Wiring diagram
Note:
•
A shielded cable is recommended to be used. The shield is connected to controller 0V reference
•
Maximum wiegand data cable length: 150 meters (500 feet)
•
Buzzer and LED are low activated.
•
RS485 and Relay are only for optional use. Specific setting is required to enable these functions.
•
I
nsulate all un-used wires
(
d
o not terminate).
Regulatory Information
C-Tick
: This device is C-Tick complied.
CE
: The device has passed all relevant tests and obtained CE approval.
FCC
: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) this device may
not cause harmful interference and 2) this device must accept any interference received, including interference that may cause
undesired operation of the device.
Warning: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of
the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications not expressively approved by BQT Solutions could void the user
’
s authority to operate this
equipment.
Specifications
Output protocols
Wiegand or RS485
Model
BioX
BioXK
Power requirement
8VDC
to
1
6
VDC (
n
ominal operating voltage 12VDC)
Current consumption
(12V DC)
280
mA (
Average
)
350
mA (Peak)
280
mA (
Average
)
380
mA (Peak)
Relay Rating
80mA
Read range
20
mm to
40mm (0.
8”
to
1.6
”
) at 12VDC
depends on the type of card
used
Operating
temperature
-10
°
C to +5
0
°
C (
+
14
°
F to
+
122
°
F)
Relative humidity
90% max, operating non-condensing
Reader dimensions
190mm(L) x 1
20
mm(W) x
60
mm(D) (7.
48
”
x
4.
72
”
x
2.
36
”)
Status LED
Green
,
Red, Blue, Orange
Audible tone
Internal and external buzzer control
Keypad (
Bio
XK
o
nly)
3 x 4 Keypad and 4 Function keys, illuminated
Colour finish
Charcoal
IP rating
IP65
BioX
/
Bio
XK
INSTALLATION GUIDE
Rev 002
© 2015 BQT Solutions (Australia) Pty Limited. All rights reserved.
BQT Solutions (Australia) Pty Limited will not be liable for any direct, indirect, incidental or
consequential loss or
damage in any way related to this product. BQT Solutions (Australia)
Pty Limited reserves the right to upgrade or
change this product or instruction manual
without prior notice. BQT Solutions (Australia) Pty Limited assumes no
liability for damages
incurred directly or indirectly from errors, omissions or discrepancies between the product
and the manual.
The product is designed by BQT Solutions (Australia) Pty Limited.
For more information and contact details please visit,
www.bqtsolutions.com
Note:
Fingerprint sensor on BioXK must be activated by pressing 'F1' button.
Sensor will activate for 6 minutes before switching off.
This is only applicable for 'Finger Only' users.