background image

18, Bansong-ro 513Beon-gil, Haeundae-gu, Busan, Republic of Korea, 48002

www.autonics.com  |  +82-51-519-3232  |  [email protected]

-|Transparent Guide|-

Initial Display When Power is ON

When power is supplied, series and model name are flashed twice sequentially (for 1 
sec), and enter into RUN mode.

1. Input secification 2. Control output 3. RUN mode

Temperature 

display part

   JIC

   RLY

   250

Mode Setting

RUN

[MD]

SV setting

Change value: [▼], [▲]

With save:  [MD]

Without save:  no key input 

over 60 sec

RUN

[MD] 2 sec

→ Parameter 1 group

[MD] over 3 sec

[MD] 4 sec

→ Parameter 2 group

Parameter Setting

• Some parameters are activated/deactivated depending on the model or setting of 

other parameters. Refer to the descriptions of each item.

• [MD] key: Move to next item after saving / Return to upper level with save (≥ 3 sec)

 

[▲] key: Select parameter

 

[▲], [▼] key: Change setting value 

• If there is no key input over 1 min, return to the RUN mode without saving.

  

■ Parameter 1 group

Parameter

Display

Default

Setting range

Condition

1-1 Proportional 

band

P

0

0 (ON/OFF control) ~ 100%

-

1-2 Proportional 

control cycle

T

10

1 ~ 120 sec

1-1 Proportional 

band: > 0

1-3

Offset 

correction for 

proportional 

control

RST

50

0 ~ 100%

-

1-4 ON/OFF control 

hysteresis

HYS

2

1 ~ 100 ℃

1-1 Proportional 

band: = 0

1-5 Input correction

InB

0

-30 ~ 30 ℃

1-1 Proportional 

band: > 0

Parameter

Display

Default

Setting range

Condition

2-1 Input 

specification

Int

JIC

Refer to 'Input Type and Using 

Range: Input specification'.

-

2-2 SV high limit

hSC

400

Refer to 'Input Type and Using 

Range: Using range'.

-

2-3 SV low limit

lSC

0

2-4 Control output 

mode

oFT

HET

HET: Heating, COL: Cooling

-

2-5 Error, output

oER

OFF

ON, OFF

-

2-6 Temperature 

unit

UNT

?C

℃, ℉

-

2-7 Lock

LOC

OFF

OFF

LOC1: Lock parameter 2 group

LOC2: Lock parameter 1/2 group

LOC3:  Lock parameter 1/2 group, 

SV setting

-

  

■ Parameter 2 group

Segment Table

The segments displayed on the product indicate the following meanings. It may differ 
depending on the product.

7 segment

11 segment

12 segment

16 segment

0

0

I

I

0

0

I

I

0

0

I

I

0

0

I

I

1

1

J

J

1

1

J

J

1

1

J

J

1

1

J

J

2

2

K

K

2

2

K

K

2

2

K

K

2

2

K

K

3

3

L

L

3

3

L

L

3

3

L

L

3

3

L

L

4

4

M

M

4

4

M

M

4

4

M

M

4

4

M

M

5

5

N

N

5

5

N

N

5

5

N

N

5

5

N

N

6

6

O

O

6

6

O

O

6

6

O

O

6

6

O

O

7

7

P

P

7

7

P

P

7

7

P

P

7

7

P

P

8

8

Q

Q

8

8

Q

Q

8

8

Q

Q

8

8

Q

Q

9

9

R

R

9

9

R

R

9

9

R

R

9

9

R

R

A

A

S

S

A

A

S

S

A

A

S

S

A

A

S

S

B

B

T

T

B

B

T

T

B

B

T

T

B

B

T

T

C

C

U

U

C

C

U

U

C

C

U

U

C

C

U

U

D

D

V

V

D

D

V

V

D

D

V

V

D

D

V

V

E

E

W

W

E

E

W

W

E

E

W

W

E

E

W

W

F

F

X

X

F

F

X

X

F

F

X

X

F

F

X

X

G

G

Y

Y

G

G

Y

Y

G

G

Y

Y

G

G

Y

Y

H

H

Z

Z

H

H

Z

Z

H

H

Z

Z

H

H

Z

Z

Отзывы: