AUX DC Inverter Free Match 50HZ
R32
64
Gas Side
mm(inc
h)
3×9.52(3/8)
3×9.52(3/8)
Max. length for all
rooms (m)
m
60
60
Max. length for
one IU (m)
m
30
30
Max. height
difference
between IU and
OU (m)
m
15
15
Max. height
difference
between IUs (m)
m
10
10
Ambient Temp (Cooling/Heating)
℃
-15~52
℃
/-15~24
℃
-15~52
℃
/-15~24
℃
Stuffing
Quantity
20/40/40H
unit
96/198/198
96/198/198
5.3 36K, 42K
DC INVERTER
Model
AM4-H36/4DR3
AM5-H42/4DR3
System Format
1 drive 4
1 drive 5
Capacity
Cooling
Btu/h
35826(8530~37532) 40944(9451~43332)
kW
10.50(2.5~11.0)
12(2.77~12.7)
Heating
Btu/h
37532(9110~38214) 44356(10100~44800)
kW
11.00(2.67~11.2)
13(2.96~13.1)
Electric Data
Power Supply
V~,Hz,Ph
220~240,50,1
220~240,50,1
Cooling Power
Input
W
3950(680~4930)
4450(750~5450)
Heating Power
Input
W
3150(530~3850)
3750(600~4350)
Rated Current
(cooling&heating) A
17.5/13.96
19.72/16.62
Max current
A
23.5
24.5
Max power
KW
5.3
5.6
Содержание F Series
Страница 1: ...1 Technical Manual DC Inverter Free Match R32 ...
Страница 2: ...2 2019 07 ...
Страница 7: ...7 Part1 General Information 1 Nomenclature Indoor Unit Outdoor Unit ...
Страница 9: ...9 24K Btu h AMWM H24 4R3 J ...
Страница 27: ...AUX DC Inverter Free Match 50HZ R32 27 ...
Страница 30: ...AUX DC Inverter Free Match 50HZ R32 30 Part3 Piping System 1 14K 18K ...
Страница 33: ...AUX DC Inverter Free Match 50HZ R32 33 3 36K ...
Страница 70: ...AUX DC Inverter Free Match 50HZ R32 70 ...
Страница 71: ...AUX DC Inverter Free Match 50HZ R32 71 3 Ceiling Floor 09K 12K 18K 929 660 245 841 205 ...
Страница 74: ...AUX DC Inverter Free Match 50HZ R32 74 5 Outdoor Unit 5 1 14K 18K 545 800 545 822 315 315 ...
Страница 75: ...AUX DC Inverter Free Match 50HZ R32 75 5 2 21K 27K 834 540 655 854 335 328 ...
Страница 76: ...AUX DC Inverter Free Match 50HZ R32 76 5 3 36K 42K 985 675 808 1000 409 395 ...
Страница 80: ...AUX DC Inverter Free Match 50HZ R32 80 ...
Страница 82: ...AUX DC Inverter Free Match 50HZ R32 82 3 Ceiling Floor 09k 12k 18k ...
Страница 83: ...AUX DC Inverter Free Match 50HZ R32 83 4 Duct 07K 09K 12K 18K ...
Страница 92: ...AUX DC Inverter Free Match 50HZ R32 92 Part8 Static pressure curve 1 07K 09K Duct ...
Страница 93: ...AUX DC Inverter Free Match 50HZ R32 93 2 12K Duct ...
Страница 94: ...AUX DC Inverter Free Match 50HZ R32 94 3 18K Duct ...
Страница 103: ...AUX DC Inverter Free Match 50HZ R32 103 XK 04 Detailed operation instructions 6 ...
Страница 143: ...AUX DC Inverter Free Match 50HZ R32 143 1 3 F Type 07K 09K 12K 1 2 3 4 5 6 7 8 9 10 11 12 13 15 16 17 18 19 20 21 14 ...
Страница 145: ...AUX DC Inverter Free Match 50HZ R32 145 1 4 F Type 18K 5 3 2 1 4 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 ...
