Avantco 178DLC36HCB Скачать руководство пользователя страница 2

- 2 -

User Manual

Warning

DANGER – RISK OF FIRE OR EXPLOSION. FLAMMABLE REFRIGERANT USED. TO BE REPAIRED ONLY BY 

TRAINED SERVICE PERSONNEL. DO NOT PUNCTURE REFRIGERANT TUBING. 

PELIGRO - RIESGO DE INCENDIO O EXPLOSION. REFRIGERANTE INFLAMABLE UTILIZADO. PARA 

SER REPARADO SOLAMENTE POR PERSONAL DE SERVICIO CALIFICADO. NO PINCHAR LA TUBERÍA 

REFRIGERANTE.

DANGER – RISQUE DE FEU OU D’EXPLOSION. LE FRIGORIGÈNE EST INFLAMMABLE. CONFIER LES 

RÉPARATIONS À UN TECHNICIEN SPÉCIALISÉ. NE PAS PERFORER LA TUBULURE CONTENANT LE 

FRIGORIGENE. 

CAUTION – RISK OF FIRE OR EXPLOSION. FLAMMABLE REFRIGERANT USED. CONSULT REPAIR 

MANUAL/OWNER’S GUIDE BEFORE ATTEMPTING TO SERVICE THIS PRODUCT. ALL SAFETY 

PRECAUTIONS MUST BE FOLLOWED. 

ATENCION - RIESGO DE INCENDIO O EXPLOSIÓN. REFRIGERANTE INFLAMABLE UTILIZADO. CONSULTE 

EL MANUAL DE REPARACIÓN / GUÍA DEL PROPIETARIO ANTES DE INTENTAR DAR SERVICIO A ESTE 

PRODUCTO. DEBEN CUMPLIR CON TODAS LAS PRECAUCIONES DE SEGURIDAD.

ATTENTION – RISQUE DE FEU OU D’EXPLOSION. LE FRIGORIGÈNE EST INFLAMMABLE. CONSULTER LE 

MANUEL DU PROPRIÉTAIRE/GUIDE DE RÉPARATION AVANT DE TENTER UNE RÉPARATION. TOUTES LE 

MESURES DE SÉCURITÉ DOIVENT ÊTRE RESPECTÉES. 

CAUTION – RISK OF FIRE OR EXPLOSION DUE TO PUNCTURE OF REFRIGERANT TUBING; FOLLOW 

HANDLING INSTRUCTIONS CAREFULLY. FLAMMABLE REFRIGERANT USED. 

ATENCION - RIESGO DE INCENDIO O EXPLOSIÓN DEBIDO A LA PERFORACION DE LA TUBERÍA 

REFRIGERANTE; SIGA LAS INSTRUCCIONES DE MANIPULACIÓN CON CUIDADO. REFRIGERANTE 

INFLAMABLE UTILIZADO.

ATTENTION – RISQUE DE FEU OU D’EXPLOSION SI LA TUBULURE CONTENTANT LE FRIGORIGÈNE 

EST PERFORÉE; SUIVRE LES INSTRUCTIONS DE MANUTENTION AVEC SOIN. LE FRIGORIGÈNE EST 

INFLAMMABLE. 

CAUTION – RISK OF FIRE OR EXPLOSION DUE TO FLAMMABLE REFRIGERANT USED. FOLLOW 

HANDLING INSTRUCTIONS CAREFULLY IN COMPLIANCE WITH LOCAL GOVERNMENT REGULATIONS. 

ATENCIÓN – RIESGO DE INCENDIO O EXPLOSIÓN DEBIDO A REFRIGERANTE INFLAMABLE UTILIZADO. 

SIGA LAS INSTRUCCIONES DE MANIPULACIÓN CON CUIDADO CONFORME A LAS REGLAS DE LA 

MUNICIPALIDAD.

ATTENTION – RISQUE DE FEU OU D’EXPLOSION SI LE FRIGORIGÈNE EST INFLAMMABLE. SUIVRE 

LES INSTRUCTIONS DE MANUTENTION AVEC SOIN CONFORMÉMENT AUX RÈGLEMENTATION 

GOUVERNEMENTALE LOCAUX. 

Содержание 178DLC36HCB

Страница 1: ...igerated Deli Cases 178DLC36HCB 178DLC36HCS 178DLC36HCW 178DLC47HCB 178DLC47HCS 178DLC47HCW 178DLC64HCB 178DLC64HCS 178DLC64HCW 178DLC82HCB 178DLC82HCS 178DLC82HCW Please read the manual thoroughly prior to equipment set up operation and maintenance 08 2018 ...

Страница 2: ...RIGORIGÈNE EST INFLAMMABLE CONSULTER LE MANUEL DU PROPRIÉTAIRE GUIDE DE RÉPARATION AVANT DE TENTER UNE RÉPARATION TOUTES LE MESURES DE SÉCURITÉ DOIVENT ÊTRE RESPECTÉES CAUTION RISK OF FIRE OR EXPLOSION DUE TO PUNCTURE OF REFRIGERANT TUBING FOLLOW HANDLING INSTRUCTIONS CAREFULLY FLAMMABLE REFRIGERANT USED ATENCION RIESGO DE INCENDIO O EXPLOSIÓN DEBIDO A LA PERFORACION DE LA TUBERÍA REFRIGERANTE SIG...

Страница 3: ...n Guides Install the unit on a strong and leveled surface If the surface is uneven the unit may be noisy The unit may malfunction if the surface is uneven Install the unit in an indoor well ventilated area For best performance maintain 6 of clearance on the front and the back of the unit at all times Outdoor use may cause decreased efficiency and damage to the unit Avoid direct sunlight Avoid inst...

Страница 4: ...imum temperatures for food safety and should require no adjustments Refrigerators are set to cycle between a minimum temperature of 33 degrees Fahrenheit and a maximum temperature of 40 degrees Fahrenheit Freezers are set to cycle between a minimum temperature of 5 degrees Fahrenheit and a maximum temperature of 2 degrees Fahrenheit Adjusting the temperature changes the minimum temperature your un...

Страница 5: ...automatically initiate at pre set intervals and for a pre determined duration Operation Maintenance NOTE We strongly recommend that any servicing be performed by an authorized service technician Loading Product Do not block the coil Ensure all shelves are sitting level and properly secured before loading products Do not store flammable and explosive gas or liquids inside the unit Cleaning the Cond...

Страница 6: ... too high Set thermostat to lower temperature Airflow is blocked Re arrange products to allow for proper air flow Low refrigerant levels Contact a service technician to check refrigerant levels Door is slightly ajar Make sure door is completely closed Interior Light is Not Working Poor switch connection Turn off light switch and turn it back on Bulb is not connected Make sure the bulb is correctly...