EMX-H61B User
’s Manual
36 EMX-H61B
User’s Manual
Item
Option
Description
Serial Port
Disabled
Enabled
[Default]
Enable or Disable Serial Port
(COM).
Change Settings
Auto
[Default]
IO=2F8h; IRQ=3;
IO=3F8h; IRQ=3,4,5,6,7,9,10,11,12;
IO=2F8h; IRQ=3,4,5,6,7,9,10,11,12;
IO=3E8h; IRQ=3,4,5,6,7,9,10,11,12;
IO=2E8h; IRQ=3,4,5,6,7,9,10,11,12;
Select an optimal setting for
Super IO device.
3.6.2.7 HW Monitor
The H/W Monitor shows the operating temperature, fan speeds and system voltages.
Item
Options
Description
Smart Fan 1 Mode
Full on Mode
Automatic Mode
[Default]
Smart Fan 1 Mode Select.
Fan off temperature limit
0-127
Fan will off when temperature lower than this
limit. [0-127]
Fan start temperature limit
0-127
Fan will work when temperature higher than
this limit. [0-127]
Fan start PWM
0-255
Fan will stat with this PWM value. [0-255]
PWM SLOPE SETTING
0-127
PWM SLOPE Value. [0-127]
Содержание EMX-H61B series
Страница 10: ...EMX H61B User s Manual 10 EMX H61B User s Manual 2 Hardware Configuration...
Страница 11: ...EMX H61B User s Manual EMX H61B User s Manual 11 2 1 Product Overview...
Страница 12: ...EMX H61B User s Manual 12 EMX H61B User s Manual...
Страница 24: ...EMX H61B User s Manual 24 EMX H61B User s Manual 2 4 17 DC power in connector DCIN...
Страница 25: ...EMX H61B User s Manual EMX H61B User s Manual 25 3 BIOS Setup...
Страница 49: ...EMX H61B User s Manual EMX H61B User s Manual 49 Step 7 Select Finish to complete installation...
Страница 51: ...EMX H61B User s Manual EMX H61B User s Manual 51 5 Mechanical Drawing...
Страница 52: ...EMX H61B User s Manual 52 EMX H61B User s Manual Unit mm...
Страница 53: ...EMX H61B User s Manual EMX H61B User s Manual 53 Unit mm...
Страница 54: ...EMX H61B User s Manual 54 EMX H61B User s Manual Unit mm...