background image

       

1

2

3

Connect  the  bonding  wire  from  the  enclosure  back  plate  to  the 

front piece.

• 

Toothed  lockwashers  to  be  installed  between  housing  and 

ground lugs to ensure electrical contact.

Secure TurboDock wires to the electrical service wires using yellow 

wire-nuts provided, as per electrical code. 
Lift enclosure cover onto notches in back plate. 
Replace #8 screws into holes at bottom sides of the enclosure.

Make your connections

Choose locations on the wall for the cable hangers.  Using a cable 

hanger as a template, mark the holes for the hangers. 

• 

Holes must be at least 6” from the bottom of TurboDock.

• 

Leave enough room between hangers for cables to hang freely.

• 

Attach the cable hangers with installer-supplied #8 fasteners.

INSTALLATION STEPS 

Before you start:

Wall Mount set up

Black (L1)

Green (GND)

Red (L2 or Neutral)

• 

Determine the location and orientation of the wall mounted TurboDock(s), as directed by Account 

Manager (AM). Decide how high the mount must be.**

• 

**Installation must comply with the Americans with Disabilities Act (ADA). The top of each    

TurboDock charger must be between 39” and 49” above the access surface. Access space be-

tween and around the wall-mounts must also comply with the ADA.

• 

Run the appropriate conduit and wiring from the service panel to the installation site per local 

code, #12 AWG minimum.  Use a 20 Amp double-pole circuit breaker for 240V service (Level II 

charging) or a 20 Amp single-pole circuit breaker for 120V service (Level I charging).

Open the wall-mount enclosure. Using the back plate as a template, 

mark hole locations on wall. 

• 

Plumb the back plate with level.

• 

Do not secure back plate to wall yet.

Drill or punch a conduit fitting hole in either the bottom or back 

of  the  mounting  plate,  as  appropriate  for  the  orientation  of  the 

conduit inlet.
Drill holes in the enclosure front piece:

• 

Use  template  included  with  TurboDock  to  mark  the  5  holes 

for each TurboDock on each face of the wall mount enclosure 

where a TurboDock will be installed. 

• 

Note  reference  line  to  be  aligned  with  top  of  wall  mount 

enclosure.

Attach TurboDock chargers to enclosure:

• 

Insert the 3 wires through large hole in the side of the enclosure.

• 

Insert the studs on the charger into the 13/64” holes on the 

enclosure. 

• 

Install and securely tighten the four #10-24 nuts provided.

• 

Repeat for other charger if a dual installation.

Attach the Hanger

Содержание TurboDock

Страница 1: ...ric Code NEC and all local codes In cases of conflict between local codes and the NEC local codes shall take precedence Verify with authority having jurisdiction Model TurboDock NOTICE TO ELECTRICIAN Leave this Installation Guide with the TurboDock AeroVironment EV Solutions TurboDock Charging Station INSTALLATION GUIDE Wall Mounted Installation ...

Страница 2: ...10 24 Hex nuts 10 24 10 Toothed lock washers Wire nuts TurboDock Charge Module Wall mount enclosure cover Ground wire assembly Wall mount back plate 8 32 x long phillips head screws Thread forming screws Cable hanger Black L1 Green GND Red L2 or Neutral ...

Страница 3: ...QUIRED 13 64 drill bit for 10 screw clearance holes 7 8 drill bit or hole saw for wire entry hole Drills as required for and 8 fasteners Drill or knockout punch for conduit fitting used Magnetic torpedo level 1 3 16 2 3 4 13 32 MOUNTING HOLES C L C L BOTTOM OF PEDESTAL REQUIRED HARDWARE NOT SUPPLIED Fasteners and or anchors appropriate for wall material and construction Qty 4 8 fasteners and or an...

Страница 4: ...etween 39 and 49 above the access surface Access space be tween and around the wall mounts must also comply with the ADA Run the appropriate conduit and wiring from the service panel to the installation site per local code 12 AWG minimum Use a 20 Amp double pole circuit breaker for 240V service Level II charging or a 20 Amp single pole circuit breaker for 120V service Level I charging Open the wal...

Страница 5: ...ooting guide Verify that lower front lights show steady blue otherwise refer to the troubleshooting guide On the nameplate label on the front of each TurboDock mark the correct box 240V or 120V Inform the Account Manager that the TurboDock is ready with open access If the AM desires you can now test the TurboDock by charging a vehicle INSTALLATION STEPS ...

Страница 6: ...Specifications are subject to change without notice Images of the Charging Station Model TurboDock are representative production models may vary No portion of these materials may be duplicated used or disclosed without prior written permission from AeroVironment Inc Disclaimer This Installation Guide includes the latest information available at the time of printing AeroVironment Inc reserves the r...