background image

4

  

 

Display Segments 

 

1. 

Clock Area—

Displaying the date, time and day of the week 

2. 

Mode  Display—

Showing  your  choice  of  Automatic,  Cooling,  Dry,  Fan 

Only and  Heating Modes 

3. 

Timer  Area—

Displaying the next Timer Occurrence and whether the unit 

will turn On or Off at this time. If this is not displayed then the unit is not 
in Timer Mode 

4. 

Error Code Display Area—

This displays any applicable error conditions 

5. 

Temperature  Display  Area—

This  displays  the  Temperature  as  meas-

ured by the unit 

6. 

Set  Temperature  Display  Area—

This displays the temperature the unit 

is trying to achieve 

7. 

Fan  and  Louver  Display  Area—

This shows the current fan setting and 

whether the swing louver is operational.  

8. 

Output  Device  Display  Area—

This  shows  which  output  devices  are 

operational. These include water pump, reversing valve, outdoor fan mo-
tor, compressor, electric heater and defrost. It also displays whether the 
keyboard lock has been set. 

 







Display Section 

Operation Switch & Status LED 

Located at the top right hand corner of the controller is the Operation Switch and 
a single Display LED. The LED will glow red if the unit is off and green if it is run-
ning. Pressing the operation switch will turn the unit on or off manually. If the 
unit is in timer mode then the timer display section will change when this is done 
to show when this will regain control of the unit. 

ON/OFF 

13  

 

Caring for the Environment 

 

We all have a responsibility to care for the environment and the way 
you  use  your  Highcool  air  conditioner  can  help  by  reducing  energy 
consumption. The following recommendations will all help to keep the 
energy consumed by your Highcool system to a minimum. 
 

• 

Use the time clock to operate your unit only when it is needed. 

• 

If  not  using  the  time  clock  remember  to  switch  the  unit  off 
when a room is unoccupied. 

• 

Choose the  operation mode best suited to the season. Cooling 
mode  in  summer  will  prevent  the  heating  coming  on  while 
Heating  mode  in  winter  will  prevent  unnecessary  cooling.  Use 
automatic  mode  only  during  intermediate  periods  when  both 
heating and cooling are required. 

• 

Set  the  temperature  to  a  realistic  level  and  leave  it  there.  Be-
tween  22  &  24C  is  our  recommendation.  Setting  abnormally 
high or low temperature settings will increase energy consump-
tion  and  may  cause  erroneous  operation.  Making  frequent 
changes  to  the  set  temperature  will  likewise  increase  energy 
consumption with little appreciable difference to comfort. 

• 

Make  sure  the  air  inlet  and  outlet  of  both  indoor  and  outdoor 
units are clean and free from anything that might block the air-
flow. 

• 

Check  &  Clean  the  indoor  unit  air  filters  regularly  as  shown  in 
the Operation and Maintenance Manual. 

• 

If there is another form of heating in the room ensure it is not 
operating  if  the  air  conditioner  is  in  cooling,  dry  or  automatic 
modes. 

• 

If  another  form  of  heating  is  available  in  the  room  but  your 
Highcool system is able to heat the room sufficiently on its own 
then turn the other heating system off. Your Highcool system is 
more efficient that almost  all other  forms  of heating. Only use 
additional heating if the capacity of your unit is not sufficient on 
its own. 

• 

If you lose this manual or require a spare, copies are available 
to download at highcool.co.uk. Reading these on your computer 
rather than printing them will save ink and paper. 

• 

Ensure  you  Highcool  air  conditioner  is  serviced  regularly  by  a 
qualified  and  trained  engineer.  We  recommend  taking  out  a 
service contract with the company that installed it for you in the 
first place. 

Содержание Highcool Series

Страница 1: ...urposes E OE Read the Manual Risk of Electric Shock Unit is Remotely controlled may start without warning WARNING This air conditioner is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their s...

Страница 2: ...perate your Highcool cassette split system in order to get the most from it CONTENTS P2 Introduction P3 General Description P4 Display Section P5 Control Buttons P6 9 Understanding the Display P10 12 Operating the Controller P13 Caring for the Environment P14 Appendix 1 Fault Codes P15 Appendix 2 Engineers Notes P15 Appendix 3 Timer Chart P15 Fault Code Log 15 Appendix 2 Notes for Engineer The con...

Страница 3: ...rip Repair Safety Device Tripped Er05 Critical Low Pressure Switch Trip Repair Safety Device Tripped Er06 Critical High Discharge Temperature Repair Safety Device Tripped Er07 Critical Overcurrent Protection Tripped Repair Safety Device Tripped Er08 Critical Comms Fail Indoor to Outdoor Repair Broken Cable or Interference Er11 Critical Drainage Failure Repair Blocked Drains Er12 Critical Electric ...

Страница 4: ...inimum Use the time clock to operate your unit only when it is needed If not using the time clock remember to switch the unit off when a room is unoccupied Choose the operation mode best suited to the season Cooling mode in summer will prevent the heating coming on while Heating mode in winter will prevent unnecessary cooling Use automatic mode only during intermediate periods when both heating an...

Страница 5: ...ON will allow you to enter Engineer Setup mode Details are available in the Service Manual Parameters in the Engineer Setup mode should only be changed by suitably qualified personnel with a copy of the Service Manual to hand If you enter Engineer Setup mode by mistake press RESET to leave without changing any important system parameters 5 Control Buttons 1 2 3 4 5 6 7 8 9 10 Opening the panel on ...

Страница 6: ... to be used to prevent the room temperature dropping below the set temperature during winter use For your comfort we recommend not setting the temperature above 24C in heating mode 11 What do you want the unit to do Pressing the mode button scrolls between automatic cooling dry fan only and heating modes Choose the mode most appropriate to your needs Automatic will engage whichever mode is necessa...

Страница 7: ... controller to switch the unit on or off 3 If the unit is on then the display LED will glow green If it is off then it will glow red 7 The Timer Area is only lit during timer operation and shows the time when the timer will next turn the unit on or off If the unit is in timer operation and the OPERATION button is pressed then the timer area will advance to the next applicable setting as the OPERAT...

Страница 8: ...s internal controls may over ride the fan speed selected by the user 9 The Output Device Display Area is designed to show which of your sys tems internal components are operating at that moment in time except for the Indoor Fan and Swing Louver which are shown separately in the Fan Louver Display Area It can also display if the keyboard lock is set The Internal Drain Pump is used to remove condens...

Отзывы: