Maintenance-Object Repair Procedures
555-233-143
8-354
Issue 1 May 2002
BRI-SET, ASAI-ADJ, BRI-DAT
!
WARNING:
‘‘Isolating and Repairing Packet-Bus Faults’’
information for isolating and
resolving packet-bus faults is included in
Chapter 4, ‘‘Alarms, Errors, and
. The flowchart
, Troubleshooting Packet Bus
Problems along with the other information presented in the chapter, can help
resolve problems that involve more than a single station or circuit pack. See
also
‘‘Maintenance of the Packet Bus’’ on page 4-87
!
WARNING:
If a significant packet-bus failure occurs, errors and alarms may not be
logged as expected for BRI-PORT/ABRI-POR/ATT-PORT/ LGATE-PT/
ATTE-PT. Conditions under which this occurs are detailed in the
‘‘Maintenance of the Packet Bus’’
Chapter 4, ‘‘Alarms, Errors, and
.
MO’s Name As It
Appears in
Alarm Log
Alarm Level
Initial Command to Run
1
1.
UU is the universal cabinet number (1–64 for ATM PNC, 1–44 for CSS PNC). C is the carrier designation (A,
B, C, D, or E). SS is the number of the slot where the circuit pack resides (01–21). pp is the 2-digit port number
(01, 02,...).
Full Name of MO
BRI-SET
BRI-DAT
WARNING
2
2.
The alarm level for ASAI and Avaya adjuncts may be administered using the set options command. The alarm
level can be set independently for on- and off-board alarms to WARNING, MINOR, or MAJOR for every ASAI
and Avaya adjunct in the system.
test station extension l
test data-module extension
ISDN-BRI Set
ASAI-ADJ
MAJOR
test station extension
ASAI-Adjunct
ASAI-ADJ
MAJOR
test data-module extension
ASAI-Adjunct
ASAI-ADJ
WARNING
3
3.
Alarming for an ASAI and Avaya adjuncts is disabled if the adjunct asks the switch to suspend maintenance.
When this occurs, an error and a WARNING alarm are logged against the endpoint. Busying out and releasing
the ASAI station or ADJLK station will clear the alarm.
test data-module extension
ASAI-Adjunct
ATT-ADJ
MAJOR
test station extension
Avaya-Adjunct
ATT-ADJ
MAJOR
test station extension
Avaya-Adjunct
ATT-ADJ
WARNING
test station extension
Avaya-Adjunct
LGATE-AJ
MAJOR
test station extension
Ethernet ASAI-Adjunct
LGATE-AJ
MAJOR
test station extension
Ethernet ASAI-Adjunct
LGATE-AJ
WARNING
test station extension
Ethernet ASAI-Adjunct
ATTE-AJ
MAJOR
test station extension
Ethernet Avaya-Adjunct
ATTE-AJ
MAJOR
test station extension
Ethernet Avaya-Adjunct
ATTE-AJ
WARNING
test station extension
Ethernet Avaya-Adjunct
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...