How to use the Maintenance book
Issue 4 May 2002
1-5
555-233-123
14. Look in
for Test #35, then “61472” in the Error Code column, and
“FAIL” in the Test Result column. See the Description/Recommendation
information.
15. Perform both steps in the Description/Recommendation column.
16. Test the port (test port 01C1008 long and press
Enter
) after all of the
recommendations are exhausted.
17. If all tests pass, wait approximately 3-5 minutes for the Alarm and Error
logs to clear.
18. Type display alarms and press
Enter
twice.
19. Check that the DID-TRK alarm does not appear in the log.
Field descriptions
Table 1-3. TEST #35 Port Diagnostic Test
Error
Code
Test
Result
Description/Recommendation
61472
FAIL
Battery feed test failed. A problem with the incoming CO line was detected.
1. Check the incoming CO line for proper operation. If warranted,
refer the problem to the CO.
2. If the CO line checks out Ok, the failure must be on the DID
port. Replace the circuit pack.
Error type
Enter error type, or blank
Error List
active-alarms, errors, or cleared-errors
Interval
h(our), d(ay), w(eek), m(onth), a(ll)
From:/To:
Specify time interval by date and time
Cabinet
Enter cabinet number (1 - 44)
Port Network
Enter port network number (1 - 44)
Board Number
Enter 5-character board number in UUCSS format:
cabinet (1-44), carrier (A-E), slot (0-20)
Port
Enter 7-character port address in UUCSSss format:
cabinet (1-44), carrier (A-E), slot (0-20), circuit (01-31)
Category
Enter category name (choose 1 from the list below:
adm-conn
announce
bri/asai
cdr
data-mod
detector
dup-spe
environ
exp-intf
ext-dev
generatr
inads-link
infc
maint
mass-st
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...