14.2.1
YGDAI Mode
The YGDAI mode is set by default to “16 Channels” mode.
The “16 channels” mode is compatible with new generation of YGDAI Slot and must be
used for PM5D, DM2000, DM1000, 02R96, DME64N, DME24N and 01V96 Yamaha
devices.
The “8 channels” mode is compatible with previous version of YGDAI Slot and must be
used for the following Yamaha devices: DIO8/PM1D, DME32, AD824, DA824, 01V.
Warning: If you put an AVY16-ES with “16 channels” mode set in an “8 channels” only
mini-YGDAI slot device, the AVY16-ES will be not recognised by the device and you could
have unknown behaviour in the device. It is strongly recommend muting first all outputs
before installing the AVY16-ES for the first time. Even if the AVY16-ES is not recognised
by the host device, you can manage and then program it with ESMonitor. First action in
such device is to set the AVY16-ES in ““8 channels” mode and then reset the device.
14.2.2
“Lock Routing” function
“Lock Routing” is disabled by default.
The “lock routing” function allows to disable remote software modification of EtherSound
routing for the board. This is useful to prevent wrong patching during live event.
When the lock routing is set the “Hardware configuration Flag” of the property page is set
to “ON” which simulates an EtherSound hardware setting (routing done only by hardware
dip switch).
When the lock routing is disabled the “Hardware configuration Flag” of the property page
is set to “OFF” which enables software routing
14.2.3
“Emergency Clock” function
“Emergency Clock” is disabled by default.
The “Emergency Clock” function enables to generate automatically a local 48 kHz Clock
from the AVY16-ES to its host digital console when the board is disconnected from an
EtherSound network from its EtherSound IN port. This mode enables to not let the digital
console to go in long time free run before it recovers its clock after a network
disconnection which usually mutes all audio I/O.
This mode must be used only if the digital console is synchronised from the
AVY16-ES board in other case this will generate a Clock conflict in the console.