1. Overview

This is an auxiliary instrument for installations, testing and maintenance of 

refrigeration equip-ment such as air conditioners and cold storage. It comes with 

three main functions with digital readings and multi-unit switching. Build-in 89 

refrigeration database drives it provide much more accurate readings.

High-strength engineering plastic and flexible non-slip silicone make instrument solid 

and comfortable to hold.

Build-in 32-bit digital processing unit and high precision data acquisition unit make 

instrument efficient and stable.

Large size LCD display and backlight support test reading clear and operation in dark 

condition.

Heavy duty valve switch and 1/4 inch inlets ensure instrument durable and versatile.

Build- in 89 types of refrigeration database eases user check condensation 

temperature and evapor-ation temperature intelligently.

Vacuum Test and Pressure Leak Test with leak time recording perfectly match users’ 

needs of pressure test and measurement in the process of filling refri-gerant.

2. Safety Rules and Precautions

This manual includes instructions and precautions for operation and maintenance. 

Failure to use the instrument in accordance with this manual could cause damage to 

instrument. Design and produc-

-tion strictly follow IEC/EN61010-1 safety standard.

  1) The pressure measured by instrument is gauge pressure.
  2) Pressure testing ranges from -101Kpa to 6Mpa (-0.1bar to 60bar).
  3) Limit pressure is 10Mpa(100bar).
  4) Maximum operation pressure of standard hose is 600 PSI(approximate 4.13Mpa, 

41.3bar). The limit pressure is 3000PSI ( approximate 20.68Mpa, 206.8bar).
  5) Please confirm the rated pressure value of the tested equipment before testing. 

Do not use it if it exceeds the range of the instrument. If the packed hose does not 

match the pressure requirement, other suitable replacements are available for test.
  6) Do not use or store the instrument in fields with high temperature, high humidity, 

flammable, explosive or strong electromagnetic.
7) Do not revise internal circuit of the instrument to avoid any damage to it or danger 

occurring.
  8) Please wear qualified protective equipment during testing.
  9) Please use the instrument in a well-ventilated environment to prevent inhaling 

toxic gases.

2

Содержание LM110

Страница 1: ...Digital Manifold Gauge User Manual www autooltech com AUTOOL LM110...

Страница 2: ...conditions Formal statement The other product names mentioned in this manual are used to explain how to use this device and the registered trademark still belongs to the original mark owner This equip...

Страница 3: ...i gerant 2 Safety Rules and Precautions This manual includes instructions and precautions for operation and maintenance Failure to use the instrument in accordance with this manual could cause damage...

Страница 4: ...NIST According to American NIST Standard Warning High Voltage Electric Shock Earth Double Insulation Fuse Battery DC DC AC R11 R113 R114 R115 R116 R12 R123 R124 R125 R1270 R13 R134A R14 R141B R142B R...

Страница 5: ...ge Direction of Refrigerant Selection long press Parameter Increment short press 6 Refrigerant Observation Window 7 Valve 8 1 4inch Pressure Inlet 9 Refrigerant Inlet Vacuum Pump Inlet 6 FUNCTION INST...

Страница 6: ...temperature 7 Turn off valve after filling completed Rapidly remove connection between instrument and refrigeration system and refrigerant source 8 Turn off the instrument NOTE Filling operation of di...

Страница 7: ...s used for inspecting how much does pressure change in some time after refrigeration system has been filled with some refrigerant or vacuumed 1 Instrument should be turned on with valve turned off 2 P...

Страница 8: ...records original pressure and test period Press ARROW button could switch display to see difference value of pressure original pressure and test time duration respectively 5 Press SETTING button again...

Страница 9: ...efrigerant Filling There is a valve core in the refrigerant inlet of the system When connecting instrument to system pay attention to the two terminals of the hose Connect one terminal with a core to...

Страница 10: ...alue is absolute vacuum as a starting point the symbol is PABS ABS is a subscript and the absolute pressure is atmospheric pressure gauge pressure At atmospheric pressure the gauge pressure is 0 and t...

Страница 11: ...eo and pictures of the product that fails within 90days after receipt If the product has been received for more than 90 days we will provide the spare parts for replacement without charge but the buye...

Страница 12: ......

Отзывы: