5
If entered digit is not correct, press and release “Read/OK” button until the module
indicates an error. Enter the code once more in that case. Several codes can be
entered without exit of setup mode.
Turn the ignition off to exit from the Setup mode. New settings are saved in the
non-volatile memory of the module and stored there regardless of whether the
module is connected or not.
Note:
start the engine inside the Setup mode if you
want to exit without saving of new settings.
To reset the module to factory settings, enter the code 8.1.1. Both direction
indicators in the CIP should flash three times, confirming command execution.
Then the module exits Setup mode and restarts.
Settings table (1)
Settings
Group
Settings
Item
Possible Values
1.
Heater’s
operation
time
1.1.
Limitation of
heater total
operational time in
pre-heat mode
1.1.1
*Not adjusted
1.1.2
40 minutes
1.1.3
50 minutes
1.1.4
60 minutes
1.1.5
70 minutes
1.1.6
80 minutes
1.1.7
90 minutes
1.1.8
100 minutes
1.1.9
120 minutes
1.2.
Limitation of
heater 1-cycle
operational time in
pre-heat mode
1.2.1
10 minutes
1.2.2
15 minutes
1.2.3
20 minutes
1.2.4
25 minutes
1.2.5
30 minutes
1.2.6
40 minutes
1.2.7
50 minutes
1.2.8
60 minutes
1.2.9 *
Not adjusted
2.
Heater
control with
remote
control key
2.1.
“Lock” and
“Lamp” buttons
functions for heater
control
2.1.1
*”Lock” button for the heater start,
“Lamp” button for the heater stop
2.1.2
“Lamp” button for the heater start,
“Lock” button for the heater stop
2.2.
Number of
sequential “Lamp”
button presses for
heater control
2.2.1
Two presses
2.2.2 *
Four presses
2.2.3
Six presses
2.2.4
Combination is disabled
2.3.
Number of
sequential “Lock”
button presses for
heater control
(when perimeter
lighting is on)
2.3.1
One press
2.3.2 *
Two presses
2.3.3
Three presses
2.3.4
Combination is disabled