8
6 Settings
6.1 The sensor is to switch when the object is detected
1
►
Position the object
►
Press [OUT on] for 2 s.
> The sensitivity is set to the object.
> The LED flashes.
2
►
Remove the object
►
Press [OUT off].
> The sensitivity is set without object.
> The LED goes out. The programming is finished.
6.2 The sensor is not to switch when the object is detected
►
Position the object (see figure 1) and press [OUT off] for 2 s.
►
Remove the object (see figure 2) and press [OUT on].
The setting can also be carried out first without object and then with object.
6.3 Setting of the maximum sensitivity
►
Align the sensor so that no light is reflected.
The sensor is to switch when the object is detected
►
First press [OUT on], then [OUT off].
The sensor is to switch when the object is not detected
►
First press [OUT off], then [OUT on].