 Installing and operating the Rackmount Charger

202

Avaya DECT R4 - Installation and Maintenance Guide

06/2009

Installation alternatives

The CR3 as delivered can be installed as a single unit. When installed as a single unit, the 
power cord with the C14 connector may be used with a suitable extension cord to be 
plugged into a wall outlet. Up to four single units may be connected to one single LAN 
outlet.

If more than one CR3 is used in a serial configuration a fixed installation must be made. 
For safety reasons it is not allowed to supply more than one unit by the power cord with the 
C14 connector. When units are supplied in series, the installation must be made by an 
authorized electrician and the C14 connectors must be removed. Maximum five units may 
be connected in serial power supply, but LAN serial connection is limited to four units.

In Sweden, Norway and Finland a connection to protective earth (safety grounding) must be 
provided.

Safety

The Rack Charger CR3 is connected to 100-240VAC/0.7A 50/60 Hz. For safety reasons:

the safety covers on top of the supply voltage terminal blocks must be mounted to prevent 
hazardous situations, like electric shock.

when servicing the units the mains power supply cable must be disconnected.

Note the following:

for PERMANENTLY CONNECTED EQUIPMENT, a readily accessible disconnect device 
shall be incorporated in the building installation wiring. The disconnect device shall 
disconnect both poles.

for PLUGGABLE EQUIPMENT, the socket-outlet shall be installed near the equipment and 
shall be easily accessible.

In Sweden, Norway and Finland the unit must be connected to a wall outlet with protective earth 
(safety grounding). For other countries it is recommended to use a protective earth connection.

Suomi: Laite on liitettävä suojamaadoituskoskettimilla varustettuun pistorasiaan.

Norge: Apparatet må tillkoples jordet stikkontakt.

Sverige: Apparaten skall anslutas till jordat uttag.