14
Priming is ALWAYS necessary after the tool has been dismantled and prior to operating. It may also be necessary to restore the full
stroke after considerable use, when the stroke may be reduced and rivets are not fully placed by one operation of the trigger.
O I L D E T A I L S
The recommended oil for priming is Hyspin VG32 available in 0.5l (part number 07992-00025) or one gallon containers (part number
07992-00026). Please find specific table and safety data below.
P
R I M I N G
FIRST AID
SKIN: Wash thoroughly with soap and water as soon as
possible. Casual contact requires no immediate attention.
Short term contact requires no immediate attention.
INGESTION: Seek medical attention immediately.
DO NOT induce vomiting.
EYES: Irrigate immediately with water for several minutes.
Although NOT a primary irritant, minor irritation may occur
following contact.
FIRE
Suitable extinguishing media: CO2, dry powder, foam or
water fog. DO NOT use water jets.
PROPERTIES
RESULT
ISO oil type
HL
ISO viscosity grade
32
Kinematic viscosity
cS @ 40
°
C
32
@ 100
°
C
5.3
Relative density
at 20
°
C
0.875
Viscosity Index
95
Pour point
°
C
- 30
Open Flash point
°
C
232
Neutralisation value mg KOH/g
1.5
H Y S P I N V G 32 O I L
S A F E T Y D A T A
ENVIRONMENT
WASTE DISPOSAL: Through authorised contractor to a
licensed site. May be incinerated.
Used product may be sent for reclamation.
SPILLAGE: Prevent entry into drains, sewers and water courses.
Soak up with absorbent material.
HANDLING
Wear eye protection, impervious gloves (e.g. of PVC) and a
plastic apron. Use in well ventilated area.
STORAGE
No special precautions.
PROPERTIES
RESULT
Foaming tendency/stability
ml @ 24
°
C
Trace/Nil
ml @ 93.5
°
C
20/Nil
ml @ 24
°
C after test @ 93.5
°
C
Trace/Nil
Air release value minutes to
0.2% air content @ 50
°
C
4
Seal compatability index
10
Water separation time
in minutes to 40-40-0 @54
°
C
15
@83
°
C
15