To register your TRAVIS INDUSTRIES, INC. 7 Year Warranty, complete the enclosed warranty card and mail it within ten (10) days of the appliance

purchase date to: TRAVIS INDUSTRIES, INC., 4800 Harbour Pointe Blvd. SW, Mukilteo, WA  98275.  TRAVIS INDUSTRIES, INC. warrants this gas
appliance (appliance is defined as the equipment manufactured by Travis Industries, Inc.) to be defect-free in material and workmanship to the original
purchaser from the date of purchase as follows:

Check with your dealer in advance for any costs to you when arranging a warranty call.

Mileage or service charges are not covered by this warranty. This charge can vary from store to store.

Years 1 & 2 - COVERAGE: PARTS & LABOR

Firebox Assembly:

Firepot, Firepot Holder, Ash Cleanout Doors, Ashbox or Ash
Dump, Cast Fireback, Heat Exchanger Tubes, Exhaust
Manifold, Exhaust Box

Door Assembly:

Door Frame, Latch Assembly, Glass Retainers

Auger Assembly

Auger Flight, Auger Tube, Auger Bushings

Ceramic Glass

Glass (breakage from thermal shock)

Igniter System

Igniter, Igniter Leads

Electrical System

Auger Motor, Convection Blower, Exhaust Blower, Circuit
Board, Snap Disks, Wiring Harness, Vacuum Switch

Accessories

Panels, Legs, Pedestal, Gold Trim, Ceramic Log with Log Shelf,
Gold Door (See # 9 below)

Re-Installation Allowance

In cases where heater must be removed from home for repairs, a
partial cost of re-installation is covered (pre-authorization required)

One-Way Freight Allowance

One-way freight allowance on pre-authorized repair done at factory
is covered.

Exclusions:

Paint, Gasketing

Years 3 Through 5 - COVERAGE: PARTS & LABOR

Firebox Assembly:

Firepot, Firepot Holder, Ash Cleanout Doors, Ashbox or Ash
Dump, Cast Fireback, Heat Exchanger Tubes, Exhaust
Manifold, Exhaust Box

Door Assembly:

Door Frame, Latch Assembly, Glass Retainers

Auger Assembly

Auger Flight, Auger Tube, Auger Bushings

One-Way Freight Allowance

One-way freight allowance on pre-authorized repair done at
factory is covered.

Exclusions:

Paint, Gasketing, Ceramic Glass, Igniter System, Electrical System, Accessories (panels, legs, pedestal, gold trim, ceramic log, gold
door), Re-Installation Allowance

Years 6 & 7 - COVERAGE: PARTS ONLY

Firebox Assembly:

Firepot, Firepot Holder, Ash Cleanout Doors, Ashbox or Ash Dump, Cast
Fireback, Heat Exchanger Tubes, Exhaust Manifold, Exhaust Box

Door Assembly:

Door Frame, Latch Assembly, Glass Retainers

Exclusions:

Paint, Gasketing, Ceramic Glass, Igniter System, Electrical System, Accessories (panels, legs, pedestal, gold trim, ceramic log, gold
door), Auger Assembly, Re-Installation Allowance, One-Way Freight Allowance, Labor

CONDITIONS & EXCLUSIONS

1.

This new  appliance must be installed by a qualified installer.  It must be installed, operated, and maintained at all times in accordance with the instructions in
the Owner’s Manual.  Any alteration, willful abuse, accident, neglect, or misuse of the product shall nullify this warranty.

2.

This warranty is nontransferable, and is made to the ORIGINAL purchaser, provided that the purchase was made through an authorized Travis dealer.

3.

Discoloration and some minor expansion, contraction, or movement of certain parts and resulting noise, is normal and not a defect and, therefore, not covered
under warranty.

4.

The warranty, as outlined within this document, does not apply to the chimney components or other Non-Travis accessories used in conjunction with the
installation of this product. If in doubt as to the extent of this warranty, contact your authorized Travis retailer before installation.

5.

Travis Industries will not be responsible for inadequate performance caused by environmental conditions such as nearby trees, buildings, roof tops, wind, hills
or mountains or negative pressure or other influences from mechanical systems such as furnaces, fans, clothes dryers, etc.

6.

This Warranty is void if:
a.

The unit has been operated in atmospheres contaminated by chlorine, fluorine or other damaging chemicals.

b.

The unit is subject to submersion in water or prolonged periods of dampness or condensation.

c.

Any damage to the unit, combustion chamber, heat exchanger or other components due to water, or weather damage which is the result of, but not limited
to, improper chimney/venting installation.

7.

Exclusions to this 7 Year Warranty include:  injury, loss of use, damage, failure to function due to accident, negligence, misuse, improper installation,
alteration or adjustment of the manufacturer's settings of components, lack of proper and regular maintenance, damage incurred while the appliance is in
transit, alteration, or act of God.

n

 

This 7 Year warranty excludes damage caused by normal wear and tear, such as paint discoloration or chipping, worn or torn gasketing, chipped

or cracked firebrick, etc.  Also excluded is damage to the unit caused by abuse, improper installation, modification of the unit, or the use of fuel other than  that
for which the unit is configured.

n

 

Damage to gold or nickel surfaces caused by fingerprints, scratches, melted items, or other external sources left on the gold  or nickel from the

use of cleaners other than denatured alcohol  is not covered in this warranty.

10.

TRAVIS INDUSTRIES, INC. is free of liability for any damages caused by the appliance, as well as inconvenience expenses and materials.  Incidental or
consequential damages are not covered by this warranty.  In some states, the exclusion of incidental or consequential damage may not apply.

11.

This warranty does not cover any loss or damage incurred by the use or removal of any component or apparatus to or from the Travis appliance without the
express written permission of TRAVIS INDUSTRIES, INC.  and bearing a TRAVIS INDUSTRIES, INC. label of approval.

12.

Any statement or representation of Travis products and their performance contained in Travis advertising, packaging literature, or printed material is not part of
this 7 year warranty.

13.

This warranty is automatically voided if the appliance’s serial number has been removed or altered in any way. If the appliance is used for commercial
purposes, it is excluded from this warranty.

14.

No dealer, distributor, or similar person has the authority to represent or warrant Travis products beyond the terms contained within this warranty.  TRAVIS
INDUSTRIES, INC. assumes no liability for such warranties or representations.

15.

Travis Industries will not cover the cost of the removal or re-installation of hearths, facing, mantels, venting or other components.

16.

 

If for any reason any section of this warranty is declared invalid, the balance of the warranty remains in effect and all other clauses shall remain in effect.

17.

This 7 year warranty is the only warranty supplied by Travis Industries, Inc., the manufacturer of the  appliance.  All other warranties, whether express or
implied, are hereby expressly disclaimed and purchaser’s recourse is expressly limited to the warranties set forth herein.

IF WARRANTY SERVICE IS NEEDED:

1.

If you discover a problem that you believe is covered by this warranty, you MUST REPORT it to your Travis dealer WITHIN 30 DAYS, giving them proof of purchase, the purchase date, and the
model name and serial number.

2.

Travis Industries has the option of either repairing or replacing the defective component.

3.

If your dealer is unable to repair your appliance’s defect, he may process a warranty claim through TRAVIS INDUSTRIES, INC., including the name of the dealership where you purchased the
appliance, a copy of your receipt showing the date of the appliance’s purchase, and the serial number on your appliance.  At that time, you may be asked to ship your appliance, freight charges prepaid,
to TRAVIS INDUSTRIES, INC.  TRAVIS INDUSTRIES, INC., at its option, will repair or replace, free of charge, your  appliance if it is found to be defective in material or workmanship within the
time frame stated within this 7 year warranty.  TRAVIS INDUSTRIES, INC. will return your appliance, freight charges (years 1 to 5) prepaid by TRAVIS INDUSTRIES, INC., to your regional
distributor, or dealership.

4.

Check with your dealer in advance for any costs to you when arranging a warranty call.  Mileage or service charges are not covered by this warranty. This charge can vary from store to
store.

Содержание Astoria

Страница 1: ...w these instructions could result in property damage bodily injury or even death Contact local building or fire officials about restrictions and installation inspection requirements in your area Tested and Listed by OMNI Test Laboratories Inc Beaverton Oregon Report 028 S 42 2 ASTME 1509 1995 ULCC 1482 Owner s Manual Installer After installation give this manual to the home owner and explain opera...

Страница 2: ...will make the installation and operation of your new heater an easier and more enjoyable experience We offer our continual support and guidance to help you achieve the maximum benefit and enjoyment from your heater Important Information No other Astoria heater has the same serial number as yours The serial number is on the hopper lid This serial number will be needed in case you require service of...

Страница 3: ...Freestanding Masonry Chim 18 Operation Safety Notice 19 Location of Controls 19 Starting the Heater for the First Time 19 Curing the Paint 19 Priming the Auger 19 Loading Pellets 20 The Two Modes of Operation 20 Operation continued Manual Mode 21 Auto Mode 22 Restrictor Adjustment 23 Adjusting the Fan Speed 23 Start Up Sequence 24 AUGER ON Light 24 FAULT Light 24 Power Outages 24 Maintenance Daily...

Страница 4: ... Do not use makeshift methods or compromise in the installation Never try to repair or replace any part of the heater unless instructions are given in this manual All other work should be done by a trained technician Your heater requires periodic maintenance and cleaning see Maintaining Your Heater Failure to maintain your heater may lead to smoke spillage in your home The viewing door and ashpan ...

Страница 5: ...TE Turning the Mode Switch to OFF does not disconnect all power to the heater The exhaust system should be checked twice a year minimum for any build up of soot or creosote This Manual Do not throw this manual away This manual has important operating and maintenance instructions that you will need at a later time Always follow the instructions in this manual Do not touch the hot surfaces of the he...

Страница 6: ...8 This tab is for the scraper rod tool Electrical Specifications Electrical Rating 115 Volts 3 6 Amps 60 Hz Watts During Start Up Sequence 400 approximately Watts During Operation 180 approximately Fuel The unit is designed for wood pellets that comply with the standards set by the Association of Pellet Fuel Industry density of at least 40 lbs per cubic foot 1 4 to 5 16 diameter length no greater ...

Страница 7: ...ove locate the wall studs for horizontal penetrations and ceiling trusses for vertical penetrations You may wish to adjust the stove position slightly to ensure the vent does not intersect with a framing member HINT Place the heater outside and load 10 pounds of pellets inside the hopper Plug the heater in and let it run on HIGH until the pellets run out This will cure the paint and burn off any o...

Страница 8: ...AAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA 6 Minimum AAAAAAAAAAAAA AAAAAAAAAAAAA AAAAAAAAAAAAA AAAAAAAAAAAAA AAAAAAAAAAAAA AAAAAAAAAAAAA AAAAAAAAAAAAA AAAAAAAAAAAAA AAAAAAAAAAAAA AAAAAAAAAAAAA AAAAAAAAAAAAA AAAAAAAAAAAAA AAAAAAAAAAAAA Through the Wall Vents A A A AA AA AA 3 Minimum 45 Elbow 45 3 Minimum Interior Vertical Vents 3 Minimum 6 Minimum 2 Mini...

Страница 9: ...LINGS MAKE SURE TO MAINTAIN 3 CLEARANCE TO ANY COMBUSTIBLES No more than one tee and 180 of elbows one tee with two 90 elbows one tee with one 90 and two 45 elbows etc Maximum Venting Distance Vent must have a support bracket every 5 of pellet vent when exterior of structure 0 Feet 5 Feet 10 Feet max 0 Feet 5 Feet 10 Feet 15 Feet 20 Feet 25 Feet 30 Feet 33 Feet max The vent height and run must not...

Страница 10: ...f the house an approved house shield is recommended to prevent soot from building up on the side of the house Must not be located where it will become plugged by snow or other material Horizontal terminations must protrude 12 from the wall verticall terminations require 24 H G A D F NOTE Measure clearances to the nearest edge of the exhaust hood A E B C F X A Minimum 4 clearance below or beside an...

Страница 11: ...d We recommend the Travis Industries Outside Air Kit part 99200136 Must not terminate above or within 1 of the chimney termination Must have a rain cap or down turned elbow to prevent water from entering Must be located so that it will not become plugged by snow or other material Air Inlet 1 3 4 Outside Diameter A A 1 2 Center Line AA AA AA AA A A AA AA AA AA AA A A AAA AAA AAA AA AA AA AA AA AA A...

