MAINT (EPN Maintenance Circuit Pack)
Issue 4 May 2002
10-1021
555-233-123
Notes:
a. A value of 0 indicates the Expansion Link in the A carrier was active when
this error occurred. A value of 1 indicates the Expansion Link in the B
carrier was active when this error occurred. To clear this problem, make
sure the Active Expansion Link is the same as that indicated by the Aux
Value.
b. Multiple values can appear in the Aux Data field. There are other errors in
the log if there is a real problem. Use these other errors to troubleshoot the
problem.
c. The serial link between the Expansion Link in the A carrier and the EPN
Maintenance circuit pack is defective.
d. The serial link between the Expansion Link in the B carrier and the EPN
Maintenance circuit pack is defective.
3073
(a)
0
1
Network Control Circuit Pack
DPR Test (#104)
MAJOR/
WARNING
2
OFF
test maintenance l
3329
(c)
Any
Serial Link Test (#337)
MINOR/
WARNING
OFF
test maintenance sh r 3
3585
(d)
Any
Serial Link Test (#337)
MINOR/
WARNING
OFF
test maintenance sh r 3
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2
Major and Minor alarms on this MO may be downgraded to Warning alarms based on the value used
in the set options command.
Table 10-368.
EPN Maintenance Circuit Pack Error Log Entries — Continued
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...