2.7 POWER SUPPLY INSTALLATION
WARNING:
Failure to heed the following may result in injury or death.
•
RISK OF ELECTRICAL SHOCK - All electrical connections should be made by a
licensed electrician or certified electrical contractor.
•
RISK OF ELECTRICAL SHOCK - Ensure electrical power is disconnected before
wiring the unit. Follow all state / local NEC (CEC if applicable) electrical codes. Use
copper conductors, only.
•
RISK OF ELECTRICAL SHOCK - The AutoPilot
®
PRO WC system must be mounted
a minimum of 5 ft. (1.5 m) from the pool.
CAUTION:
Failure to heed the following may result in personal injury or equipment
damage.
•
Due to the weight of the Control Center, it is recommended to have another person
assist you when mounting to the wall.
•
Never try to support the weight of the power supply or electrolytic cell using only
drywall anchors.
Locate a suitable space on the wall, in the equipment room, that will accommodate the
dimensions of the system. The power supply brackets should be mounted to a solid wall
surface or wall stud. Failure to mount the power supply properly may result in the dislodging of
the unit, which can cause serious injury. Make certain there is a clear area in front of the power
supply so that the front access door can swing open completely. The cell assembly must be
mounted no more than 8’ (2.4 m) away from the power supply to ensure that the cables will
reach the cell.
2.8 ELECTROLYTIC CELL INSTALLATION
WARNING:
Failure to heed the following may result in injury or death.
•
The mounting location of the electrolytic cell must be at least 5 ft
.
(1.5 m) from the pool.
Install the cell mounting bracket to the wall using appropriate hardware. Ensure that the wall
mount is level. Mount the electrolytic cell and tube to the mounting backboard. The cell and
tube should be mounted within 8 ft. (2.4 m) of the power supply. In order to allow for easy
service and maintenance, do not install any other equipment less than 30 in (77 cm) above the
cell tube. The cell anode assembly may need to be removed for service.