background image

 

 

 

Operation

 

 

INSTALLATION CHECK‐LIST BEFORE OPERATION: 

1.

 

Have all packing materials and tape been removed from the interior and exterior of the beverage 
refrigerator? 

2.

 

Have the installation instructions been followed, including connecting the machine to electricity?  

3.

 

Has proper grounding been installed for the beverage refrigerator? 

4.

 

Has the machine been leveled? 

5.

 

Is the beverage refrigerator in a site where the ambient temperature is between 50° F and 90° F all year 
round? 

6.

 

Is there a clearance of at least 2” to 3” at the rear for proper air circulation? 

 

USING YOUR CONTROL PANEL: 

 

  

 

 
 
 
 
 

This beverage refrigerator has a temperature range from 34° F to 50° F. 

 Power Button  

Press and hold this button down for three seconds to power your unit on.  Once pressed, the “Run” 
indicator light will illuminate to indicate the unit is on and running.  Press and hold this button for three 
seconds again and the unit will power off and the “Run” Indicator light will turn off. 

 Increase Temperature 

Press this button to increase the temperature by one (1) degree increments.  50° F is the highest 
available temperature on this unit. 

 Decrease Temperature 

Press this button to decrease the temperature by one (1) degree increments.  34° F is the lowest 
available temperature on this unit.   

 Interior Light 

Press this button to cycle through the different internal light settings. There are four light settings: 
Constant Blue, Constant White, Automatic Blue, and Automatic White. Press this button to choose the 
next option in the progression, eventually cycling back to the original setting. The lights will fade out of 
the previous setting and into the next setting in the cycle each time you press this button. Press and hold 
this button for three seconds to turn the lights completely off or to turn them back on. Open and close 
the door to check the internal light color and whether the lights stay on with the door closed (Constant 
Mode) or illuminate only when the door is open (Automatic Mode). Please refer to the “Internal Light” 
section on the next page for further detail. 

Содержание AWBV15246

Страница 1: ...USER S GUIDE Installation Operation and Maintenance for your product Built In Beverage Refrigerator Model ABR241SGRH ABR241SGLH www avallon com 1 866 471 7427 V2 1 07102018 ...

Страница 2: ...h or pull chain Always turn the unit off and unplug it from the outlet when cleaning Unplug the unit if it is not going to be used for an extended period of time Do not operate the unit with a power plug missing the ground plug a damaged cord or a loose socket Be sure the beverage refrigerator is properly grounded Never plug or unplug the unit with wet hands Do not bypass cut or remove the groundi...

Страница 3: ...oors and protected from rain sleet snow and or moisture Never allow children to crawl inside the beverage refrigerator If you are disposing of the unit remove the door Do not use this appliance near flammable gas or combustibles such as gasoline benzene thinner etc Do not place the unit near heat sources such as ovens grills or direct sunlight Only use in an upright position on a flat level surfac...

Страница 4: ...rance Requirements 4 LEVELING 5 RECOMMENDED GROUNDING METHOD 5 Installing Your Door Handle and Shelves 5 INSTALLING THE DOOR HANDLE 5 INSTALLING THE SHELVES 6 REMOVING THE SHELVES 6 Operation 7 INSTALLATION CHECK LIST BEFORE OPERATION 7 USING YOUR CONTROL PANEL 7 Power Button 7 Increase Temperature 7 Decrease Temperature 7 Interior Light 7 Internal Light 8 Constant Mode 8 Automatic Mode 8 Defrosti...

Страница 5: ...advised that you keep the original box and packaging materials in case you need to move or ship the appliance in the future Allow the unit to stand for at least 24 hours before you use it this allows the cooling components time to settle from transit The instruction manual should be read before use This owner s manual is provided for reference use only Specifications may change without prior notic...

Страница 6: ... rating label on the back of your unit and are needed to obtain warranty service You may also want to staple your receipt to this manual as it is the proof of your purchase and is also needed for service under your warranty Model Number Serial Number Date of Purchase To better serve you please do the following before contacting customer service If you received a damaged product immediately contact...

