background image

-|Transparent Guide|-

Software

Download the installation file and the manuals from the Autonics website.

  

atMotion

The program allows to manage the motor driver’s parameter setting and monitoring data.

Manual

For proper use of the product, refer to the manuals and be sure to follow the safety 
considerations in the manuals.
Download the manuals from the Autonics website.

Product Components

• 

Product

• 

Instruction manual

• 

Power connector

• 

I/O connector (P I/F, X axis, Y axis)

• 

RS232C comm. cable 1.5 m

• 

USB comm. cable 1 m (PMC-2HSP-USB Series)

• 

RS485 comm. connector (PMC-2HSP-485 Series)

Dimensions

• 

Unit: mm, For the detailed drawings, follow the Autonics website.

64

4

35 mm DIN r

ail

connec

table

35.5

5

90

97

104

Ordering Information

This is only for reference, the actual product does not support all combinations..
For selecting the specified model, follow the Autonics website.  

PMC

-

2HSP

-

❶ Communication type

USB: USB / RS232C
485: RS485 / RS232C

• 

Keep the distance between power cable and signal cable over 10 cm.

• 

It is recommended to use twisted pair shield wire when connecting cables to 

 

CN3, 4, 5 connectors.

 

Ground the shield wires depending on the installation environment.

• 

It is recommended to use the communication cables provided with the product. 

 

(RS232C, USB)

• 

When wiring the RS485 cable, twist pair wire is recommended, and use AWG 24 (0.2mm

2

cable or over.

• 

This unit may be used in the following environments.

 

- Indoors (in the environment condition rated in ‘Specifications’)

 

- Altitude max. 2,000 m

 

- Pollution degree 2

 

- Installation category II

Connectors

  

■ CN1: Power connector

  

■ CN2: RS232C connector

Pin Function

1

24 VDCᜡ

2

GND

1
2

Pin Function

1

TXD

2

RXD

3

GND

4

N·C

5

6

1

···

6

  

■ CN3: Parallel I/F connector

Pin Function

I/O

Description

1

RESET

Input Reset

2

HOME

Input Home search start

3

STROBE

Input Drive start

4

X/JOG Y+

Input X axis designate / Jog Y+

5

Y/JOG Y-

Input Y axis designate / Jog Y-

6

STEPSL0/RUN+/JOG X+ Input Step designate 0 / Run+ / Jog X+

7

STEPSL1/RUN-/JOG X- Input Step designate 1 / Run- / JogX-

8

STEPSL2/SPD0

Input Step designate 2 / Drive speed 

designate 0

9

STEPSL3/SPD1

Input Step designate 3 / Drive speed 

designate 1

10

STEPSL4/JOG

Input Step designate 4 / Jog designate

11

STEPSL5/STOP

Input Step designate 5 / Drive stop

12

MODE0

Input Operation mode designate 0

13

MODE1

Input Operation mode designate 1

14 X DRIVE/END

Output X axis drive / Drive end pulse

15

Y DRIVE/END

Output Y axis drive / Drive end pulse

16 X ERROR

Output X axis error

17

Y ERROR

Output Y axis error

18 GEX

-

GND

19

GEX

-

GND

20

VEX

-

Sensor power output 

 

(24 VDCᜡ, max. 100 mA)

1

3

5

7

9

11

13

15

17

10

2

4

6

8

10

12

14

16

18

20

  

■ CN4, 5: X, Y axis I/O connector

16

14

12

10

8

6

4

2

15

13

11

9

7

5

3

1

Pin Function

I/O

Description

1

nP+P

Output CW+ drive pulse

2

nP+N

Output CW- drive pulse

3

nP-P

Output CCW+ drive pulse

4

nP-N

Output CCW- drive pulse

5

nOUT0

Output General output 0

6

nOUT1

Output General output 1

7

nIN0

Input General input 0

8

nIN1

Input General input 1

9

nSTOP2

Input Encoder Z phase

10

nSTOP1

Input Home

11

nSTOP0

Input Near Home

12

nLMT+

Input + direction limit

13

nLMT-

Input - direction limit

14 EMG

Input Emergency stop 

15

GEX

-

GND

16 VEX

-

Sensor power output 

 

(24 VDCᜡ, max. 100 mA)

  

■ CN6: RS485 connector

3

2
1

Pin Function

Description

1

B (-)

Transmitting / Receiving data

2

A (+)

3

G

Ground when it is required depending on comm. environment.

  

■ Connector specifications

• 

Contact the manufacture for the socket and cable.

Connector

Specifications

Manufacture

CN3

Parallel I/F connector socket

HIF3BA-20D-2.54R

Hirose Electric

CN3

I/O cable (sold separately)

CO20-HP□-L, CO20-HP□-R Autonics

CN4, 5 X, Y axis I/O connector socket

HIF3BA-16D-2.54R

Hirose Electric

Unit Descriptions

07

01

02

04

03

06

05

PMC-2HSP-USB

PMC-2HSP-485

01

02

04

03

06

05

01. 

Power / Status indicator

02. 

Power connector (CN1)

03. 

RS232C comm. connector (CN2)

04. 

Parallel I/F connector (CN3)

05. 

X, Y axis I/O connector (CN4, 5)

06. 

USB / RS485 comm. connector (CN6)

07.  ID select rotary switch