background image

-|Transparent Guide|-

  

MP5W

• 

Power / input 

terminal 

INA

INB

BANK

0 V

0 V

 + 12 V

HOLD / RESET

1

2

3

4

5

6

7

8

9

SOURCE

• A: relay

 quintuple output

HH

H

GO

L

LL

COM

15

10

11

12

13

14

CONTACT OUT:

250 VACᜠ 3 A, 30 VDCᜡ 3 A RESISTIVE LOAD

• 1: relay t

riple output

CONTACT OUT:

250 VACᜠ 3 A, 30 VDCᜡ 3 A RESISTIVE LOAD

10

11

12

13

14

15

H

GO

L

• 

2: NPN open col BCD Dynamic output

MAIN OUT

(NPN OPEN COLLECTOR) 

30 VDCᜡ 30 mA

BCD OUT

(NPN OPEN COLLECTOR) 

30 VDCᜡ 30 mA

2

4

6

8

10 12 14 16

18

20

1

11

3

13

5

15

7

17

9

19

HH

B

D3

COM H

L

GO

D

DOT

COM2

LL

D1

A

D2

C

D4

D0

POL

 

Sub power

+ 24 VDCᜡ

30 mA Max.

0V

•  POL signal turns ON when the display value is a minus (-) value.

• 

4: NPN open col PV 

transmission

 output

MAIN OUT

(NPN OPEN COLLECTOR) 

30 VDCᜡ 30 mA

2

4

6

8

10 12 14 16

18

20

1

11

3

13

5

15

7

17

9

19

HH

COM H

L

GO

LL

Sub power

+ 24 VDCᜡ

30 mA Max.

0V

DC 4 - 20 mA / DC 0 - 20 mA

(Load 500 Ω Max.)

(+)

 (-)

• 

5: PNP open col PV 

transmission

 output

2

4

6

8

10 12 14 16

18

20

1

11

3

13

5

15

7

17

9

19

Sub power

+ 24 VDCᜡ

30 mA Max.

0V

DC 4 - 20 mA / DC 0 - 20 mA

(Load 500 Ω Max.)

 (+)

 (-)

MAIN OUT

(PNP OPEN COLLECTOR)

30 VDCᜡ 30 mA

HH

COM H

L

GO

LL

• 

8: NPN open col RS485 comm.

MAIN OUT

(NPN OPEN COLLECTOR) 

30 VDCᜡ 30 mA

2

4

6

8

10 12 14 16

18

20

1

11

3

13

5

15

7

17

9

19

HH

COM H

L

GO

LL

Sub power

+ 24 VDCᜡ

30 mA Max.

0 V

RS485

B (-)

A (+)

RS485

• 

9: PNP open col RS485 comm.

2

4

6

8

10 12 14 16

18

20

1

11

3

13

5

15

7

17

9

19

Sub power

+ 24 VDCᜡ

30 mA Max.

0 V

RS485

B (-)

A (+)

RS485

MAIN OUT

(PNP OPEN COLLECTOR) 

30 VDCᜡ 30 mA

HH

COM H

L

GO

LL

Communication Interface

  

■ RS485

Comm. protocol

Modbus RTU (16-bit CRC) 

Application standard

Compliance with EIA RS485 

Max. connection

31-unit (address: 1 to 127) 

Comm. synchronous method

Asynchronous

Comm. method

2-wire half duplex 

Comm. distance

≤ 800 m

Comm. speed

2,400 / 4,800 / 9,600 (default) / 19,200 / 38,400 bps

Comm. response time 

5 to 99 ms (default: 20 ms) 

Start bit

1-bit (fixed) 

Data bit

8-bit (fixed) 

Parity bit

None (default), Even, Odd

Stop bit

1-bit, 2-bit (default) 

Specifications

AC voltage

AC / DC voltage

Power supply

100 - 240 VAC ᜠ ± 10 %  

50 / 60 Hz

24 VACᜠ ± 10 % 50 / 60 Hz, 

24 - 48 VDCᜡ ± 10 %

Power consumption

Depending on Series / power supply

MP5S

≤ 7.5 VA 

AC: ≤ 6 VA, DC: ≤ 4.5 W

MP5Y

≤ 9 VA 

AC: ≤ 7 VA, DC: ≤ 6.2 W

MP5W

≤ 15 VA 

AC: ≤ 11 VA, DC: ≤ 7 W

External power supply

≤ 12 VDCᜡ ± 10 % 80 mA

Sub power supply

 01)

≤ 24 VDCᜡ 30 mA 

Memory retention

Number of inputs: 100,000 operations (non-volatile semiconductor memory type)

Relay life cycle

Mechanical:  ≥ 10,000,000 operations (switching frequency 180 operations / min)

Electrical: ≥  100,000 operations (250 VACᜠ 

3 A

, 30 VDCᜡ 

3 A

 resistive 

load) (switching frequency 20 operations / min)

Insulation resistance

≥ 100 MΩ (500 VDCᜡ megger)

Dielectric strength

2,000 VACᜠ 60 Hz for 1 min

Noise immunity 

±2 kV the square wave noise (pulse width: 1㎲) by the noise simulator

Vibration

0.75 mm double amplitude at frequency of 10 to 55 Hz in each X, Y, Z 
direction for 1 hour

Vibration 

(malfunction)

0.5 mm double amplitude at frequency of 10 to 55 Hz in each X, Y, Z 
direction for 10 min