Страница 12: ...firebox Altitude vent configuration and other factors make restrictor adjustment necessary for every installation NOTE the optimal restrictor position will vary over time as soot builds up inside the exhaust system make sure the homeowner knows how to visually inspect the flame and adjust the restrictor Not Enough Air If clinkers develop or the flame appears lazy and slow to blow the ash out of th...

Страница 13: ...A 12 Minimum Horizontal Rain Cap Wall Thimble note 3 clearance between vent and combustibles Outside Air Type L Vent 12 Minimum A A A A A A A A A A A A AAAAAAAAAAAAAAA AAAAAAAAAAAAAAA AAAAAAAAAA AA AA AA AA AA AA AA AA AA AA AA 3 Minimum 17 5 8 10 1 2 Floor Protection Seal each vent section including adapters elbows etc by injecting a liberal amount of 500 F RTV silicone into the gap between secti...

Страница 14: ...AAAA AAAAAAAAAAAAAA AAAA AAAA AAAA AAAA AAAAAAAAAAAAA AAAAAAAAAAAA AA AA AA AA AA AA AA AA AA AA AA AA AA AA Floor Protection AA AA AA AAAAAAA AAA AA AA AAAAAAA AAAAAAA AAAAAAA 24 Minimum Insulation must maintain 3 clearance Outside air may be drawn from a ventilated crawl space 2 Min 3 Min Ceiling Support Fire Stop Spacer Roof Flashing Storm Collar Vertical Cap Vent must maintain 3 clearance to c...

Страница 15: ...AAAAAAAAA AAAA AAAA AAAA AAAA AAAA AAAAAAAAAAAAAAAAA AAAAAAAAAAAAAA A A A A A A A A A A A A A A A A Floor Protection AA AA AA AAAAAA AAAAAA AAAAAA AAAAAA AA AA AA Outside air may be drawn from a ventilated crawl space 2 Min 3 Min Class A Chimney Ceiling Support Roof Flashing L Vent to Class A Chimney Adapter Class A Chimney L Vent AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAAAA AAAAAA AAA...

Страница 16: ... AA AA AA AA AA AA AA AA AA AA AA AAA AAA AA AA AA AA AA AA AA AA AA AAA AAA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AAA AAA AAA AAA AAA AAA AAA AAA AAA AAA AA AA AA AA AA AAAAA AAAAA AAA AAA AAAA AAAA AAA AA Storm Collar Vertical Cap Cover Plate non combustible Silicone Seal the cover plate with silicone AAAA AA...

Страница 17: ...A AAAA AAAA AAAA AAAA Storm Collar Vertical Cap Cover Plate non combustible Silicone Seal the cover plate with silicone NOTE you will probably need a short horizontal section here to clear the lintel and allow the hopper lid to open AAAAA AAAAA AAAAA AAAAA AAAAA Allow room for the hopper lid to open 57 1 2 3 AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA Seal each vent section including adapters elbows e...

Страница 18: ...A AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AA AAAAAAAAAAAAAAAAAA AA AA AA AA AA AA A...

Страница 19: ...IM ER MIN Tim e Set Tim e Can cel A u t o 50 60 70 80 90 50 60 70 80 90 Robertshaw Restrictor The restrictor adjusts the amount of air flowing to the flame Starting the Heater for the First Time Start the Heater Let it Burn for 1 Hour THEN OPEN THE DOOR The stove paint is cured through heat To prevent it from bonding to the door gasket you must burn the heater for approximately 1 hour then open an...

Страница 20: ...requires the user to turn the heater on and off manually Auto requires a thermostat Auto mode allows you to use a thermostat to control room temperature The stove automatically turns on when the temperature drops below the thermostat setting Once the stove reaches operating temperature the stove then runs at the heat output setting selected Switching Modes While in Operation Whenever the stove is ...

Страница 21: ...NUAL START AUGER TRAVIS INDUSTRIES HOUSE OF FIRE TM To Shut Down Move the mode switch to OFF The exhaust blower will still run until the heater cools down AUTO OFF MANUAL H E A T F A N UP DOWN UP DOWN MANUAL MANUAL START AUGER TRAVIS INDUSTRIES HOUSE OF FIRE TM To Adjust the Heat Press the Heat buttons to adjust the heat output NOTE During start up you may adjust the heat setting This heat setting...