Страница 147: ...AUX DC Inverter Free Match 50HZ R32 147 1 5 F Type 24K 7 9 20 19 1 2 3 4 5 6 8 10 11 12 13 14 16 17 18 15 ...
Страница 158: ...AUX DC Inverter Free Match 50HZ R32 158 2 Cassette 09K 12K 18K ...
Страница 164: ...AUX DC Inverter Free Match 50HZ R32 164 ...
Страница 166: ...AUX DC Inverter Free Match 50HZ R32 166 4 2 18K ...
Страница 168: ...AUX DC Inverter Free Match 50HZ R32 168 5 Outdoor Unit 5 1 14K 18K ...
Страница 170: ...AUX DC Inverter Free Match 50HZ R32 170 5 2 21K 27K ...
Страница 171: ...AUX DC Inverter Free Match 50HZ R32 171 ...
Страница 173: ...AUX DC Inverter Free Match 50HZ R32 173 5 3 36K ...
Страница 176: ...AUX DC Inverter Free Match 50HZ R32 176 5 4 42K ...
Страница 183: ...AUX DC Inverter Free Match 50HZ R32 183 4 Cassette 4 1 Installation drawing ...
Страница 184: ...AUX DC Inverter Free Match 50HZ R32 184 4 2 The distance between indoor unit and obstacle ...
Страница 189: ...AUX DC Inverter Free Match 50HZ R32 189 ...
Страница 196: ...AUX DC Inverter Free Match 50HZ R32 196 ...
Страница 211: ...AUX DC Inverter Free Match 50HZ R32 211 1 2 21K 27K Main PCB and Driver modular ...
Страница 212: ...AUX DC Inverter Free Match 50HZ R32 212 1 3 36K 42K Main PCB ...
Страница 213: ...AUX DC Inverter Free Match 50HZ R32 213 Drive Modular Board ...
Страница 214: ...AUX DC Inverter Free Match 50HZ R32 214 2 Indoor Unit PCB 2 1 09K 12K 18K Cassette ...
Страница 215: ...AUX DC Inverter Free Match 50HZ R32 215 2 2 09K 12K 18K Ceilling Floor ...
Страница 216: ...AUX DC Inverter Free Match 50HZ R32 216 2 3 07k 09K 12K 18K Duct ...
Страница 219: ...AUX DC Inverter Free Match 50HZ R32 219 2 Failure analysis 2 1 H2 Wired controller communication failure ...
Страница 220: ...AUX DC Inverter Free Match 50HZ R32 220 ...
Страница 221: ...AUX DC Inverter Free Match 50HZ R32 221 2 2 E5 Communication failure between indoor and outdoor unit ...
Страница 222: ...AUX DC Inverter Free Match 50HZ R32 222 Outdoor protection phase sequence ...
Страница 223: ...AUX DC Inverter Free Match 50HZ R32 223 2 3 P2 high pressure protection Cooling high pressure protection ...
Страница 224: ...AUX DC Inverter Free Match 50HZ R32 224 Heating high pressure protection ...
Страница 225: ...AUX DC Inverter Free Match 50HZ R32 225 2 4 H6 low pressure protection ...
Страница 226: ...AUX DC Inverter Free Match 50HZ R32 226 Cooling low pressure protection ...
Страница 227: ...AUX DC Inverter Free Match 50HZ R32 227 Heating low pressure protection ...
Страница 228: ...AUX DC Inverter Free Match 50HZ R32 228 ...
Страница 230: ...AUX DC Inverter Free Match 50HZ R32 230 Heating exhaust temperature protection ...
Страница 231: ...AUX DC Inverter Free Match 50HZ R32 231 ...
Страница 232: ...AUX DC Inverter Free Match 50HZ R32 232 2 6 H8 four way valve failure protection ...
Страница 233: ...AUX DC Inverter Free Match 50HZ R32 233 ...
Страница 234: ...AUX DC Inverter Free Match 50HZ R32 234 2 7 Sensor failure protection ...