Shock 

300m / s² (

≈ 

30G) in each X, Y, Z direction for 3 times

Shock (malfunction)

100m / s² (

≈ 

30G) in each X, Y, Z direction for 3 times

Ambient temperature

-10 to 50 ℃, storage: -20 to 60 ℃ (no freezing or condensation)

Ambient humidity

35 to 85 %RH, storage: 35 to 85 %RH (no freezing or condensation)

 01)  Only for MP5W

Op

eration mode

Measurement range

Measurement accuracy  

(23 ± 5 ℃)

F1

Frequency / revolutions / speed

0.0005 Hz to 50 kHz

F.S. ± 0.05 % rdg ± 1 digit

F2

Passing speed

F3

Cycle

0.01 to max. of each time 

range

F.S. ± 0.01 % rdg ± 1 digit

F4

Passing time

F5

Time interval

F6

Time differential

F7

Absolute ratio

0.0005 Hz to 50 kHz

F.S. ± 0.05 % rdg ± 1digit

F8

Error ratio

F9

Density

F10

Error

F11

Length measurement 1

0 to 99999

-

F12

Interval

F13

Accumulation

F14

Addition / subtraction

-

individual input

-19999 to 99999

F15

Addition / subtraction

-

phase 

difference input

F16

Length measurement 2

0 to 99999

Series

MP5S

MP5Y

MP5W

Input signal

 01)

Solid state input 1: ≤ 50 kHz (pulse width: ≥ 10 ㎲)

Solid state input 2 

 02)

: ≤ 5 kHz (spulse width: ≥ 100 ㎲)

Contact input: ≤ 45 Hz (contact: 12 VDCᜡ ≥ 5 mA, (pulse width: ≥ 11 ms)

Voltage input

Input impedance: 3.9 kΩ, [H]: 4.5 - 24 VDCᜡ, [L]: 0 - 1 VDCᜡ

No-voltage input

Short-circuit impedance: ≤ 80 Ω, residual voltage: ≤ 1 VDCᜡ, 

open-circuit impedance: ≥ 100 kΩ

Display method

7-segment LED (zero blanking method)

Character size

W 4 × H 8 mm

W 7 × H 14 mm

Prescale

0.0001 × 10

-9 

to 9.9999 × 10

Hysteresis

0 to 9999 

 03)

 

Display cycle

OFF

 04)

, 0.05, 0.5, 1, 2, 4, 8 sec (same as update output cycle)

Display range

-19999 to 99999

Output

Depending on models

Relay

250 VACᜠ 3 A, 30 VDCᜡ 3 A resistive load

NPN / PNP open collector ≤ 30 VDCᜡ 30 mA
BCD Dynamic

NPN open collector ≤ 30 VDCᜡ 30 mA (Dynamic COM cycle (T) = 40 ms)

PV transmission

DC 4 - 20 mA (load: ≤ 500 Ω, resolution: 8,000 divisions) /

DC 0 - 20 mA (load: ≤ 500 Ω, resolution: 10,000 divisions)

RS485 communication

Modbus RTU 

Product components

Product, instruction manual

Bracket

Mounted

× 2

× 2

Unit sticker

× 1

× 1

× 2

Unit weigth (package)

≈ 132 g (≈ 191 g) 

≈ 140 g (≈ 230 g)

≈ 210 g (≈ 334 g)

Approval

ᜢ ᜧ ᜫ

 01)  Standard duty ratio 1:1
 02)  Operation mode F7, F8, F9, F10: ≤ 1 kHz (pulse width: ≥ 500 ㎲)
 03)  The hysteresis setting range varies according to the decimal point setting position.
 04)  Only available operation mode F2, F16

Содержание MP5S Series

Страница 1: ...instruction may result in fire or electric shock 04 Do not connect repair or inspect the unit while connected to a power source Failure to follow this instruction may result in fire or electric shock...

Страница 2: ...Master It is the comprehensive device management program for Autonics products providing parameter setting monitoring and data management Manual For proper use of the product refer to the manuals and...

Страница 3: ...rical 100 000 operations 250 VAC 3 A 30 VDC 3 A resistive load switching frequency 20 operations min Insulation resistance 100 M 500 VDC megger Dielectric strength 2 000 VAC 60 Hz for 1 min Noise immu...

Страница 4: ...each parameter it returns to RUN mode MODE key Saves current setting value and moves to the next parameter key Checks fixed value Changes setting digits key Changes setting values Parameter 0 group P...

Страница 5: ...P0 3 P2 8 L comparative value parameters The set deviation value is saved during Power OFF until it is re set Comparative value setting range 0 0001 to 99999 The setting range is different according...

Страница 6: ...B prescale value of input B Conveyor A Conveyor B MP5 Display value Display unit Error ratio Input A fA fB Input B Hold When the hold signal turns ON the display value is maintained until the display...

Страница 7: ...setting value the output may turn ON OFF frequently and unstably To prevent this hysteresis value is set based on the comparative setting value Comparative value H HH Comparative value L LL A A Outpu...

Страница 8: ...A A S S A A S S B B T T B B T T B B T T B B T T C C U U C C U U C C U U C C U U D D V V D D V V D D V V D D V V E E W W E E W W E E W W E E W W F F X X F F X X F F X X F F X X G G Y Y G G Y Y G G Y Y...

Отзывы: