19
ENGLISH
Every configuration parameter featuring preset settings is identified on the
display by an index and a writing. To change parameter values use keys
▲
[key
1] and
▼
[key 2]; use key
►
[key 4] to move across parameters.
To go back to the initial page of the programming menu, press the ENTER key
[key 5] which will save changes.
If no key is pressed within 3 minutes, the chronothermostat will quit the
configuration program and will resume the operating mode being used
previously, without saving changed settings.
To cancel changed settings and to reset preset configuration parameter values,
keep keys
▲
[key 1] and
▼
[key 2] pressed simultaneously for about 4 seconds.
Index
Parameter
Writing
Values
Preset value
1
Type of connected card
COn
rEL / rAd / ---
none
2
Temperature scale
CELS o
FHAr
°C / °F
°C
3
Type of regulation
Std o
ProP
Std / ProP
Std
3A
Thermal differential
DIFF
HI / LO
LO
3A
Regulation band
BAnd
1 °C – 4 °C (step 0.1°C) 2 °C
3B
Regulation period
Per
5 / 10 / 20 minutes
10 minutes
4
Separate temperature probe
configuration
Sect
--- / FLO / In /Out
---
4A
Floor temperature limit
Tflo
15 °C – 45 °C
27.0 °C
5
Ambient temperature
correction
Corr
-4.0 °C to +4.0 °C
0.0 °C
6
Optimization
Opt
ON/OFF
OFF
6A
Max. optimization duration
(hours)
OPtH
1h – 5h
2h
7
Pump anti-seizure
Pu
ON/OFF
OFF
8
Low battery
bAtt
--- / On / OFF
OFF
9
Baud
baud
0/1
0
10
Software release
SOFt
xxx
xxx