Страница 22: ...djust the heat output HINT If you find that the stove turns on and off repeatedly you may wish to turn the heat output to a lesser setting The lower setting will provide a more consistent heat output over time eliminating the need for the thermostat to repeatedly turn the stove off NOTE If the thermostat calls for heat while the stove is still cooling down the stove will go through the start up se...

Страница 23: ...5 yet the firepot does not remain clean the stove needs to be cleaned and checked for air leaks see Maintenance section of this manual Too Much Air If the flames are too active small flickering flames or if burning pellets are expelled from the firepot move the restrictor rod inwards until the flame slows down and no burning pellets are expelled Another symptom of too much air is the heater blowin...

Страница 24: ...urs The stove runs out of pellets During initial start up for a split second or for improper electrical frequency A start up sequence that does not result in the heater coming up to temperature To reset the fault light turn the mode switch to off and re start the stove HIGH DISCONNECT POWER BEFORE SERVICE REMOTE AUTO MANUAL H E A T O U T P U T MED LOW AUGER FAULT Fault Codes for qualified service ...

Страница 25: ... adjustment see Restrictor Adjustment in the installation section of this manual The door glass or ashpan is open or has an air leak The firepot requires cleaning The exhaust system requires cleaning AA AA A A A A A AA AA AA A AA A A A A A A AA A A A A A A A AA A A A AA AA AA A A A A A A A A A A A A A A A AA A A A AA AA AA A A A A A AA AA AA AA AA AA A A AA A AA AA A AA AA A A A A A A AA AA AA A A...

Страница 26: ... A A A A A A A A A A A A AA AA AA AA A A A A A A A A AA A A AA A A A A A A A A A AA AA A A A A A A A A A A A A A A AA AA AA AA A A AA AA AA AA A A A A A A A A A A A A A A A A A A A A A A A A A A A A A Cleaning the Firepot WARNING Make sure the heater has fully cooled approximately 25 minutes before opening the door and conducting service To clean the firepot open the door see page 27 and knock awa...

Страница 27: ...the pawl fits over the bracket before tightening NOTE Do not overtighten the pawl This can permanently damage the latch and prematurely wear out the door gasket Door Frame Bracket attached to side of heater Pawl Lock Nut AAAA AAAA AAAAAAAA AAAAAAAA AAAAAAAA AAAAAAAA AAAAAAAA AAAA AAAAAAA AAAAAAA AAAAAAA AAAAAAA Phillips Screwdriver With the pawl free of the bracket the door may be swung open ...

Страница 28: ...the stove With the door closed insert the included tool into the hole on the heat exchanger cleaning rod Move the heat exchange cleaner up and down several times Vacuum Hopper Run the stove until the pellets run out Open the hopper and vacuum out the entire hopper The dust and any other debris near the bottom should be removed to prevent excessive build up Cleaning the Optional Gold Surfaces Door ...

Страница 29: ...top of the baffle NOTE you do not need to remove the baffle from the firebox The firebox baffles install on ledges at the top of the firebox The two tabs at the outside back corners insert into notches at the right and left rear corners of the firebox walls The baffles install on ledges above the firebrick Air Tubes Firebrick AAA AAA AAAAAAA AAAAAAA AAAAAAA AAAAAAA AAAAAAA AAA AAAAAA AAAAAA AAAAAA...

Страница 30: ... its holder Slide the ash pan trap door forward to expose the ash dumps the door can be removed and cleaned if necessary Brush all flyash into the ash dumps including the flyash inside the firepot holder Replace the ash trap doors and firepot Slide the ash pan trap door forward WARNING The firebox becomes very hot during operation Let the stove cool completely before conducting service a f e d c b...

Страница 31: ... Ashes should be placed in a metal container with a tight fitting lid The closed container of ashes should be placed on a noncombustible floor or on the ground well away from all combustible materials pending final disposal If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container until all cinders have been thoroughly cooled Clea...

Страница 32: ... venting system The exhaust venting system should be inspected at least once every year to determine if cleaning is necessary Clean the Vertical Exhaust Duct the stove must be cool and unplugged Clean the refractory and the entire area behind it both sides Remove these doors to remove fallen flyash and soot see Bi Weekly Remove both refractory clips Clean the Exhaust Duct the stove must be cool an...

