AVAIR AV-201 Скачать руководство пользователя страница 2

INSTALLATION 

 

To install the AV-201 or AV-601 simply connect coaxial cable directed to the antenna connector marked “ANT”,and   

  The cable coming from the transmitter or from the linear amplifier to the connector marked “TX” 

  AV-201/or AV-601 is ready to operate. 

 

POWER MEASUREMENTS   

  1 Select the RANGE (3) switch on the end-scale position value as to the power of the unit 

  2 Select the FUNCTION (4) switch in the power position   

  3 Select the POWER switch the FWD position to measure the direct power(from the radio to antenna) 

   or REF position to measure the reflected power(from antenna to the radio) 

  4 Select the power value can be read on the corresponding scale. 

  SWR MEASUREMENTS   

1 Select the RANGE (3) switch on the end-scale position value as to the power of the unit. 

2 Select the FUNCTION (4) switch in the CAL position . 

3 Let the radio transmit and adjust the instrument by turning the CAL knob, position the end-scale index in the 

  CAL position. 

4 Select the FUNCTION (4) switch in the SWR position 

5 Read the SWR value in the above scale.     

    

FIG5 (FOR  AV-201)                                        FIG6 (FOR AV-601 )  

 

         

    

 

 

 

 

       

  TO ANT            TO RADIO                   TO ANT   TO RADIO   TO RADIO      TO ANT 

            (1.8-160MHZ)OR(140-525 MHZ) 

                 

(1.8-160MHZ)         AV-601 (140-525 MHZ)

                                                                                       

REMARK: SWR VS. REFLECT POWER 

 

                                   Pfwd  +  Prev        

  SWR  1.0  1.1  1.2   1.5   2.0  2.5  3.0 

SWR (STANDING WAVE RATIO)= 

                                   Pfwd  -  Prev         

Prev

%   

0  0.22  0.8   4   11.1  8.4  25.0 

 

SPECIFICATION 

FREQUENCE RANGE: ………...1.8~160 MHZ(AV-201,AV-601 ,) , 140~525 MHZ (AV-401,AV-601)   
POWER MEASURE RANGE :….0.5~1KW(5W/20W/200W/1KW ) FOR    AV-201 AND AV-601 HF BAND 

1KW input condition (1KW 10 SECONDS ON    50 SECONDS OFF) if continuous 1KW input will burn the sensor . 

POWER MEASURE RANGE :….0.5~400W(5W/20W/200W ) FOR    AV-601 UHF BAND 

400W input condition (400W 25 SECONDS ON 35 SECONDS OFF) if continuous 400W input will burn the sensor . 

MINIMUN POWER INPUT :.…..0.5W  

Maximum continuous input 200W

 

PRECISION………………………5W RANGE 

±

5% , 20W RANGE 

±

7.5% , 200W RANGE 

±

10% , 400W RANGE 

±

12.5%   

1KW RANGE 

±

15% 

SWR:……………………..………. 1~INFINITY    
IMPDANCE:……………………...50ohm   
INPUT LOSS:……………………..0.2db (1.8~160 MHZ) , (140~525MHZ) , 0.3db(430-1300MHZ) 
DEMISION:…………………….…15X6.5X10CM     
WEIGHT:……………………….…720gr.(AV-601) , 630gr.(AV-201)   

 