Autotrol 255-460i Скачать руководство пользователя страница 18

18

Preventive Maintenance

Inspect and clean brine tank and screen filter on end of 
brine pickup tube once a year or when sediment 
appears in the bottom of the brine tank.

Injector Screen and Injector

The injector is the component which creates the 
vacuum necessary to draw the brine into the water 
conditioner. Clean the injector and injector screen once 
a year in order to maintain proper water conditioning. 
Some locations may require more frequent injector and 
screen servicing. Refer to Figure 19 and complete the 
following steps to clean the injector screen and injector.

1. Unplug the wall mount transformer.

2. Shut off water supply or put bypass valve(s) into 

bypass position and remove the rear cover.

3. Relieve system pressure by opening valve 

number 6 (at rear) with a screwdriver (Figure 15).

4. Using a screwdriver, unscrew and remove the 

injector screen and the injector cap.

5. Clean screen with a fine brush. Flush with water 

until clean.

6. Using a needle-nose pliers, pull the injector straight 

out. 

7. Squirt water into the injector screen recess of the 

valve body to flush debris out.

8. Clean and flush injector.

9. Lubricate the O-rings on the injector, injector cap, 

and injector screen with silicone lubricant and 
reinstall.

Important: Do not overtighten the plastic cap. Seat the 
cap lightly into position. Overtightening may cause 
breakage of the plastic cap that may not be 
immediately evident.

10. Reinstall cover, reconnect electric power, and reset 

the time of day.

11. Slowly open the water supply valve or return the 

bypass valve(s) to the “not in bypass” position.

Figure 19

Water Meter

In rare instances, the turbine wheel of the water meter 
may collect small particles of oxidized iron, eventually 
preventing the wheel from turning. The turbine wheel 
may be serviced as follows (Figure 20):

1. Shut off the water supply or put bypass valve(s) into 

bypass position.

2. Relieve system pressure by opening valve 

number 6 (at rear) with a screwdriver (Figure 15).

3. Loosen and remove the fasteners that hold the 

meter adapter to the tank adapter and the 
fasteners that hold the piping boss or bypass valve 
to the meter adapter.

4. Remove the meter adapter, being careful not to 

misplace any of the O-rings.

5. Using a needle-nose pliers, grasp one of the four 

vanes of the gland and, pulling straight out, remove 
the gland from the adapter.

6. Carefully remove the turbine wheel from the 

housing. Using a toothbrush, lightly scrub the iron 
off the magnet. Iron buildup on the wheel surfaces 
may be removed by soaking the wheel in a mild 
sodium hydrosulfite (e.g., RoVer*) solution for a few 
minutes, then flushing thoroughly with water.

7. Carefully reinstall the turbine wheel into the 

adapter, being certain that the shaft of the wheel 
seats into the bearing of the adapter and that the 
“dimple” on the wheel faces you.

8. Carefully reinstall the gland into the adapter, being 

certain that the shaft of the wheel seats into the 
bearing of the gland; press the gland all the way in, 
being sure the wheel rotates freely.

9. Reinstall the meter adapter, O-rings, piping boss, 

or bypass valve, tighten all fasteners and re-
establish the water supply to the system.

10. Check for proper water meter operation by opening 

a downstream faucet and observing the water flow 
indicator light on the 460i display.

*RoVer is a trademark of Hach Chemical Company.

Figure 20

Screen

Brine Control

Injector

Содержание 255-460i

Страница 1: ...Water Conditioning Control System Installation Operation and Maintenance Manual Series 255 Valve 460i...

Страница 2: ...mshaft 460i timer utilizes a microprocessor to provide a time proven logic analysis to initiate regeneration Electrical wiring is factory assembled System cannot be connected incorrectly System indexe...

Страница 3: ...n the calculated reserve Self Adjusting Reserve The 460i is programmed to react to a sudden increase in water usage If a day s usage is more than double the current average the computer anticipates th...

Страница 4: ...rd L Lid Cover Brine Line Fitting Connection 1 4 inch NPT Air Check Tank Thread 2 1 2 inch 8 Male Inlet Connection 3 4 inch or Drain Connection 3 8 inch or Outlet Connection 3 4 inch or 1 inch NPT or...

Страница 5: ...F 1o C or over 120o F 49o C 6 Do not install unit near acid or acid fumes Water Line Connection A bypass valve system must be installed since there will be occasions when the water conditioner must b...

Страница 6: ...ct the plug of the transformer secondary cable to the mating socket on the bottom of the controller Be certain the transformer is plugged into a source that is not controlled by a wall switch and cann...

Страница 7: ...CLOCKWISE until arrow points to the center of the BRINE SLOW RINSE position D With the conditioner in this position check to see if water is being drawn from the brine tank The water level in the brin...

Страница 8: ...dicating zero days of calendar override All 460i controllers are preprogrammed in this manner at the manufacturer 4 Depress the black TIME SET button The numbers will roll from 0 to 15 Release the swi...

Страница 9: ...the amount required for the next regeneration Refer to the Suggested Salt Dial Settings Table Table 1 for proper salt settings To set the salt dial insert a screwdriver into the slot Figure 13 and mov...

Страница 10: ...valve number 6 at rear Figure15 Figure 14 Figure 15 4 Remove screw in locking bar Figure 16 Figure 16 5 Apply downward hand pressure on control and pull locking bar out Figure17 Figure 17 6 Using a ro...

Страница 11: ...BSPT drain 1 inch BSPT inlet outlet 1 2 inch BSPT drain Optional Bypass Valve 3 4 inch 19 1 mm or 1 inch 25 4 mm copper tailpiece 1 2 inch NPT male drain Control Module Tank Adapter Optional Bypass V...

Страница 12: ...ressure Graphs Control Valving Identifications Valve Disc Operation Flow Diagrams 1 Conditioned Water Position bar bar bar Use with 8 or Larger Backwash Control Use with 10 or Larger Backwash Control...

Страница 13: ...13 2 Backwash Position 4 Slow Rinse Position 3 Brining Position 5 Brine Refill and Purge Position...

Страница 14: ...14 Replacement Parts Valve Body and Tank Adapter Module 3 22 20 6 15 14 2 18 16 8 9 19 5 7 7 1 23 23 23 24 24 24 11 25 17 10 12 13 21 4...

Страница 15: ...all Flow Control 1 8 Injector Assembly with O Rings 1 1032970 A Injector White 1032971 B Injector Blue 1032972 C Injector Red Code Part No Description Qty 9 Injector Cap with O Ring 1 1000217 A Cap 10...

Страница 16: ...Boss Note Do not use pipe joint compound when threading pipe into the Noryl piping boss Use only Teflon pipe tape Do not overtighten pipe into Noryl piping boss Teflon is a registered trademark of E...

Страница 17: ...mm CPVC Tube Adapter Kit 1001769 3 4 inch NPT Plastic Pipe Adapter Kit 1001603 1 inch NPT Plastic Pipe Adapter Kit 1001604 3 4 inch BSPT Plastic Pipe Adapter Kit 1001605 1 inch BSPT Plastic Pipe Adapt...

Страница 18: ...9 Water Meter In rare instances the turbine wheel of the water meter may collect small particles of oxidized iron eventually preventing the wheel from turning The turbine wheel may be serviced as foll...

Страница 19: ...lay shows something other than time of day a Electrical interference b Defective circuit board a Disconnect power to unit Restore power and reset time of day display b Replace timer 5 No water flow di...

Страница 20: ...mming section f Remove meter housing free up turbine and flush with clean water Turbine should spin freely if not replace meter g Repair leaky plumbing and or fixtures 12 Control will not draw brine a...

Страница 21: ...lugged injector d Air check valve closed prematurely a Check for power b Add salt to brine tank c Remove injector and flush it and injector screen d Put control momentarily into refill to free air che...

Страница 22: ...22...

Страница 23: ...23...

Страница 24: ...Copyright 1999 Osmonics Inc Printed in the USA P N 1017947 Rev B...

Отзывы: