Precautions 

 

If an AVE lighting fixture is used outdoors on a sunny day, ensure that it is in a shaded area and is 
well ventilated to help prevent overheating. 

Do not use AVE lighting fixtures in environments that are below 0°C OR 40°C. 

 

Suspension 

 

Suspending any object is potentially dangerous and should only be attempted by qualified 
individuals with thorough knowledge of the techniques and regulations for suspending objects. It is 
the responsibility of the installer to ensure all fixtures and effects are installed correctly. AVE 
strongly recommends inspecting installed systems every 6 months for signs of weakness or damage. 
If any damage or weakness is detected then remedial action should be taken immediately. The user 
is responsible for making sure the wall, ceiling, or structure is capable of supporting all objects 
suspended overhead. Any hardware used to suspend the fixture not associated with AVE is the 
responsibility of others. 

 

 

 

 

Содержание TRI FLAT

Страница 1: ...TRI FLAT User Manual...

Страница 2: ...T able of Contents Safety 2 Important Safety Instructions 3 Precautions 4 Suspension 4 Description 5 Features 5 Setup 6 Power Linking 6 Mounting 6 Operation 7 Menu Map 7 DMX Channel 8 Specifications 8...

Страница 3: ...d on this fixture 6 Clean only with a dry cloth 7 Do not install or operate near any heat sources such as radiators gas heaters stoves or other heating apparatus 8 Only use attachments and accessories...

Страница 4: ...dge of the techniques and regulations for suspending objects It is the responsibility of the installer to ensure all fixtures and effects are installed correctly AVE strongly recommends inspecting ins...

Страница 5: ...g the fixture from stands or lighting truss or mounting on the floor The Tri Flat is supplied out of the box with Auto programs including a sound active mode for plug and play operation with an amazin...

Страница 6: ...ut connector from the first fixture and connect to the power input of the second unit ensuring that the connector are firmly in place 3 Repeat step 2 for each additional fixture up to 7 fixtures Mount...

Страница 7: ...g Menu Map Main Level Program Level Description Addr 1 512 DMX Address Value Chnd 3Ch 3 Channel DMX Mode 7Ch 7 Channel DMX Mode SLnd nASt Master SL1 Slave Mode 1 SL2 Slave Mode2 SL3 Slave Mode3 SL4 Sl...

Страница 8: ...on 8 255 Stepping Colour 7 CH 0 7 No Function 8 199 Auto Colour slow fast 200 255 Sound Active Specifications Light Source 18 x 3W Tri Colour LED Diodes Diode Colour Red Green Blue Beam Angle 26 DMX C...