![AuviTran Audio ToolBox AVBx3 Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/auvitran/audio-toolbox-avbx3/audio-toolbox-avbx3_instruction-manual_3023588010.webp)
AuviTran Audio ToolBox Instructions Manual
10
6
GPI/O Interface
Each connection on GPI/O must be Safety Extra Low Voltage kind (SELV).
The Audio ToolBox contains 4 GPI/O (General Purpose Input/Output) configurable as GPI or GPO. GPI/O are available on a
1x6 poles Euroblock connector close to the Power Inlet Connector.
Each GPIO can be configured as GPI or GPO individually, with AVS-Monitor software. Configuration and use is described
later in this document.
GPO
can supported 60Vdc max / 500mA max
GPO
Command
ON/OFF
GPO
OUT
GPI
The user can select between 2 modes (Max Voltage Supported 60 Vdc)
ADC Input (8 bits scale)
Range 0-12V (12V = ADC Full Scale)
Trigger Detection
TTL Level
(logic “1” = GPI > 2V)
OFF State
Output state = Open collector
60 Vdc max
ON
State
Output state = 0 V (GND)
500mA max