Autoplugin Key-V3 Скачать руководство пользователя страница 5

5

If entered digit is not correct, press and release “Read/OK” button until the module 
indicates an error. Enter the code once more in that case. Several codes can be 
entered without exit of setup mode. 
Turn the ignition off to exit from the Setup mode. New settings are saved in the 
non-volatile memory of the module and stored there regardless of whether the 
module is connected or not. 

Note:

start the engine inside the Setup mode if you 

want to exit without saving of new settings. 
To reset the module to factory settings, enter the code 8.1.1. Both direction 
indicators in the CIP should flash three times, confirming command execution. 
Then the module exits Setup mode and restarts. 

Settings table (1)

Settings 
Group

Settings 
Item

Possible Values

1.

Heater’s
operation 
time

1.1. 

Limitation of 

heater total 
operational time in 
pre-heat mode

1.1.1

*Not adjusted

1.1.2

40 minutes

1.1.3

50 minutes

1.1.4

60 minutes

1.1.5

70 minutes

1.1.6

80 minutes

1.1.7

90 minutes

1.1.8

100 minutes

1.1.9

120 minutes

1.2.

Limitation of 

heater 1-cycle 
operational time in 
pre-heat mode 

1.2.1  

10 minutes

1.2.2  

15 minutes

1.2.3  

20 minutes

1.2.4  

25 minutes

1.2.5  

30 minutes

1.2.6  

40 minutes

1.2.7  

50 minutes

1.2.8  

60 minutes

1.2.9  *

Not adjusted

2.

Heater 
control with
remote 
control key

2.1. 

“Lock” and 

“Lamp” buttons
functions for heater 
control

2.1.1

*”Lock” button for the heater start, 

“Lamp” button for the heater stop  

2.1.2

“Lamp” button for the heater start, 

“Lock” button for the heater stop

2.2.

Number of 

sequential “Lamp” 
button presses for 
heater control

2.2.1  

Two presses

2.2.2  *

Four presses

2.2.3  

Six presses

2.2.4  

Combination is disabled 

2.3.

Number of 

sequential “Lock” 
button presses for 
heater control 
(when perimeter
lighting is on)

2.3.1  

One press

2.3.2  *

Two presses

2.3.3  

Three presses

2.3.4

Combination is disabled 

Содержание Key-V3

Страница 1: ...Autoplugin Key V3 Version 9 6 User Manual Rev B...

Страница 2: ...ssibilities 3 Package Content 3 Connection 3 Basic Functions 4 Additional Functions 4 Troubleshooting 7 Glossary CAN Control Area Network digital network for data transfer in vehicles CIP Combined Ins...

Страница 3: ...ditional main battery protection from discharging by inspecting of voltage level and time of heater autonomous operation Package Content 1 Autoplugin Key V3 cartridge 2 User Manual brochure Connection...

Страница 4: ...ter Setup mode and to change the settings It is necessary to stop the engine and the heater before Switch the ignition on turn the key to the position II then press and hold the brakes pedal Rotate th...

Страница 5: ...r total operational time in pre heat mode 1 1 1 Not adjusted 1 1 2 40 minutes 1 1 3 50 minutes 1 1 4 60 minutes 1 1 5 70 minutes 1 1 6 80 minutes 1 1 7 90 minutes 1 1 8 100 minutes 1 1 9 120 minutes 1...

Страница 6: ...dicators in rearview mirrors 6 1 Indication of heater startup 6 1 1 Off 6 1 2 Five flashes 6 2 Indication of command reception from a remote control 6 2 1 Off 6 2 2 Three flashes 6 3 Indication of hea...

Страница 7: ...It is heater manufacturer restriction Fuel level in the fuel tank is close to empty Fuel Low warning indicator is illuminated in the CIP Refuel the car The heater is blocked after several unsuccessful...

Страница 8: ...ed in module s memory incorrectly Reset the settings 8 1 1 readjust the module 11 Heater no connection The heater is unplugged or out of order Make diagnostics of the heater The device is powered from...