Chapter 2        Preliminary Settings 

 

P114F Stackable Switch Installation Guide 

11 

 

Table 2 

Meaning of the P114F Stackable Switch front panel LEDs 

 

LED Indicator 

Function 

Status 

Meaning 

PWR Power 

OFF 
ON 
Blink 

Mains power not connected 
Mains power connected 
Working on back-up power supply 

NMA Agent 

OFF 
ON 

No agent in switch 
Switch contains an active agent 

RED NMA 

Reserved for future use 

Port 
LEDs 

1 to 8 

Each LED can display one of the following functions: Link, Collision, 
Transmit, Receive, Full Duplex, Flow Control or 100 M states, 
depending on what has been selected using the Select buttons. 

Function LED 

 

Port LED

 

 

 

LNK 

Link status 

OFF  
ON  
Blink once 
Blink 
twice 

Port Disabled  
Port is enabled and link is OK  
Link Test Fail.  
Partition. 

 COL 

Collision 

OFF 
ON 

No Collision 
Collision occurred on line 

 Tx 

Transmit 

to 

line 

OFF 
ON 

No activity 
Data transmitted 

 Rx 

Receive 
from line 

OFF 
ON 

No activity 
Data Received 

 FDX 

Half/Full 
duplex

*

 

OFF 
ON 

Port in Half Duplex mode  
Port in Full Duplex mode 

 FC 

Flow 
control

*

 

OFF 
ON 

Flow Control Inactive  
Flow Control Active 

 

100 M 

Port speed 

OFF 
ON 

(Not applicable) 
100 Mbps 

 

*

Half/Full duplex and Flow control are set via management. 

 

Содержание P114F

Страница 1: ...Avaya Installation Guide Avaya P114F STACKABLE SWITCH ...

Страница 2: ......

Страница 3: ...re fait UNIQUEMENT par un personnel de service qualifié Aucun élément ne peut être réparé par un particulier 2 NE PAS brancher allumer ou essayer de faire fonctionner une unité sur laquelle un doute existe quant à son bon fonctionnement 3 S assurer que les ouvertures d aération du châssis dans l appareil NE SONT PAS OBSTRUEES 4 Remplacer un fusible défaillant UNIQUEMENT par un modèle du même type ...

Страница 4: ...stbarkeit wie sie auf der Sicherheitsaufschrift markiert ist Die Aufschrift befindet sich neben der Stromzufuhr wo sich auch der Sicherungskasten befindet 5 Bedienen Sie das Gerät NICHT an einer Stelle an der die Umgebungstemperatur 50ºC übersteigt 6 Ziehen Sie das Netzkabel raus BEVOR Sie versuchen die Hauptsicherung zu kontrollieren oder auszutauschen ...

Страница 5: ...hs are possible in Full Duplex or to link to another P114F The P114F can operate standalone or as part of a stack A stack requires a P110 NMA to link the switches The units are physically linked using the P110 Exoplane which makes up a multi gigabit non blocking backplane Any combination of two three or four P110 switches can be stacked and up to 32 000 MAC addresses per stack are supported All po...

Страница 6: ......

Страница 7: ...f the P110 switch If the switch is to be rack mounted do not attach the feet Standalone Operation Plug n Play Getting the P110 switch working is quick and easy 1 Connect the power cable to the switch 2 Connect the cables to the front panel ports The switch is now fully operational By default all ports will operate in half duplex mode To ensure proper ventilation ensure that the P110 NMA slot is cl...

Страница 8: ...NMA installation Guide Before you download the new P110 NMA software please note that when upgrading from P110 NMA version 8 0 or below to 8 1 or higher all port configuration parameter settings will be lost The following parameters will be set back to the factory defaults In the P114T the Port Speed 10 100 Mbps parameter will be set to 100 Mbps The Port Mode Half Full Duplex parameter will be set...

Страница 9: ...ck are connected using P110 Exoplane cables with white connectors and marked C S B part number 108362203 Extra cables can be ordered from your local Avaya representative Figure 1 Rear view of a P110 switch stack showing how the switches are linked via the P110 Exoplane cables A P110 NMA resides in the uppermost switch 6 Two terminators are supplied with the P110 NMA Insert the two terminators into...

Страница 10: ...he ends of the front panel to reveal the fixing holes 2 Slot the switch into the rack Insert the switches into the rack so that the switches in a logical stack lie directly on top of each other Ensure that the P110 screw holes are aligned with the rack hole positions exactly as shown in Figure 3 Stacking them in this way will allow the switches to be easily connected using the P110 Exoplane cables...

Страница 11: ...Chapter 2 Preliminary Settings P114F Stackable Switch Installation Guide 9 Figure 2 P110 rack mounting arrangement ...

Страница 12: ...of LEDs The seven Function LEDs above the Select buttons show which function is currently displayed by the Port LEDs The Port LEDs can display either Link Collision Transmit Receive Full Duplex Flow Control or 100 M status If for example the Link LNK LED is lit then LEDs 1 to 8 will display the Link status of every port Press the left or right button to toggle the Port LED display between function...

Страница 13: ...mit Receive Full Duplex Flow Control or 100 M states depending on what has been selected using the Select buttons Function LED Port LED LNK Link status OFF ON Blink once Blink twice Port Disabled Port is enabled and link is OK Link Test Fail Partition COL Collision OFF ON No Collision Collision occurred on line Tx Transmit to line OFF ON No activity Data transmitted Rx Receive from line OFF ON No ...

Страница 14: ...Inc All rights reserved All trademarks identified by the or TM are registered trademarks or trademarks respectively of Avaya Inc All other trademarks are the property of their respective owners Document number 130006 Rev A ...

Отзывы: