WAE-PORT (Wideband Access Endpoint Port)
Issue 1 May 2002
8-1865
555-233-143
WAE-PORT (Wideband Access
Endpoint Port)
Wideband Switching supports end-to-end connectivity between customer
endpoints at data rates from 128 to 1536 kbps over T1 facilities and to 1984 kbps
over E1 facilities. S8700 Multi-Connect switching capabilities support wideband
calls comprised of multiple DS0s that are switched end-to-end as a single entity.
Wideband Switching extends the Administered Connections feature to include
non-signaling wideband access endpoints. Endpoint application equipment with
direct T1 or E1 interfaces may connect directly to the switch’s line-side facilities;
application equipment without T1 or E1 interfaces requires a terminal adapter
such as a DSU/CSU. The terminal adapter or endpoint application equipment is
connected to the TN464C Universal DS1 circuit pack.
These endpoints are administered as wideband access endpoints and have no
signaling interface to switch; they simply transmit and receive data. (Some
applications detect and respond to the presence or absence of data). Calls are
initiated from these endpoints using the Administered Connections feature.
Multiple access endpoints on one line-side UDS1 circuit pack facility are separate
and distinct within the facility. Endpoint application equipment must be
administered to send and receive the correct data rate over the correct DS0s.
Every Administered Connection originating from a wideband access endpoint
uses the entire bandwidth administered for the endpoint. An incoming call with a
different data rate than that administered for the endpoint cannot be routed to the
endpoint.
MO’s Name (in
Alarm Log)
Alarm
Level
Initial SAT Command to Run
1
1.
For additional repair information, see also
‘‘DS1-BD (DS1 Interface Circuit Pack)’’ on page 8-586
Full Name of MO
WAE-PORT (a)
MINOR
test access-endpoint extension l
Wideband Access
WAE-PORT
WARNING
test access-endpoint extension
Endpoint Port
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...