Страница 7: ...2 Parts Identification Full View Empty View ...

Страница 8: ... the compressor s oils to settle Note The carbon filter should be replaced every 3 6 months depending on the unit s exposure level to odor If the unit is placed in a kitchen regular replacement every three 3 months is ideal Tip Gather the model and serial number from the product label and write them down before installing the beverage refrigerator Warning Use two or more people to move and install...

Страница 9: ...erage refrigerator in front of the installation location 2 Adjust the feet and place the unit flat on the floor or on a platform depending on your installation requirements 3 If the electrical outlet for the beverage refrigerator is behind the cabinet plug in the beverage refrigerator 4 Push the beverage refrigerator into position 5 Installation Clearance Requirements When installing the beverage ...

Страница 10: ...ptacle installed by a qualified electrician Before you move your beverage refrigerator into its final location it is important to make sure you have the proper electrical connection A standard electrical supply 115 V 60Hz properly grounded in accordance with the National Electrical Code and local codes and ordinances is required It is recommended that a separate circuit serving only your beverage ...

Страница 11: ...backwards smoothly REMOVING THE SHELVES 1 Open the door completely 2 Make sure the shelf is pushed back completely 3 Lift either the left or right side of the shelf to create a 45 angle from its original position Make sure not to lift either side of the shelf too hard as it may come in contact with the inner wall mount 4 Pull the shelf outward until it is removed from the inner compartment You may...

Страница 12: ...the Run Indicator light will turn off Increase Temperature Press this button to increase the temperature by one 1 degree increments 50 F is the highest available temperature on this unit Decrease Temperature Press this button to decrease the temperature by one 1 degree increments 34 F is the lowest available temperature on this unit Interior Light Press this button to cycle through the different i...

Страница 13: ...h each press of the light button the unit will progress through the cycle of light settings seen below Holding the light button for three seconds will turn the lights completely off or back on If you power the lights off they will remain off even when the door is open Hold the light button for three seconds again to turn the lights back on Note Pressing and holding the increase and decrease temper...

Страница 14: ... create a consistent internal temperature environment Water running from the evaporator to the water bin may make a splashing sound As each cycle ends you may hear a gurgling sound due to the refrigerant flowing in your beverage refrigerator You may hear air being forced over the condenser by the condenser fan Cleaning and Maintenance Periodic cleaning and proper maintenance will ensure efficiency...

Страница 15: ... of times the door is opened The door is not completely closed Make sure the door is completely closed The door gasket is not sealing properly Make sure the door gasket is properly sealed The refrigerator does not have the suggested ventilation Read and follow the Installation Clearance Requirements section The beverage refrigerator does not turn on There is a power failure Ensure the refrigerator...

Страница 16: ...igerator is level and that it is not in contact with another appliance or furniture The body of the beverage refrigerator is electrified The unit is not properly grounded Contact your local electrician to test your electrical grounding system Frost is forming in the beverage refrigerator The environment is humid Through the unit uses an auto defrost system under certain conditions manual defrostin...

Страница 17: ...4 F to 50 F DIMENSIONS HEIGHT X WIDTH X DEPTH 34 1 2 X 23 13 16 X 25 3 8 WEIGHT 114 Pounds Storage capacity is based on standard 12 oz cans The refrigerator may experience decreased cooling efficiency when fully loaded Depth includes handle Depth without handle is 23 11 16 Note Technical data and performance information are provided for reference only Specifications are subject to change Check the...

Страница 18: ...s or replacement of parts designed to be replaced e g filters cartridges batteries Service trips to deliver pick up or repair install the product or to instruct in proper usage of the product Damages or operating prob lems resulting from misuse abuse operation outside environ mental specifications uses contrary to instructions provided in the owner s manual accidents acts of God vermin fire flood ...

Отзывы: