G350 component maintenance
Setting G350 synchronization
Maintenance of the Avaya G350 Media Gateway
43
June 2004
To activate the secondary sync source:
To activate the local sync source:
To reactivate the primary sync source:
If the T1 physical connection is removed, then the secondary becomes active and the primary reports a
failure.
Table 13: G350-001# set sync source secondary
G350-001# show sync timing
SOURCE
MM
STATUS
FAILURE
Primary
V4
Locked Out
None
Secondary
V3
Active
None
Local
V0
Standby
None
Note: The system uses one clock at a time only: therefore only the secondary is active and the
primary is locked out.
Table 14: G350-001# set sync source local
G350-001# show sync timing
SOURCE
MM
STATUS
FAILURE
Primary
V4
Locked Out
None
Secondary
V3
Locked Out
None
Local
V0
Active
None
Table 15: G350-001# set sync source primary
G350-001# show sync timing
SOURCE
MM
STATUS
FAILURE
Primary
V4
Active
None
Secondary
V3
Standby
None
Local
V0
Standby
None
Note that secondary and local are standby because they are provisioned as fail overs.
Table 16: G350-001# show sync timing
SOURCE
MM
STATUS
FAILURE
Primary
V4
Standby
Out of Lock
Secondary
V3
Active
None
Local
V0
Standby
None
Note that primary and local are standby because they are provisioned as fail overs.
Содержание Media Gateway G350
Страница 1: ...Maintenance of the Avaya G350 Media Gateway 555 245 105 Issue 3 June 2004 ...
Страница 16: ...About this book Sending us comments 16 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 48: ...G350 component maintenance IP telephones 48 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 284: ...Monitoring Extended keepalive 284 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 306: ...G350 traps G350 traps and resolutions 306 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 326: ...Media Server alarms S8300 alarms UPS 326 Maintenance of the Avaya G350 Media Gateway June 2004 ...