Avantco SCL1 Скачать руководство пользователя страница 6

- 6 -

User Manual

Regular Maintenance

WARNING: DISCONNECT POWER CORD BEFORE 

CLEANING ANY PARTS OF THE UNIT.

Cleaning The Condenser Coil

• For efficient operation, it is important that the condenser surface be kept free of dust, dirt, and lint.
• We recommend cleaning the condenser coil and fins at least once per month.
•  Clean with a commercial condenser coil cleaner, available from any kitchen equipment retailer. 

Brush the condenser fins from top to bottom, not side to side.

• After cleaning, straighten any bent condenser fins with a fin comb.

Cleaning The Fan Blades and Motor

If necessary, clean the fan blades and motor with a soft cloth. If it is necessary to wash the fan 
blades, cover the fan motor to prevent moisture damage.

Cleaning The Interior of Unit

•  When cleaning the cabinet interior, use a solvent of warm water and mild soap.
•   Do not use steel wool, caustic soap, abrasive cleaners, or bleach that may damage the stainless 

steel surface.

•   Wash door gaskets on a regular basis, preferably weekly. Simply remove door gasket from the 

frame of the door, soak in warm water and soap for thirty (30) minutes, dry with soft cloth, and 
replace.

•  Check door gaskets for proper seal after they are replaced.
•   Periodically remove the shelves and pilasters from the unit and clean them with mild soap and 

warm water. To remove the pilasters, first remove the shelves and shelf brackets. Then, simply lift 
the pilaster up and out.

Содержание SCL1

Страница 1: ...maintenance 01 2016 Refrigerated Pizza Prep Units PICL1 PICL2 PICL3 Refrigerated Sandwich Prep Units SCL1 SCL2 SCL236 SCL260 SCL3 SCLM1 SCLM2 SCLM236 SCLM260 SCLM3 Undercounter Refrigerators and Freez...

Страница 2: ...tdoor use may cause decreased efficiency and damage to the unit Avoid installation in a high humidity and or dusty area Humidity could cause unit to rust and decrease efficiency of the unit Dust colle...

Страница 3: ...o adjust the temperature you want it to run at Press SET again to save your settings If the unit consistently runs 5 degrees higher than your set temperature service may be needed Note All other contr...

Страница 4: ...t button snowflake symbol and down arrow for approximately 3 seconds Repeat to stop the defrost cycle Defrost Systems Refrigerator coils are kept below the freezing point 32 F During compressor down t...

Страница 5: ...o the compressor Unplug Cord To minimize shock and fire hazards please do not plug or unplug the cord with wet hands During maintenance and cleaning please unplug the unit Proper Grounding Required To...

Страница 6: ...and motor with a soft cloth If it is necessary to wash the fan blades cover the fan motor to prevent moisture damage Cleaning The Interior of Unit When cleaning the cabinet interior use a solvent of...

Страница 7: ...sket and wash with soap and water Check condition of gasket and replace if necessary Dirty condenser coil Clean the condenser coil Evaporator coil iced over Unplug unit and allow coil to defrost Make...

Страница 8: ...plate located on the front of the unit Next call 1 800 678 5517 Be sure to have the model number cabinet serial number and service plate number available when contacting service technicians This warra...

Отзывы: