reset translation-id
Issue 4 May 2002
8-277
555-233-123
reset translation-id
This command resets the translation-ID on the translation card(s) to match the
processor(s), saves translations to the memory card, and restores use of the add,
change, remove, and duplicate commands.
NOTE:
This command can be executed only by Avaya Services.
Error message
In duplicated systems, the message,
Cannot reset translation-ID without standby SPE being
accessible
means that both processors must be sane and operational.
■
A standby SPE that has been busied out must be released (release
standby-spe).
■
Check that the SPE-select switches on the DUPINT circuit pack are in the
AUTO position.
reset val
This command performs the functions of the reset board command but overrides
querying the board to determine if an announcement autosave is in process. This
allows resetting the circuit pack if it is in the insane state.
Screen 8-25.
Reset VAL report
Action/Object
Qualifier
Qualifier Description
Logins
Defaults
Feature
Interactions
reset
translation-id
Example:
reset translation-id
Avaya Services only
See
reset val 1C07
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01C07 VAL-BD 53 PASS
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...