Autostart AS-1565 Скачать руководство пользователя страница 2

TURBO MODE (OFF by default) 
 

When this option is programmed, the unit will always keep the vehicle running 
for 60 sec after arming and locking the vehicle to complete ready-mode.  

 

NOTE: 

The vehicle can be shut off by remote within the 60sec, if turbo idle 

down is not required. 

 

To activate TURBO MODE you must do the following: 

1.  With vehicle running and the doors closed, press LOCK UNLOCK or 

START button on the transmitter until the Parking lights flash 3 times 
then come on solid. 

2.  Remove the key and exit the vehicle. 
3.  Lock doors - Vehicle will stay running for 60sec. 
 
 

VALET MODE 

 
The system can be placed in Valet Mode to disable the remote starting 
capabilities. If the vehicle needs to be serviced, or if you park it indoors, there 
is no danger of accidentally starting the engine by remote control. 
 
To put the system into Valet Mode, turn the key to the ignition ON position, 
and press and hold the Valet switch for approx. 3 seconds. The LED will turn 
ON, letting you know that it is now in Valet Mode. 
 
To take the system out of Valet Mode, turn the key to the ignition ON 
position, and press and hold the Valet Switch for 3 seconds. The LED will turn 
OFF, letting you know that it is now out of Valet Mode. 
 

COLD WEATHER MODE 

 
Your Autostart can be set in Cold Weather Mode. When programmed, it will 
start and run your engine every 2 hours for 4-minute intervals (gas engines) or 
20-minute intervals (diesel engines), during a period of 24 hours. 
 
To program Cold Weather Mode, press and hold the 

STOP

 button for approx. 

5 seconds until the parking lights flash 3 times. 
To exit Cold Weather Mode, do any of the following: 

• 

Open the hood 

• 

Start the vehicle by remote 

• 

Turn the ignition ON 

• 

Press and hold the 

STOP

 button for approximately 5 seconds. 

NOTE

: By pressing the brake, parking lights will flash once to let you know 

that your are in Cold Weather Mode. You must program Cold Weather Mode 
each time you want to use it. 

PARKING LIGHT DIAGNOSTIC 
 
 
 

FLASHES RATE 

DESCRIPTION 

2 Slow 

System power up 

 

 

Quick 

1-  Doors locked by remote 
2-  Cancellation of cold weather mode 

        3- System shut down after expiration of    
run time 

 

 

Quick 

Doors unlocked by remote 

 

Quick 

System is placed into cold weather mode 

 

Quick 

12-volts is detected on brake line while 
running by remote 

 

Quick 

1-  New transmitter code learn 

        2- Confirmation of tach learn 

 

 

Quick 

Confirmation of module being reset 

10 

 

Quick 

Ground detected on hood-switch line while 
remote started or running by remote 

ON 

 

20 sec. 

Hood switch was pressed 2 times within 4 
seconds 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

7