5. The following two patterns may occur when the circuit pack is either in
Active or Standby mode. The best approach to determine the mode of the
circuit pack is to use the status system system technician command.
■
Maintenance running on the Standby circuit pack is indicated by the
following pattern (yellow and green LEDs flashing): LED on 0.1
seconds, off for 0.2 seconds, on for 0.1 seconds, off for 0.4 seconds,
on for 0.4 seconds, off for 0.4 seconds.
■
Green flashing and yellow flashing in a pattern different than the
previously mentioned pattern indicates that maintenance is running
on the Active circuit pack.
Error Log Entries and Test to Clear Values
Table 10-588.
Synchronization Error Log Entries
Error Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test synchronization
1 (a)
Any
None
WARNING/
MINOR(j)
2
2
This error type initially raises a Warning alarm. If this error type persists and alarms are not
downgraded on this MO due to the value of set options, then, after a period of time, a Minor or Major
alarm is raised.
OFF
None
18 (b)
0
disable sync
WARNING
OFF
enable sync
257 (c)
Any
None
WARNING/
MINOR(j)
OFF
None
513 (d)
Any
None
WARNING/
MAJOR(j)
OFF
None
769 (e)
None
MAJOR/
WARNING
3
3
Major alarms on this MO may be downgraded to Warning alarms based on the value used in the set
options command.
OFF
None
1793 (f)
4
4
It may take up to one hour for these SYNC alarms to clear due to “leaky bucket” strategy.
0-50
None
MAJOR/
WARNING
OFF
enable sync
2049 (g) (i)
0
None
WARNING
OFF
None
2305 (h) (i)
0
None
WARNING
OFF
None
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...