Страница 33: ...s Blower Housing Exhaust Box Phillips Screwdriver Restrictor Knob Clean the Vent make sure the stove and vent is cool Check the vent sections for creosote accumulation indicating a poorly burning stove Accumulation over 1 4 must be removed On vertically vented systems the dirtiest portion is often the point where the vent turns upwards i e the Tee Fortunately the Tee has a built in clean out cover...

Страница 34: ...mmend that you open the hopper lid and look down upon the door and body of the heater Use the illustration to the right to determine the correct door alignment Correctly Aligned Door When properly adjusted the door should be evenly spaced from the front of the stove and shut tight compressing the gasket AAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAA Top of Sto...

Страница 35: ...Loosen the lock nut and twist the pawl clockwise to tighten counter clockwise to loosen Tighten the lock nut to secure in place Door Bracket attached to side of heater Lock Nut Pawl Door Hinge Bracket Door Hinge Adjusting Plate Hinge Adjustment 1 With the door closed loosen the two bolts going through the door hinge bracket 2 Loosen the four nuts used to move the hinge adjusting plate Tighten or l...

Страница 36: ...3 GLASS SIDE P12 14 P13 91002005 AUGER DRIVE COLLAR 1997 UP 91002021 GROMMET IGNITOR WIRE BLACK RUBBER 100 02811 AUGER FLIGHT INSPECTION COVER 210 02702 GSKT CLEAN OUT CVR 3 250 x 2 750 100 03235 AUGER FLIGHT 2000 LRG PEL 91002013 GSKT COMB BLOWER BODY 100 03206 AUGER MOTOR STOP P11 P15 93005096 GSKT COMB BLOWER MOTOR 7 dia 100 03231 AUGER MOTOR ALL PS PI 90 0191 GSKT EXHAUST PLATE 4 25 x4 25 100 ...

Страница 37: ...ated air being forced through these tubes by the convection fan Firepot As pellets are fed into the firepot a light clicking sound may be heard Convection Fan The modern high efficiency fan may produce a low hum particularly on HIGH This sound will change as the FAN setting is changed Exhaust Blower This blower may create a low pitched hum This sound will change as the HEAT OUTPUT is altered ...

Страница 38: ...6 or equivalent Minimum Clearance to Combustible Materials Measured to Stove Top BACKWALL LEFT SIDEWALL FLOOR PROTECTOR A C H H B G E ADJACENT WALL ADJACENT WALL D D RIGHT SIDEWALL E Interior Vertical Horizontal Through Flue Installation the Wall Installation Left Sidewall A 9 9 Right Sidewall B 9 9 Backwall C 3 Corner D 3 3 Flue Vent E 3 3 Maximum alcove depth 48 in 1220 mm minimum ceiling height...

Страница 39: ... prolonged periods of dampness or condensation c Any damage to the unit combustion chamber heat exchanger or other components due to water or weather damage which is the result of but not limited to improper chimney venting installation 7 Exclusions to this 7 Year Warranty include injury loss of use damage failure to function due to accident negligence misuse improper installation alteration or ad...

Страница 40: ...of the 20 length of thermostat wire It should be centralized in the room and away from the heater The wire may be routed externally on the wall or behind the wall preferred 3 Follow the directions to the right to attach the thermostat and thermostat wires Attach the quick connects to the two posts near the molex connector on the circuit board orientation does not mater 50 60 70 80 90 50 60 70 80 9...

Страница 41: ...the log shelf following the directions below Right Log Shelf Leg Left Log Shelf Leg Log Shelf Cross Brace 3 8 Nutdriver Nuts 2 Remove the firepot from the pellet stove Center the log shelf assembly with extender attached over the burnpot holder Replace the burnpot Place the log on the log shelf extender When in place the log should appear as shown in the photograph to the right Center the log on t...

Страница 42: ...24 Firebox Cleaning 32 Fireplace Installation 16 Firepot Cleaning 26 Firepot Inspection Inspect the Burn 25 Flames Inspect the Burn 25 Floor Protection Requirements 7 Fuel 6 Gasket door glass inspection removal 36 Glass Cleaning 31 Glass Removal 36 Gold cleaning 28 Hearth Floor Protection Requirements 7 Hearth Fireplace 16 Heat Exchange Tubes cleaning 28 Heating Specifications 6 Hopper Cleaning Va...