Installation

Store the unit upright. If the unit has been stored or transported on its back, front 
or sides then it must be placed upright for at least an hour before switching on. 
Place the unit on an even floor as far away as possible from any source of heat.

Note: 

Do not move unit by lifting either the door or door handle as this may 

cause damage to the cabinet.

Please ensure the correct aperture size is made available for this unit:

02

 

Space Required 

All dimensions exclude door handle  

 

 

Height 

Width 

Depth 

Single Unit 

925mm 

530mm 

525mm 

 

Unit Dimensions 

All dimensions exclude door handle  

 

 

Height 

Width 

Depth

 

Single Unit 

900mm 

525mm 

500mm 

 

The correct aperture size should 
give a gap of approximately 25mm 
between the top of the cabinet and 
the underside of the back bar and 
between the back of the unit and 
the wall. Poor ventilation due to 
insufficient aperture size is likely to 
cause: reduced cooling; Icing up; 
Premature compressor failure.

General Operation

The cabinet door should remain firmly closed during normal operation. This 
prevents warm moist air entering and creating frost within the cabinet. If the 
cabinet is left open for extended periods ice will form. This will prevent cooling 
and the machine will then require defrosting (see page 03).

The unit should be left switched on, and should not be switched off between 
trading sessions. The unit is designed to operate in an ambient temperature 
range of 6°C -25°C, however for short periods of time (up to 8 hours) the unit 
will operate normally at 32°C. The cabinet is designed to chill product in sealed 
containers only i.e. bottles, cans etc. It is not recommended that glasses of 
drink or similar are placed in the unit for cooling.

Содержание WRCBS600

Страница 1: ...ocument JF000135 Issue 4 Popular Premier Cooler Single Integral Unit User Installation Guide This guide contains instructions for Autonumis Single door model Back bar bottle coolers Serial Number Mode...

Страница 2: ...l Operation 02 Controls 03 Routine Maintenance 04 Repairs 04 End of Life Disposal 04 Spares Order 05 Spares Identification 06 Wiring Diagram Popular Premier 07 Wiring Diagram Popular Premier Ecochill...

Страница 3: ...e underside of the back bar and between the back of the unit and the wall Poor ventilation due to insufficient aperture size is likely to cause reduced cooling Icing up Premature compressor failure Ge...

Страница 4: ...efrigeration is switched on and off at the mains supply The light is controlled independently by using the toggle switch provided at the front of the unit Warning If the supply cord is damaged the man...

Страница 5: ...f at the mains before attempting the following maintenance and repair procedures Lamp Replacement Open the front door and remove the lamp cover This is achieved by slightly compressing the cover and l...

Страница 6: ...gram below These parts will be made available for a period not less than five years after a machine has ceased to be produced or a change has been introduced Where a change of part results in a lack o...

Страница 7: ...06 16 13 8 7 2 4 12 1 6 3 10 5 14 9 11 Blanking Plugs Left Hand Hinge Point Standard Hinge Point Top Hinge Plate 15 Not all Models...

Страница 8: ...rawing Not to scale Wires drawn green are green with yellow tracer Wires drawn grey are actually white Green Yellow Blue Blue Blue Red Red Brown Brown Brown Brown Yellow Yellow Yellow Yellow Orange Bl...

Страница 9: ...es drawn green are green with yellow tracer Wires drawn grey are actually white Blue Blue Red Brown Brown Brown Brown Yellow Yellow Yellow Yellow Orange Black Black Orange Yellow Yellow White White Th...

Страница 10: ...09 Notes...

Страница 11: ...10 Notes...

Страница 12: ...Autonumis Ltd Cirencester Rd Tetbury Gloucestershire GL8 8SA United Kingdom Tel 44 0 1666 502641 Fax 44 0 1666 504397 www autonumis com...

Страница 13: ......

Отзывы: