![Avaya callpilot 1002rp Скачать руководство пользователя страница 83](http://html1.mh-extra.com/html/avaya/callpilot-1002rp/callpilot-1002rp_maintenance-and-diagnostics_3028038083.webp)
Table 16: Drive pair settings
LED No
ID
Channel-1
LED No
ID
Channel-2
0
0
ONLIN A01-01
3
0
ONLIN A01-02
1
1
ONLIN A02-01
4
1
ONLIN A02-02
2
2
ONLIN A03-01
5
2
ONLIN A03-02
Note:
If your settings do not match those in the table, stop and contact your next level of
support for assistance before continuing.
4. Check that all drives are marked in green and Online.
Note:
If they are not all online, stop and contact your next level of support for assistance
before continuing.
5. Check the RAID drive consistency:
a. Select Check Consistency.
Result: The Logical Drives Configured dialog box appears.
b. Use the arrow key to highlight the first drive to be checked.
c. Press the space key to select the drive.
d. Press F10 to check consistency.
Result: The Do you wish to continue? dialog box appears.
e. Click Ok.
Result: The consistency check begins and a status dialog box appears.
f. Repeat steps c to e for each drive until all three drives have been checked
for consistency. This may take up to 2 hours to complete. If any data
consistency errors are detected, they are corrected automatically.
6. Perform a full-system backup of the CallPilot server (either to tape or file server).
7. Review the backup logs to verify success.
8. Perform a controlled shutdown of the CallPilot software:
a. Click Ctrl+Alt+Delete and select Shutdown from the Windows Security
window.
Result: The Shutdown Computer dialog box appears.
b. Select Shutdown.
Result: The CallPilot server turns off.
9. Remove power from the system by disconnecting the AC or DC mains.
Replacing the SCA SCSI drive cage and fused power cable
Avaya CallPilot® 1002rp Server Maintenance and Diagnostics
December 2010 83
Содержание callpilot 1002rp
Страница 1: ...Avaya CallPilot 1002rp Server Maintenance and Diagnostics 5 0 NN44200 701 01 05 December 2010 ...
Страница 4: ...4 Avaya CallPilot 1002rp Server Maintenance and Diagnostics December 2010 ...
Страница 10: ...10 Avaya CallPilot 1002rp Server Maintenance and Diagnostics December 2010 ...
Страница 18: ...About this guide 18 Avaya CallPilot 1002rp Server Maintenance and Diagnostics December 2010 ...
Страница 96: ...Replacing basic chassis components 96 Avaya CallPilot 1002rp Server Maintenance and Diagnostics December 2010 ...
Страница 118: ...RAID operations 118 Avaya CallPilot 1002rp Server Maintenance and Diagnostics December 2010 ...
Страница 130: ...Replacing or adding voice processing boards 130 Avaya CallPilot 1002rp Server Maintenance and Diagnostics December 2010 ...
Страница 146: ...Maintaining the Pentium III SBC card 146 Avaya CallPilot 1002rp Server Maintenance and Diagnostics December 2010 ...