Avaya 4900 Series Скачать руководство пользователя страница 6

Table 5: PoE+ specifications

Model

Number of
Power Supplies

Power supply

Power over Ethernet (PoE+)

power output

Rated

Line voltage

Max
Power
per Port
(Watts)

Max power
output

Sum of all Ports
(Watts)

ERS 4950GTS-
PWR+

1

1025 W

200–240 VAC

30 W

720 W

24 ports
at 30 W

2

1025 W

200–240 VAC

30 W

1440 W 48 ports

at 30 W

1

1025 W

100–110 VAC

30 W

720 W

24 ports
at 30 W

2

1025 W

100–110 VAC

30 W

1440 W 48 ports

at 30 W

ERS 4926GTS-
PWR+

1

1025 W

200–240 VAC

30 W

720 W

24 ports
at 30 W

2

1025 W

200–240 VAC

30 W

720 W

24 ports
at 30 W

1

1025 W

100–110 VAC

30 W

720 W

24 ports
at 30 W

2

1025 W

100–110 VAC

30 W

720 W

24 ports
at 30 W

AC power cord specifications

The following section outlines the AC power cord specifications for various countries. Ensure that

you use the correct cord for your location.

Table 6: International power cord specifications

Country / Plug Specification

Specifications

Typical Plug

Continental Europe:

• CEE7 standard VII male plug

• Harmonized cord (HAR marking on the

outside of the cord jacket to comply with
the CENELEC Harmonized Document
HD-21)

• 220 or 230 VAC

• 50 Hz

• Single Phase

Table continues…

June 2016

Installation Job Aid for Avaya Ethernet Routing Switch 4900 Series (NN47212-302,

ver 02.01)

6

Содержание 4900 Series

Страница 1: ... reseller and you need assistance contact the technical support staff for that distributor or reseller Notices Notice paragraphs alert you about issues that require your attention The following paragraphs describe the types of notices used in this guide Note Notes provide tips and useful information regarding the installation and operation of Avaya products Electrostatic alert ESD ESD notices prov...

Страница 2: ...nly Read and follow all warning notices and instructions marked on the product or included in the documentation Voltage This equipment relies on the building s installation for overcurrent protection Ensure that a fuse or circuit breaker no larger than 120 VAC 20 A or 240 VAC 16 A is used on the phase conductors Caution This device is a Class A product In a domestic environment this device can cau...

Страница 3: ...r the switches in this series Ensure that the area where you install the switch and where it operates meets these requirements Warning To avoid bodily injury from hazardous electrical shock and current never remove the top of the device No user serviceable components are inside Table 1 Physical specifications Height 4 4 cm 1RU Width 17 32 inch 440 mm or 44 cm 19 inch rack mountable Depth 18 89 inc...

Страница 4: ... ventilation Cables should be dressed to prevent blocking air flow Power specifications This section provides the following power specifications for the switch AC power specifications on page 4 Typical power consumption on page 5 PoE specifications on page 6 The following table describes the AC power specifications Table 3 AC power specifications Model Number of Power supplies Power supply Input p...

Страница 5: ... 11 7 55 413 56 2 1025 W 100 110 VAC 839 64 7 73 424 24 The following table provides typical power consumption Table 4 Typical power consumption Model Idle Power consumption Watts Typical Power consumption Watts Devices connected to all ports typical traffic without SFPs Devices connected to all ports typical traffic 6 W average per PoE device With Avaya Energy Saver enabled PoE Saver disabled on ...

Страница 6: ...W 24 ports at 30 W 1 1025 W 100 110 VAC 30 W 720 W 24 ports at 30 W 2 1025 W 100 110 VAC 30 W 720 W 24 ports at 30 W AC power cord specifications The following section outlines the AC power cord specifications for various countries Ensure that you use the correct cord for your location Table 6 International power cord specifications Country Plug Specification Specifications Typical Plug Continenta...

Страница 7: ...this section apply to all switches in Avaya Ethernet Routing Switch 4900 Series About this task Install the switch in an equipment rack Before you begin Tool requirements Phillips screwdriver to attach brackets to the switch and the switch to the rack Rack requirements Space of 2 8 inches 7 1 cm for each switch is available in an E1A or 1EC standard 19 inch 48 2 cm equipment rack and T1A 23 inch 5...

Страница 8: ...the appropriate bolts to secure the switch to your specific rack before you begin Procedure 1 Ensure power is disconnected from the switch 2 Attach a bracket to each side of the switch with the included screws You have different options for front and rear mounting positions Attach the brackets in the best position for your specific equipment rack Figure 1 Front mounted rack bracket installation Ju...

Страница 9: ... post equipment rack installations an optional four post rack mounting kit sold separately is available that includes adjustable rear brackets For more information see Installing Avaya Ethernet Routing Switch 4900 Series NN47212 301 June 2016 Installation Job Aid for Avaya Ethernet Routing Switch 4900 Series NN47212 302 ver 02 01 9 ...

Страница 10: ...Figure 3 Front mounted rack installation June 2016 Installation Job Aid for Avaya Ethernet Routing Switch 4900 Series NN47212 302 ver 02 01 10 ...

Страница 11: ...optional four post rack mounting kit sold separately is available that includes adjustable rear brackets For more information see Installing Avaya Ethernet Routing Switch 4900 Series NN47212 301 June 2016 Installation Job Aid for Avaya Ethernet Routing Switch 4900 Series NN47212 302 ver 02 01 11 ...

Страница 12: ...Figure 5 Rack mount attachment screws June 2016 Installation Job Aid for Avaya Ethernet Routing Switch 4900 Series NN47212 302 ver 02 01 12 ...

Страница 13: ...tallation by connecting power and network connections to the switch Connecting AC power About this task The Ethernet Routing Switch 4900 Series does not have a power switch When you connect the AC power cord to a suitable AC power outlet the switch powers up immediately Before you begin Ensure to use the correct power cord for the switch and power supply Procedure 1 Connect the AC power cord to th...

Отзывы: