must be collected separately from other waste at the end of its life The user must therefore dispose of the product in question at suitable electronic and elect...

Страница 19: ...o interno massimo Maximum internal leakage rate N A o2 Trafilamento esterno massimo Maximum external leakage rate 1 1 p1 Tasso di miscela interno Internal mixing rate N A p2 Tasso di miscela esterno E...

Страница 20: ...riportate su www ave it e sul catalogo commerciale vigente Notes For duration and warranty conditions regarding the single products please visit www ave it and see the current commercial catalogue Pr...

Отзывы: