SECTION 9 - TROUBLESHOOTING
9.1 Troubleshooting
No Cell X
The unit has not detected a power module in that position.
Typical Solution
Confirm all connections are secure.
Problem
A ribbon connector may need to be replaced.
Typical Solution
Switch the ribbon connector with another power module to verify.
Problem
A power module may need to be replaced.
Typical Solution
Switch the ribbon connector with another power module to verify.
Cell X Not Found
The unit has detected that a power module is connected to that cell position but a signal is not
being sent past the power module connection.
Typical Solution
Confirm all connections are secure.
Problem
The cell cord may need to be replaced.
Typical Solution
Switch cell cord with another cell to verify.
Problem
The cell may need to be replaced.
Typical Solution
Switch with another cell to verify.
Problem
A ribbon connector may need to be replaced.
Typical Solution
Switch the ribbon connector with another power module to verify.
Problem
A power module may need to be replaced.
Typical Solution
Switch the ribbon connector with another power module to verify.