Page 5 APCG4
Start Up Procedure
After completing the installation, follow this start up procedure.
Verify the power switch is off and the unit is not plugged in.
Verify there are no foreign objects or loose packing materials
on the inside of the unit.
Make sure nothing appears damaged or out of place.
Check and confirm that the gas connections are connected
properly.
Pressurize the gas lines by opening any of the shut off valves
on the gas supply. Test for gas leaks especially if this is the
first time the unit will be used,
Make sure there are no objects within 20” of the surface of the
unit.
Plug in the 24 volt DC power supply into a 120 volt power
source. Then connect the small power cable to the power inlet
jack on the CO2 generator.
Turn the power switch ON. The green LED indicator light
should illuminate next to “Main Power On”.
Shortly after, the ignition module will attempt to ignite the
burner(s) for approximately 5 seconds. The yellow LED
indicator light should illuminate next to “Pilot Valve On”
If the burners fire, continue to next step. If this is the first time
using this unit or the LP tank has been replaced recently, the
burners may not fire the first attempt. After a 30 second pause,
it will attempt to re-fire the burner(s) for 15 seconds. This cycle
will repeat until it fires or for a maximum of 5 tries.