Maintenance Object Repair Procedures
555-233-123
10-858
Issue 4 May 2002
Monitor download progress
1. Type status firmware download and press
Enter
.
The Status Firmware Download screen (
) displays.
Screen 10-12.
Status Firmware Download screen
Aborting a firmware download
If you need to abort a scheduled (pending) firmware download:
1. Type disable firmware download and press
Enter
.
This command
■
Continues to download the firmware image file to circuit pack in
progress.
■
Aborts the remainder of the download schedule.
■
Clears the contents of the Status Firmware Download screen
(
).
Disable filesystem
Performing the following steps on the TN799DP (C-LAN) or TN2501AP (VAL)
circuit packs, removes only the ftplogin and the ftppassword. The allocated
memory for the file system remains reserved for the session.
To free up resources on the source circuit pack, you must delete the new firmware
image files and disable the filesystem.
1. Type remove file board <UUCSS> <filename> and press
Enter
to remove
image files from the source board.
status firmware download Page 1 of 1
STATUS FIRMWARE DOWNLOAD
Source Board Location: 01C02
Firmware Image File Name: usd1v22r1
Target Board Code: TN464 Suffix: GP Firmware Vintage: 1
Schedule Download? _ Remove Image File After Successful Download? _
Start Date/Time: 01/12/2001 13:30 Stop Date/Time: 01/14/2001 16:30
Target Target Target Target Target
Location St Location St Location St Location St Location St
1.01C04 C 11. _____ _ 21. _____ _ 31. _____ _ 41 _____ _
2.01C06 C 12. _____ _ 22. _____ _ 32. _____ _ 42 _____ _
3.01C08 P 13. _____ _ 23. _____ _ 33. _____ _ 43. _____ _
4. _____ _ 14. _____ _ 24. _____ _ 34. _____ _ 44. _____ _
5. _____ _ 15. _____ _ 25. _____ _ 35. _____ _ 45. _____ _
6. _____ _ 16. _____ _ 26. _____ _ 36. _____ _ 46. _____ _
7. _____ _ 17. _____ _ 27. _____ _ 37. _____ _ 47. _____ _
8. _____ _ 18. _____ _ 28. _____ _ 38. _____ _ 48. _____ _
9. _____ _ 19. _____ _ 29. _____ _ 39. _____ _ 49. _____ _
10. _____ _ 20. _____ _ 30. _____ _ 40. _____ _ 50. _____ _
Status: Pending(P) Completed(C) Failed(F) Aborted (A)
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...