Procedure for SPE-Down Mode
Issue 4 May 2002
4-9
555-233-123
Display for SPE-Down in a High or Critical
Reliability System:
**************SPE DOWN MODE************
You can display alarms [a|b] and reset system(4) [a|b].
SPE_DOWN->
shows only one SPE-Down alarm in a high or critical reliability system
after entering the display b command:
Screen 4-2.
Display Alarms (one SPE-Down)
NOTE:
A standard reliability system tries to restart itself every 20 minutes. A high or
critical system tries to restart itself every 10 minutes.
The first step is to determine the location of the problem. It is possible for two or
more circuit packs to have failed. It is also possible for a fatal problem with one
circuit pack to affect another circuit pack. This is especially true for the Processor
and Memory circuit packs, where a failure in one affects the other. All three of the
following methods should be employed to determine where the fatal fault lies.
1. Use display alarms command.
Issuing the display alarms [a | b] command at the administration terminal
shows where maintenance thinks the problem lies. The alarms are a good
indication of why the system went down. They should be used with the
following two methods.
2. Observe red LEDs.
Observe the red LEDs on the circuit pack to determine where software or
processor firmware (LMM) had a problem.
3. Use the reset command.
In 286 system, issuing the reset command (Standard Reliability system) or
the reset [a | b] command (High or Critical Reliability system) causes the
system to attempt a reset system 4. Observe all the diagnostics on the
screen, and note if the LMM has a problem with any of the diagnostics, as
this information should give a good indication of where the problem lies.
DISPLAY ALARMS B:
Physical Logical On Alternate Alarm Date Date
Name Name Board? Name Type Alarmed Resolved
------ PROC_BD y ----- MAJOR ------ ------
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...