background image

1. Use mild liquid detergent and soft cloth for daily cleaning. Do not use a detergent with acetone 

or ammonia. Disinfector with formic acid and formaldehyde is forbidden during disinfection. 

2. Screw of the water circulation and jets for cleaning when plug up by litter such as hair.
3. If there is a scratch on the bathtub surface, please use 2000# waterproof abrasive paper to 

polish it, put a bit of toothpaste before doing it. After that, use cloth to polish it.

4. Stone and stains can be wiped off by warm citric acid egg. Lemon juice or vinegar with a soft 

cloth.

5. Do not clean the bathtub with hard or coarse material to avoid any scratches, as well as with 

chemical solvent to avoid any damages.

6. Be sure to drain the water off and disconnect the power supply after each use.

7. Do not hit and score the bathtub by hard or keen-edged material. Do not touch the bathtub by 

cigarettes ends or any heating source over 70C degrees. 

8. Water massage cleaning system: fill in the bathtub with 40C of hot water, add detergent (2g/L). 

Then run the water massage system for 5 minutes. After that stop the pump and drain it off. Fill 
the bathtub with cold water and run the massage system for 3 minutes. Finally clean the bathtub
one more time after stopping the pump and draining off the water.

Precautions

1. The installation should be carried out by a qualified technician and should be done according to 

the manual.

2. The bathtub electric parameter should be equivalent with the National Safety Standards. There 

should be electric leakage protector on the power supply. Make sure the ground wire is safe. 
Protect the switch, electrical outlet and plug from water.

3. Do not put very hot water directly in the start of your bath, please start with cold water, after 

that, switch it to warm. Do not turn on the massage option until the water level is high enough 
to cover the jets.

4. The rated voltage of this bathtub is 220V. Do not run it when the voltage is over 235V or under 

190V.

5. Disconnect from power supply after each use.

6. Taking a bath for more than 30 min may be harmful to your health. 
7. Please restart the bathtub for occasional problems with the system.

8. If the supply core is damaged it must be replaced by the manufacturer, service agent or similarly 

qualified person in order to avoid hazard. 

9. This manual is attached with the product, please read it carefully before the installation. Usage 

of this bathtub should be according to this manual to avoid damage or other accidents.

Usage of the Product

10

Содержание MONACO

Страница 1: ...ches do not hit or rub against the bathtub with a hard object 4 To avoid stumbling please pay attention to the drop height while entering the bathtub 5 Please pay double attention in case of wet surface with soapsuds 6 Do not use any acidic and strong alkaline acetone ammonia detergent as well as any other which can cause corrosion Clean it with a soft cloth and a mild detergent suitable to use on...

Страница 2: ...Please use tools to open this parcel Make sure all accessories are inside the packing 2 ...

Страница 3: ...s and procedures 3 User should install an electric leakage protector on the power supply Power lines must be checked and connected with a good ground line The section of the electrical wire should not be less than 2 5m2 The power supply appliance should be in accordance with the National Safety Standard 4 WARNING While using electrical devices basic precautions should be followed by user 5 DANGER ...

Страница 4: ...Installation of water supply Installation Process 4 ...

Страница 5: ...s need to install the faucet according to basic procedures after that connect the cold hot water hose to the corresponding water supply tube which should be in the shelter of the bathtubs back A Waterfall B Handheld Shower C Switch for Shower and Faucet D Temperature Adjuster Installation of Bathtub 5 ...

Страница 6: ...1 Please lay the bathtub upside down and wrap the drainer with thread PTFE tape then screw the drainer Please see the drawing below Installation of Bathtub 6 ...

Страница 7: ...d shower after that connect to the water hose intake 3 Adjust the tub feet to make it horizontal Move the bathtub to the wall corner Put the drainer to the sewer and seal the drainer with a sealant Seal the gap between the bathtub and the wall with sealant to avoid water leakage 7 ...

Страница 8: ... head 3 Do not press the water pump switch unless the water level in the bathtub is above the jets position 4 Use air regulator to adjust the massage power 5 Rotate the handheld shower to adjust the massage effect 6 Light turns on and changes automatically when you turn on the pump It turns off when you turn off the pump 7 Press pneumatic switch turn off the pumps and drain the water out after use...

Страница 9: ...switch is set on OFF Problems with power supply plug not enough power to supply the bathtub Water pump faulted Turn on the power supply and connect the leakage protector Clean the water pump impeller Press the water pump switch Check the plug in case it is turned off if yes plug it back in Repair or replace the water pump MASSAGE POWER CANNOT BE ADJUSTED Electric voltage problem Air regulator swit...

Страница 10: ...d run the massage system for 3 minutes Finally clean the bathtub one more time after stopping the pump and draining off the water Precautions 1 The installation should be carried out by a qualified technician and should be done according to the manual 2 The bathtub electric parameter should be equivalent with the National Safety Standards There should be electric leakage protector on the power sup...

Страница 11: ...mp state display E Remote control receiving window F Ozone status display G Constant temperature state display AA 07 Remote Control Description 1 ON OFF 2 Waterfall button 3 CD connector button 4 Volume up or function adjustment button upwards 5 Volume down or function adjustment button downwards 6 Telephone button 7 Water pump button 8 Ozone pasteurize 9 Radio 10 Radio channel switching and stori...

Страница 12: ...ther frequency you need to press the FUN button which will go into search status By using and buttons you can pick the frequency by yourself by holding them for a longer period of time egg 5 seconds it will go into automatic search of the nearest frequency To save the frequency channel please press M button to store it Pressing button twice in a row will switch from one saved channel to another It...

Страница 13: ...t the ozone function and it will last for 15 minutes After those 15 minutes the function will stop automatically Pressing it once again while the timer is still on will turn off the function earlier than after 15 min You can see on the display how much time is left when the function is on 9 Waterfall Pressing the waterfall button on the display panel or remote control will turn on the waterfall fu...

Страница 14: ...14 ...

Отзывы: