Avaya Communication Manager controlled maintenance
System resets
Maintenance of the Avaya G350 Media Gateway
67
June 2004
Administering the MGC list
You can administer the gateway with a list of up to 4 alternate resources (TN799DP C-LAN circuit packs
or LSPs) that it can connect to in the event of link failure. The MGC list consists of the IP addresses to
contact and the order in which to re-establish the H.248 link.
To administer the MGC list:
1
At the gateway’s Command Line Interface (CLI) type
set mgc list <ipaddress>,
<ipaddress>,<ipaddress>,<ipaddress>
, where:
•
The first element is the IP address of the primary server (S8300) or the primary C-LAN
circuit pack (S8700).
•
The next three elements are the IP addresses of 1-3 LSPs (S8300s configured as such) or
of any other C-LAN circuit packs in the primary server’s configuration (S8700).
There are a total of four elements in this list.
2
Reset the gateway by typing
reset
.
Wait for the LEDs on the gateway and Media Modules to go out and the active status LEDs on the
gateway to go on, indicating that the reset is complete.
3
Check the MGC list administration by typing
show mgc list
.
Look in the CONFIGURED MGC HOST section of the output for the IP addresses of the
alternate resources.
Feature interactions and compatibility
H.248 Link Recovery can affect the performance of features or adjuncts within the configuration (
27, H.248 Link Recovery feature/adjunct interactions,
Table 27: H.248 Link Recovery feature/adjunct interactions 1 of 2
Feature or adjunct
Description
Feature Access Codes (FAC)
Feature Access Codes, whether dialed or administered
buttons, do not work.
Non-IP trunks/stations, including
such circuit-switched TDM resources
as DCP, analog, or ISDN-PRI
These resources are unavailable until the H.248 link is re-
established.
Terminals
Time-of-Day, busy lamp states, and call appearance status
on some phones might not instantaneously reflect the
correct information until the H.248 link is re-established.
Adjunct Switch Application Interface
(ASAI)
ASAI-based applications that utilize timing loops, time-
related methods, or events might not perform as intended.
In addition, applications that do not accommodate time-
outs or missing state transition(s) might behave
unpredictably.
1 of 2
Содержание Media Gateway G350
Страница 1: ...Maintenance of the Avaya G350 Media Gateway 555 245 105 Issue 3 June 2004 ...
Страница 16: ...About this book Sending us comments 16 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 48: ...G350 component maintenance IP telephones 48 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 284: ...Monitoring Extended keepalive 284 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 306: ...G350 traps G350 traps and resolutions 306 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 326: ...Media Server alarms S8300 alarms UPS 326 Maintenance of the Avaya G350 Media Gateway June 2004 ...