G350 component maintenance
Setting G350 synchronization
42
Maintenance of the Avaya G350 Media Gateway
June 2004
NOTE:
The following command is sent from the SAT CLI, and not from the G350 CLI.
To test for slippage, from the SAT, use the command:
test mo logical 4255 physical 1v4 test 144
The results from the above command are shown in
If a secondary sync source is similarly provisioned:
Table 10: G350-001# set sync source primary
G350-001# show sync timing
SOURCE
MM
STATUS
FAILURE
Primary
V4
Active
None
Secondary
Not Configured
Local
V0
Standby
None
Comment: The ACT LED does not change its behavior.
Table 11: TEST RESULTS
Port
Maintenance
Name
Alt. Name
Test No.
Result
Error Code
001V4 MG-DS1
144
PASS
Command successfully completed
Table 12: G350-001# set sync interface secondary v3
G350-001# show sync timing
SOURCE
MM
STATUS
FAILURE
Primary
V4
Active
None
Secondary
V3
Standby
None
Local
V0
Standby
None
Содержание Media Gateway G350
Страница 1: ...Maintenance of the Avaya G350 Media Gateway 555 245 105 Issue 3 June 2004 ...
Страница 16: ...About this book Sending us comments 16 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 48: ...G350 component maintenance IP telephones 48 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 284: ...Monitoring Extended keepalive 284 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 306: ...G350 traps G350 traps and resolutions 306 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 326: ...Media Server alarms S8300 alarms UPS 326 Maintenance of the Avaya G350 Media Gateway June 2004 ...