Integrated Alarm Control/Communicator

Year 2000 ready

Express

Installation and Operation Manual

Version 3.06

(with very slow zone)

Edition II

This product is subject to continual enhancement and therefore

specifications may be changed or altered without prior notice

 Item: 4718_2004

www.av-gad.com

Содержание EasyLoader AV-2004

Страница 1: ...tor Year 2000 ready Express Installation and Operation Manual Version 3 06 with very slow zone Edition II This product is subject to continual enhancement and therefore specifications may be changed o...

Страница 2: ...ntrol of output A1 Version 3 02 First alarm indication by DTMF A1 at Latch mode Version 3 04 New at 072 4 activate ON output to drive ADSL filter line disconnect added 999 to exit programming mode dur...

Страница 3: ...ram is set at non EOL for all zones To select EOL mode enter at address 029 the required zone to be EOL or enter 0 to enable all zones as EOL Note Address 029 at the AV 2048 is blocked Only EOL mode i...

Страница 4: ...en using few keypads connect them in parallel Each keypad has four terminal wires Power connect to Aux Power System Data connect to OR Power connect to Aux Power System Strobe connect to YE 7 4 1 0 8...

Страница 5: ...is factory default in Siren mode install only speaker type sirens which DO NOT contain sound driver or electronic modules The alarm issued by the siren differs according to the type of zone Bell Mode...

Страница 6: ...ground properly check that ground does not transfer high voltages 7 BACK UP BATTERY Make sure to connect the Battery in the correct polarity The system s Red wire is the positive pole and the Black w...

Страница 7: ...ORE POWERING UP Place Control Panel in a well ventilated location and as far as possible from any heat source Do not place high power RF wireless transmitters near Control Panel Check for proper groun...

Страница 8: ...n AV 2048 Arming with Group Bypass 2nd Group Bypass added address 034 and the procedure enhanced after selecting the Group Bypass system is armed without code entry To bypass 1st group Press 0 and hol...

Страница 9: ...the function chime mode is not affected by Arm Disarm Chime mode is confirmed by c display on keypad 6 Telephone Key 6 DIALER TEST FOLLOW ME PROGRAMMING Test is performed in Disarmed mode Function Via...

Страница 10: ...isplay Open and close each zone to test A one second beep confirms detection of zone opening Three beeps indicate zone closing Quit Fault Find mode by arming the system 8 Program Key 8 PROGRAM Key 8 a...

Страница 11: ...Mode and exit When last event is displayed and attempting to move forward key 2 a blank sign is displayed and a long warning beep indicating that it is the last event Press key 8 to move backward if n...

Страница 12: ...played zone H For Silent used with Panic button Panic alarm remove siren and buzzer activation by programming the Panic Zone so Panic zone program as 24H zone type N O type fast response type To quit...

Страница 13: ...relay to KE and Aux Power terminals Verify the receiver relay mode momentary or latch and set system accordingly For fast Remote Key wiring the AV 2004 48 M contains a fast insert connection a dedicat...

Страница 14: ...user during alarm When the control panel calls the user during alarm it will first generate the siren sound for about 30 seconds to shorten this feature at address 085 Tel Message Time to 30 as defau...

Страница 15: ...n tune and will hang up 15 USER CODE PROGRAMMING Set New USER CODE 1 Hold down key 8 Program 2 While 4 LEDs are blinking enter code No 1 default 1 2 3 4 3 If code is valid four LEDs will stop blinking...

Страница 16: ...for Automatic Arming By Installer Program or display hours and minutes at address 016 By User Enter to user programming mode Hold down 8 A is displayed type hour and minutes in 24 hours format To dis...

Страница 17: ...oup Bypass II 034 Manual Bypass 035 1 2 3 4 5 6 7 8 Siren Out 036 1 2 3 4 5 6 7 8 Alarm 1 A1 Out 037 1 2 3 4 5 6 7 8 Reserved 038 Reserved 039 Dial on Alarm 040 1 2 3 4 5 6 7 8 Sounder on Alarm 041 1...

Страница 18: ...1 via DTMF 2 Enable 2048 New Zones Wiring Method 2 Enable Auto reset zone after alarm timeout 3 Reserved 4 Enable Zone at 032 Very slow zone 4 Reserved 5 Enable DTMF control D type or Ver 3 6 Enable B...

Страница 19: ...ID or Ademco High Speed 00 No Communicator is identical to Dialer that generates sound upon alarm Contact ID and Ademco H S are available at panels version 2 06 or higher Rnd is shortening for ROUNDS...

Страница 20: ...u can specify to report System Status as default for Extended or 2 digits by programming for example A Armed at 236 and D Disarmed at 254 9 is the test signal code For System Status report select exte...

Страница 21: ...ay Delete 3 If the code is valid P will be displayed The two left LED s Red Green blink to indicate that system is waiting for a new programming address number 4 Enter address to be programmed see pro...

Страница 22: ...value 1 2 3 4 by pressing 1 Siren 2 Shunt Display 3 Status 4 Delay Delete U confirms programming updating 5 P is displayed two left most LEDs are blinking 19 RESET SYSTEM TO DEFAULT PROGRAMMING Warnin...

Страница 23: ...Telephone Line Monitor test address 094 Time interval between telephone line tests in hours Range between 00 24 When 00 programmed no test performed Failure to get a dial tone when dialing will cause...

Страница 24: ...st and simple programming of EasyLoader panels Programming tables codes and other features may be up downloaded from an on site PC DOS Mode via telephone using Modem and EasyLoad software which is sup...

Страница 25: ...ut in text fields by hitting the ENTER return key In order to select the required field hit the highlighted digit or letter Full instructions and latest features are enclosed in the EasyLoad software...

Страница 26: ...re servicing this unit 5 Keypad Connect maximum of two AV 701 or four AV 702 keypads 6 Sirens Connect horn type siren speaker If using Bell adhere to maximum ratings For self contain bells program 3 i...

Страница 27: ...p Resistor 2 200 Ohms 0 25W 5 AV 2048 2 200 and 4 700 Ohms Auxiliary Power Max 13 6V DC 0 5A Combined AUX Power and Keypad outputs Battery Charging Current Max 550 mA current limited Battery Test Indi...

Страница 28: ...ce hereof There is no express or implied warranty of merchantability or a warranty of fitness for particular purpose Additionally this warranty is in lieu of all other obligations or liabilities on th...