Routine Maintenance Procedures
555-233-123
5-90
Issue 4 May 2002
Q.SAAL (Data Link) Layer
Are ATM signaling messages reaching A500 Call Control?
1. Enter show signaling stats port qsaal on the A500 console.
shows the screen output.
Screen 5-28.
A500: show signaling stats a1.2 qsaal screen
NOTE:
If there is no connection between the TN230X and the A500 at the Q.SAAL
protocol layer, then no report is displayed.
— If
Port A1.2
(or the port of interest) is
not configured for
UNI signaling
, then the port was administered for no UNI
signaling (admin link command). Use the show signaling
summary command to verify that
Signaling
is
UNI3.1
.
— The
Supported only for UNI 3.0
line for the
SDP PDUs:
field means that the port was administered for UNI3.0 signaling
(admin link command). Use the show signaling summary
command to verify that
Signaling
is
UNI3.1
.
— The
POLL PDUs
and
STAT PDUs
counters should be increasing if
the TN230X is actively sending and receiving Q.SAAL Protocol Data
Units with the A500. This occurs even if the TN230X did not achieve
board insertion.
A500: show signaling stats a1.2 qsaal
------------------------Q.SAAL Statistics------------------------
Port A1.2:
----------
Type: UNI3.1
VPI: 0x00, VCI: 0x05
Tx Rx
-------- --------
BGN PDUs: 0 1
BGAK PDUs: 1 0
END PDUs: 0 0
ENDAK PDUs: 0 0
RS PDUs: 0 0
RSAK PDUs: 0 0
BGREJ PDUs: 0 0
SD PDUs: 81 78
SDP PDUs: Supported only for UNI 3.0
ER PDUs: 0 0
POLL PDUs: 6259 5720
STAT PDUs: 5720 6259
USTAT PDUs: 0 0
ERAK PDUs: 0 0
Discarded PDUs: 0 0
Errored PDUs: 0 0
Buffers in use: 0 0
High buffer mark: 3 0
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...