Routine Maintenance Procedures
555-233-123
5-86
Issue 4 May 2002
Physical Layer
Is there an optical signal between the TN230X and the A500?
1. Does the TN230X’s yellow LED flash 100ms on/100ms off, indicating a loss
of signal on the fiber? The TN230X detects continuity problems with either
the Transmit (bottom) or the Receive (top) fibers.
2. Is the A500 port’s CD LED off, indicating a loss of signal on the fiber? The
A500 detects continuity problems only with the Receive (right-hand) fiber;
the state of the Transmit (left-hand) fiber is not detected.
3. Type show signaling summary on the A500 console.
shows
the output.
Screen 5-25.
A500: show signaling summary screen
Ensure that the fields have the values indicated below.
4. Enter show system interfaces on the A500 console.
shows an example of the screen output.
SAP
State
Up
If it is
PHY_DOWN
or
DOWN
, then there is probably a loss of signal on
the port in question. This command detects a continuity problem only
with the Receive (right-hand) fiber; it does not detect the state of the
Transmit (left-hand) fiber.
State
The value of may be
UP
or
DOWN
, depending on the administration of
the port.
It may be necessary to re-administer the A500 port
boards. Refer to the Cajun A500 Quick Reference for further
information.
A500:show signaling summary
Port loc VCI SAP IntType Signaling ILMI SAP State State
------ ------- --- ------- ----------- ---- ------------ -----
A1.1 1 1 Network UNI3.1 No UP UP
A1.2 2 2 Network UNI3.1 No UP UP
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...