Autonics LP-A070 Series Скачать руководство пользователя страница 5

LP-A070 Series

V-28

 Unit Description

 Program status LED

LED color

LED status Program status

Green

ON

Run

Green

Flashing

Pause

Red

Flashing

Error

Orange

ON

atLogic debugging

  Serial port (RS232C/RS422)

 

All devices connectable to the product including PC, PLC, serial printer, barcode reader, and dedicated connectors can 

be connected in to both RS232C and RS422 ports.
Port

Pin

Port

Pin

RS232C

RS232C-A 

RS232C-B

9
8
7
6

5
4
3
2
1

D-Sub 9-pin Male

1

Non-Used

RS422

6
7
8
9

1
2
3
4
5

D-Sub 9-pin Female

1

TXD+

2

RXD

2

RXD+

3

TXD

3

Non-Used

4

DTR

4

Non-Used

5

SG

5

SG

6

DSR

6

TXD-

7

Non-Used

7

RXD-

8

Non-Used

8

Non-Used

9

Non-Used

9

Non-Used

  Ethernet port

 

For connecting LAN cable and hub, use direct cable, and for connecting PC directly, use cross cable.

  

USB

Type

USB Host

USB Device

Function

  Transferring/Copying data between 

storage and LP-A070

 Firmware upgrade

 Bar-code reader

 Printer

  Uploading/Downloading a atDesigner project file

 Used as external storage by connecting to PC

USB HOST can cover up to 32GB of external storage. 

It supports only external storage of FAT16 and FAT32 file system.

 

For detailed information about each interface, please refer to 'LP-A Series user manual' and 'GP/LP Communication 

manual'.

LCD Screen

Input

terminal

Output

terminal

Power

LED Run/Stop

Switch

Power

terminal

RS422

or

RS232C-A

RS232C

or

RS232C-B

Ethernet

USB

Device

USB

Host

Mounting slot  

for bracket

Program

status LED

Содержание LP-A070 Series

Страница 1: ...point Output 16 point Simultaneous monitoring of multiple addresses and channels Monitoring device of the connected controllers even without user screen data Multilingual table function switching language of user screen by touching a button Large capacity of memory widen range of UB UW internal device 64MB user screen memory Using user screen drawing program atDesigner More variety functions objec...

Страница 2: ... 25 Insulated resistance Over 100MΩ at 500VDC megger Ground 3rd grounding max 100Ω Noise immunity 0 5kV the square wave noise pulse width 1 by the noise simulator Withstanding voltage 500VAC 50 60Hz for 1 minute Vibration Mechanical 0 75mm amplitude at frequency of 10 to 55Hz for 1 min in each X Y Z direction for 1 hour Malfunction 0 5mm amplitude at frequency of 10 to 55Hz for 1 min in each X Y Z...

Страница 3: ...age 24VDC Insulation method Photocoupler insulation Input resistance Contact X0 to X8 approx 10mA Contact X9 to XF approx 4mA Rated load voltage 24VDC Voltage range 19 2 to 28 8VDC Allowable load voltage range 19 2 to 28 8VDC Input resistance Contact X0 to X8 3 3 Contact X9 to XF 5 6 Max load current 0 1A 1 point 1 6A 1COM Response time 0 5ms Max voltage falling when ON Max 0 2VDC Common method 16...

Страница 4: ...set position when meeting the alarming condition Alarm history Saving data of alarming time device and information when the value of the designated alarm observing device meets the set condition Scheduler Executing a function bit on off reversal work value changing script according to the set condition device cycle Recipe Reading the value of the multiple devices Writing the value to the multiple ...

Страница 5: ...8 Non Used 9 Non Used 9 Non Used Ethernet port For connecting LAN cable and hub use direct cable and for connecting PC directly use cross cable USB Type USB Host USB Device Function Transferring Copying data between storage and LP A070 Firmware upgrade Bar code reader Printer Uploading Downloading a atDesigner project file Used as external storage by connecting to PC USB HOST can cover up to 32GB ...

Страница 6: ...0 0 1 1 0 15 10 4 14 M4 185 134 194 125 28 5 6 5 Check the number of pin on the rear case before wiring Input Output Wiring LP A070 T9D6 7 C5R LP A070 T9D6 7 C5T Input wiring source type Input wiring source type Output wiring sync type Output wiring sync type 24VDC 8 9 A B C D E F 0 1 2 3 4 5 6 7 X0 X1 X2 X3 X4 X5 X6 X7 COM1 COM3 X8 X9 XA XB XC XD XE XF COM2 COM4 24VDC 8 9 A B C D E F 0 1 2 3 4 5 ...

Страница 7: ...tact our service center to replace battery It may cause an explosion or a fire when using improper battery 1 Follow instructions in Cautions during Use Otherwise it may cause unexpected accidents 2 24VDC power supply should be insulated and limited voltage current or Class 2 SELV power supply device 3 Install a power switch or circuit breaker in the easily accessible place for supplying or disconn...

Отзывы: